Scan Tool Output Controls

2006 Chevrolet SSR AutomaticSECTION Scan Tool Output Controls
Roof and Door Module (RDM)

Scan Tool Output Control Additional Menu Selection(s) Description
Header Latch - The roof/door module (RDM) actuates the header latch to the Latched position when commanded ON. The header latch will actuate to Unlatched when commanded OFF.
Pump Motor Direction - When the Open command is selected, the roof/door module (RDM) will actuate the hydraulic pump motor in the roof open rotational direction for 2 seconds.
When the Close command is selected, the RDM will actuate the hydraulic pump motor in both directions. First in the roof close rotational direction for 2 seconds, then pausing for 3 additional seconds and then activating the pump in the open direction for 2 more seconds.
Roof System - The roof/door module (RDM) operates the roof system through a complete open cycle when commanded Open. When Close is commanded, the RDM operates the roof system through a complete close cycle. The roof Open and Close cycle commands can be terminated at any time by pressing the Exit or Abort key.
Tonneau Latch - The roof/door module (RDM) actuates the tonneau latch to the unlatched position when commanded Off. The RDM actuates the tonneau latch to the latched position when commanded On.
Valve 1 - When commanded On, the roof/door module (RDM) energizes the #1 hydraulic pump solenoid valve to the open position for 5 seconds or until commanded Off. In a partially closed roof situation, the roof panels will retract to their mechanical resting position while the valve is open.
Valve 2 - When commanded On, the roof/door module (RDM) energizes the #2 hydraulic pump solenoid valve to the open position for 5 seconds or until commanded Off. In a partially closed roof situation, the roof panels will retract to their mechanical resting position while the valve is open.
Valve 3 - When commanded On, the roof/door module (RDM) energizes the #3 hydraulic pump solenoid valve to the open position for 5 seconds or until commanded Off. In a partially closed roof situation, the roof panels will retract to their mechanical resting position while the valve is open.
Valve 4 - When commanded On, the roof/door module (RDM) energizes the #4 hydraulic pump solenoid valve to the open position for 5 seconds or until commanded Off. In a partially closed roof situation, the roof panels will retract to their mechanical resting position while the valve is open.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.