2C4F

2006 BMW X5 (E53) V8-4.8L (N62)SECTION 2C4F
2C4F - P2626

Information saved in
DME

Fault code
2C4F - P2626

Fault text
Oxygen sensor before catalytic converter, calibration cable

Fault description
O2 Sensor Pumping Current Trim Circuit/Open (Bank 1
Sensor 1)

Condition for fault identification
Test condition:
Monitoring on disconnected calibration wire (IA);
Diagnosis conditions:
- Trailing-throttle overrun abort present for at least 2 sec.
- Voltage at CJ125 > 4.8 V
- O2 sensor heated to adequate temperature
- Exhaust-gas temp. (model) before cat. < 750 οΏ½C
Terminal condition: Engine running
Voltage condition:
battery voltage<11V oder Ubatt > 16 volts

Condition for fault memory entry
Fault monitoring criterion must remain present over 1 sec.

Action in service
Check plug / wiring harness / O2 wiring, otherwise replace
O2 sensor

Fault effect and breakdown warning


Driver information
Warning light:
MIL on (in 2nd driving cycle);

Service instruction
none
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.