6 - Identifying A Control Module In the CAN Network

2003 Volvo V70 2.4 L5-2.4L VIN 61 B5244SSECTION 6 - Identifying A Control Module In the CAN Network



Identifying A Control Module In The CAN Network







- Connect the battery.
- ignition on.

NOTE: When disconnecting/connecting the battery lead.

If the load on the CAN network is too high, this may be due to a control module sending faulty messages on the CAN network (known as a disruptive control module). The fault may also be due to an intermittent short-circuit to supply voltage or ground in one of the CAN cables. This results in the control modules on the CAN network starting to send faulty messages. The faults can occur without a diagnostic trouble code (DTC) being stored by the control modules. The voltage can be measured between the CAN cables in order to check the load on the CAN network.

Connect a voltmeter between the CAN cables. If the communication on the network is correct, the average voltage value should be approximately 0.5 V (0.4 V to 0.6 V). If there is a fault in the communication, the voltage reading will be approximately 0.7 V or higher.

In order to identify from which control module the faulty communication is being transmitted, cut the supply voltage to one control module at a time and check the voltage in the CAN cables again.

The easiest way to cut the supply voltage is to remove a fuse. Repeat until the voltage between the CAN cables drops to approximately 0.5 V.

HINT: When the probable faulty control module has been identified, connect and disconnect the supply voltage to the control module a number of times to verify that the fault appears and disappears.

NOTE: Do not cut the power to the central electronic module (OEM) unless it is the last control module left to check.

The control module that is communicating incorrectly must be replaced.

Remedy as necessary.

NOTE: Following a fault involving "disruptive" control modules, other modules may remain in "Limp-Home mode" even after switching the ignition off and on a number of times. To remedy this, disconnect and reconnect the battery negative terminal to restore the control modules to normal function.

Was a fault detected?

YES: (See Verification) 9 - Verification
NO: (See Downloading New Software) 6 - Downloading New Software
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.