HOMESERVICE MANUALSCHEVROLET2006SSR AUTOMATICREPAIR AND DIAGNOSISBODY & FRAMESUN ROOF/T-TOP/CONVERTIBLE TOPPOWER ROOF SYSTEMDIAGNOSTIC INFORMATION AND PROCEDURESSCAN TOOL DATA LIST
2006 Chevrolet SSR Automatic
Scan Tool Data List
2006 Chevrolet SSR AutomaticSECTION Scan Tool Data List
Roof and Door Module (RDM)
| Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
|---|---|---|---|
| Operating Conditions: Ignition ON, Vehicle in PARK, Folding Top Closed, Windows Closed, Rear Compartment Closed | |||
| Battery Voltage Signal 1 | Data | Volts | B+ |
| Battery Voltage Signal 2 | Data | Volts | B+ |
| 8 Digit GM Part Number | ID Information | Numerical | XXXX |
| Front Tonneau Status | Inputs | Active/Retracted/ Extended/ Invalid | Retracted |
| Folding Top Cyl. Extended Sen. | Data | Volts | 0.35-1.33 Volts |
| Folding Top Cyl. Retracted Sen. | Data | Volts | 2.30-4.04 Volts |
| Header Latch Motor | Data | Amps | 0.00 amps |
| Header Over Center Latch Switch | Inputs | Active / Inactive | Active |
| Header Latch Switch | Inputs | Transition / Released / Latched / Invalid | Latched |
| Header Motor Command | Outputs | Idle / Unlatched/ Latched/ Invalid | Idle |
| Ignition On | Data | Yes / No | Yes |
| Ignition Voltage Signal | Data | Volts | Varies |
| Julian Date of Build | ID Information | Numerical | XXXX |
| Module Over Current Detected | Inputs | Yes / No | No |
| Pump Motor Command | Outputs | Idle / Forward/ Reverse/ Invalid | Idle |
| Rear Compartment Lid Ajar | Inputs | Ajar / Closed | Closed |
| Roof Close Cycle Counter | Data | Counts | varies |
| Roof Dowel Pin Switch | Inputs | Engaged/Disengaged | Engaged |
| Roof Open Cycle Counter | Data | Counts | varies |
| Roof Panel State | Roof System Status | Roof Panel Position Unknown / Roof Up and Latched / Roof Up and Partially Latched / Roof Up and Unlatched / Roof Up and Dowel Pin Not Engaged / Roof Down / Both Roof cylinder up and Down Hall Sensors On | Roof Up and Latched |
| Roof System Status | Roof System Status | Roof Closed / Opening Windows / Unlatch Tonneau Panel / Overdrive Latch / Pause for Pump to Stop / Open Tonneau Panel / Overdrive Tonneau / Raise Flipper Door / Overdrive Flipper / Release Header Latch / Lower Top panels / Close Tonneau Pane / Latch Tonneau Panel / Roof Opened / Opening Windows / Unlatch Tonneau Panel / Overdrive Latch / Pause for Pump to Stop / Open Tonneau Panel / Overdrive Tonneau / Raise Top Panels / Retract Header Latch / Lower Flipper Door / Overdrive Flipper / Close Tonneau Pane / Latch Tonneau Panel / Close Windows | Roof Closed |
| Shift Lock Solenoid Status | Inputs | Lock/Unlock | Lock |
| Software Part Number | ID Information | Numerical | XXXX |
| Storage Latch Cyl. Retracted Left/Right Sen. | Data | Volts | 2.30-4.04 Volts |
| Storage Lid Closed Left/Right Sensors | Data | Volts | 0.82-1.80 Volts |
| Storage Lid Cyl. Extended Sen. | Data | Volts | 2.30-4.04 Volts |
| Storage Lid Ext. Panel Extended Sen. | Data | Volts | 2.30-4.04 Volts |
| Storage Lid Ext. Panel Retracted Sen. | Data | Volts | 0.35-1.33 Volts |
| Tonneau Cylinder Switch | Inputs | Active / Inactive | Inactive |
| Tonneau Latch Switch | Inputs | Latched / Unlatched | Latched |
| Tonneau Panel State | Roof System Status | Tonneau Panel Position Unknown / Tonneau Panel Down and Latched / Tonneau Panel Down and Partially Latched / Tonneau Panel Down and Unlatched / Tonneau Panel Up / Both Tonneau Up and Down Hall Sensors Active | Tonneau Panel Down and Latched |
| Tonneau Safety Switch | Inputs | Latched / Unlatched | Latched |
| Tonneau Striker Switch | Inputs | Active / Inactive | Active |
| Top Control Switch | Inputs | Idle / Top Open / Top Closed | Idle |
| Top Cylinder Switch | Inputs | Active / Extended / Retracted/ Invalid | Extended |
| Valve 1 Command | Outputs | Active / Inactive | Inactive |
| Valve 2 Command | Outputs | Active / Inactive | Inactive |
| Valve 3 Command | Outputs | Active / Inactive | Inactive |
| Valve 4 Command | Outputs | Active / Inactive | Inactive |
| Year Module Built | ID Information | Numerical | XXXX |
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.