2000 Volvo S40FACTORY OEM SERVICE PROCEDURE

Control Module For The Blower Fan Motor, Installing (87-0025)

Publication date: 2004-02-01
Reference number: 87-0025

CONTROL MODULE FOR THE BLOWER FAN MOTOR, INSTALLING

CONTROL MODULE FOR THE BLOWER FAN MOTOR, INSTALLING

TECHNICAL SERVICE BULLETIN

Reference Number(s): 87-0025, Date of Issue:  February, 2004
VOLVO: S40 (-04)/V40 2000-
SECTION: 8
GROUP: 87
NO.: 0025

BACKGROUND

To minimize the risk of unpleasant odors from occurring in the heating/ventilation system, a kit can be installed that activates the blower fan for set periods after the ignition is switched off.

IMPORTANT: This control module may not be used if the vehicle is equipped with an ultra sonic alarm.
MATERIALS

Description Quantity Part No.
Kit 1 30623435
Cable Tie 10 983750
SPECIAL TOOLS

Description Special Tool Bulletin # Part No.
Terminal Removal tool From Terminal repair kit 951 2946 or 951 2647 (STB 95) 951 2636 Blue

CLIMATE CONTROL UNIT

Control module blower fan motor, installing 

  1. System background
    NOTE: The system stops functioning if the battery voltage falls below 12.5 Volts. This is to prevent the battery from discharging.

    To activate the system, the ambient temperature must be at least 16°C. The system activation is dependent upon ambient temperature and not air conditioning usage.

    The fan runs at full speed for 10 seconds, starting 30 seconds after the ignition is turned off.

    After 10 minutes the fan starts again and runs for 10 seconds.

    NOTE: This cycle is repeated for approximately two hours.

    During this time, the fan motor will run at full speed for a maximum of two minutes in total.

    If the engine is started during this time, the start system is always reset.

  2. Preparations (see Fig 1 )

    Make a note of the radio code.

    Switch off the ignition.

    Disconnect the battery negative lead.

    Remove:

    • the soundproofing panels on the driver and passenger sides
    • the side panels on the center console.
    NOTE: Set the blower fan switch to 0.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.