Electronic Automatic Temperature Control Module - Retrieve Continuous DTCs

2013 Volkswagen Beetle Base, 2D Hatchback, 2.5L Eng VIN X, Standard TransSECTION Electronic Automatic Temperature Control Module - Retrieve Continuous DTCs
WARNING: This page is about a different car, the 2006 Ford Pickup, 2006 Ford F550 Super Duty, 2006 Ford F450 Super Duty, and 2006 Ford Cab & Chassis. However, it is still accessible from the selected car via links, so may be relevant.

The EATC module will retrieve only continuous (intermittent) DTCs when carrying out this procedure.

  • Retrieval of continuous DTCs can be initiated after cycling the ignition switch from OFF to ON. Normal operation of the climate control system stops when retrieving continuous DTCs.
  • To retrieve continuous DTCs press the OFF and PANEL buttons simultaneously and release, then press the AUTO button within 2 seconds. All vacuum fluorescent segments will be displayed if there are no continuous DTCs present. Continuous DTCs are indicated by the presence of the degrees Celsius symbol (Β°C) on the EATC module display. Record all DTCs displayed.
  • If any DTCs appear, carry out the diagnostic procedure. Refer to the ELECTRONIC AUTOMATIC TEMPERATURE CONTROL MODULE DIAGNOSTIC TROUBLE CODE INDEXΒ  and follow the ACTION for each DTC given.
  • If a condition exists but no DTCs appear, GO to SYMPTOM CHARTΒ  Condition: The EATC System Is Inoperative, Intermittent or Incorrect Operation.
  • To exit and retain all continuous DTCs, press any button except DEFROST. The EATC module will exit the retrieve continuous DTCs mode and retain all continuous DTCs.
  • To exit and clear all continuous DTCs, press the DEFROST button. The EATC module will exit the retrieve continuous DTCs mode and all continuous DTCs will be cleared.
  • Always exit the procedure before powering the system down (system turned OFF). Once the procedure is exited the ignition switch must remain ON for at least 30 seconds to allow the temperature blend door actuators to automatically recalibrate.
  • Continuous DTCs will be deleted after 80 ignition switch ON cycles after the intermittent fault occurs.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.