Checking cables

2004 Volvo C70 2.4 63SECTION Checking cables
Fig 1: Identifying Ignition Off Position
GLL101045Courtesy of VOLVO CARS OF NORTH AMERICA.
  • Ignition off.
  • Remove the door panel from the relevant door according to Door panel .

    Check the circuit for the relevant door as follows:

    For the left front and rear doors: check the cable between VGLA control module #A2 and the relevant gray  lock unit connector terminal 4 for an open-circuit according to Open-circuit, permanent faults . For the right front and rear doors: check the cable between VGLA control module #A15 and the relevant gray  lock unit connector terminal 1 for an open-circuit according to Open-circuit, permanent faults . Also check the gray  lock unit connector for the relevant door for oxidation and contact resistance according to Contact resistance and oxidation .

    Fig 2: Identifying Ohmmeter
    GLL101042Courtesy of VOLVO CARS OF NORTH AMERICA.

Remedy as necessary. Select "Continue". 