Signal Circuit Inspection

2010 Kia Rondo LX, 2.7 6SECTION Signal Circuit Inspection
  1. IG "OFF" and disconnect HO2S (B1/S2) connector.
  2. IG "ON" and ENG "OFF"
  3. Measure voltage between terminal 1 of HO2S (B1/S2) harness connector and chassis ground.
    1. Specification:

      Approx. 3.5V - when pumping current is ON

      Approx. 0.45V - when pumping current is OFF

      Fig 1: Measuring Voltage Between Terminal 1 Of HO2S (B1/S2) Harness Connector & Chassis Ground
      G06488803Courtesy of KIA MOTORS AMERICA, INC.
  4. Is the measured voltage within specification?

    YES

    1. Go to "GROUND CIRCUIT INSPECTIONΒ " procedure.

    NO

    1. Repair open in harness, then go to "VERIFICATION OF VEHICLE REPAIRΒ " procedure.
RENDER: 1.0x