Engine/Motor Control Module --, 2022 MY
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| else pending fault (offset or fuel trim monitor) from previous DCY | ||||||||||||
| O2S rear control loop (i- part) (Referenced) | active | |||||||||||
| for time | >= 30.0 | [s] | ||||||||||
| O2S Front Offset Adaptation (Referenced) | fulfilled | |||||||||||
| or | ||||||||||||
| case 2: pending fault fuel trim monitor from previous DCY | ||||||||||||
| O2S rear control loop (i-part) (Referenced) | active | |||||||||||
| for time | >= 30.0 | [s] | ||||||||||
| O2S Front Offset Adaptation (Referenced) | fulfilled | |||||||||||
| additional conditions: pending fault fuel trim and O2S front offset monitor from previous DCY | ||||||||||||
| O2S rear control loop (i-part) (Referenced) | active | |||||||||||
| for time | >= 65.0 | [s] | ||||||||||
| additional conditions: soot mass conditions | ||||||||||||
| soot mass conditions (Referenced) | not calibrated | |||||||||||
| Oxygen Sensor (O2S) front | P0132 - O2 Sensor Circuit High Voltage Bank 1 Sensor 1 | circuit high (aborted RAM check) over voltage check @ sensor lines | voltage @ ground resistor | > 4.0 | [V] | battery voltage | >= 10.70 | [V] | 5 [events] continuous | 2 DCY |
|
|
| or | or | |||||||||||
| voltage @ sensor pump current, virtual ground, trim current or nernst current | > 9.1...10.3 | [V] | battery voltage | < 10.70 | [V] | |||||||
| for time | < 1.5 | [s] | ||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||
| conditions above must be fulfilled | ||||||||||||
| for time | >= 0.1 | [s] | ||||||||||
| circuit high (idle mode) over voltage check @ sensor lines | voltage @ sensor pump current, virtual ground, trim current or nernst current | > 9.1...10.3 | [V] | battery voltage | >= 10.70 | [V] | 5 [events] multiple | 2 DCY | ||||
| or | ||||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||
| for time | < 1.5 | [s] | ||||||||||
| battery voltage | > 9.80; <= 16.10 | [V] | ||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||
| conditions above must be fulfilled | ||||||||||||
| for time | >= 0.1 | [s] | ||||||||||
| circuit high (switch-on or warm- up mode) voltage check @ sensor lines | voltage drop | > 0.20 | [V] | battery voltage | >= 10.70 | [V] | 5 [events] multiple | 2 DCY | ||||
| or | ||||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||
| for time | < 1.5 | [s] | ||||||||||
| battery voltage | > 9.80; <= 16.10 | [V] | ||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||
| conditions above must be fulfilled | ||||||||||||
| for time | >= 0.1 | [s] | ||||||||||
| circuit high (aborted RAM check @ warm-up mode) over voltage @ sensor lines | voltage @ sensor pump current, virtual ground, trim current or nernst current | > 9.1...10.3 | [V] | battery voltage | >= 10.70 | [V] | 5 [events] multiple | 2 DCY | ||||
| or | [s] | |||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | battery voltage | < 10.70 | [V] | |||||||
| no open load detected within | for time | < 1.5 | [s] | |||||||||
| measured calibration resistance @pump cell | >= 164.00 | [Ohm] | battery voltage | > 9.80; <= 16.10 | [V] | |||||||
| measured calibration resistance @ nernst cell | >= 164.00 | [Ohm] | battery voltage | <= 16.10 | [V] | |||||||
| conditions above must be fulfilled | ||||||||||||
| for time | >= 0.1 | [s] | ||||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Oxygen Sensor (O2S) front | P0152 - O2 Sensor Circuit High Voltage Bank 2 Sensor 1 | circuit high (aborted RAM check) overvoltage check @ sensor lines | voltage @ ground resistor | > 4.0 | [V] | battery voltage | not calibrated | [V] | 5 [events] continuous | 2 DCY |
|
|
| or | or | |||||||||||
| voltage @ sensor pump current, virtual ground, trim current or nernst current | > 9.1...10.3 | [V] | battery voltage | < 10.70 | [V] | |||||||
| for time | < 1.5 | [s] | ||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||
| conditions above must be fulfilled | ||||||||||||
| for time | >= 0.1 | [s] | ||||||||||
| circuit high (idle mode) overvoltage check @ sensor lines | voltage @ sensor pump current, virtual ground, trim current or nernst current | > 9.1...10.3 | [V] | battery voltage | not calibrated | [V] | 5 [events] multiple | 2 DCY | ||||
| or | ||||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||
| for time | < 1.5 | [s] | ||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||
| conditions above must be fulfilled | ||||||||||||
| for time | >= 0.1 | [s] | ||||||||||
| circuit high (switch-on or warm- up mode) voltage check @ sensor lines | voltage drop | > 0.2 | [V] | battery voltage | not calibrated | [V] | 5 [events] multiple | 2 DCY | ||||
| or | ||||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||
| for time | < 1.50 | [V] | ||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||
| conditions above must be fulfilled | ||||||||||||
| for time | >= 0.1 | [s] | ||||||||||
| circuit high (aborted RAM check @ warm-up mode) overvoltage @ sensor lines | voltage @ sensor pump current, virtualground, trim current or nernst current | > 9.1...10.3 | [V] | battery voltage | not calibrated | [V] | 5 [events] multiple | 2 DCY | ||||
| or | or | |||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | battery voltage | < 10.70 | [V] | |||||||
| no open load detected within | for time | < 1.5 | [s] | |||||||||
| measured calibration resistance @pump cell | >= 164.00 | [Ohm] | battery voltage | > 9.80 | [V] | |||||||
| measured calibration resistance @ nernst cell | >= 164.00 | [Ohm] | battery voltage | <= 16.10 | [V] | |||||||
| conditions above must be fulfilled | ||||||||||||
| for time | >= 0.1 | [s] | ||||||||||
| Oxygen Sensor (O2S) front | P2237 - O2 Sensor Positive Current Control Circuit/Open Bank 1 Sensor 1 | open circuit (aborted RAM check) circuit continuity check @ normal mode | ASIC operation | aborted | battery voltage | >= 10.70 | [V] | 5 [events] continuous | 2 DCY |
|
||
| or | ||||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||
| for time | < 1.5 | [s] | ||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||
| conditions above must be fulfilled | ||||||||||||
| for time | >= 0.1 | [s] | ||||||||||
| O2S heating up is finished | ||||||||||||
| O2S heating up phase | completed | |||||||||||
| or | ||||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | ||||||||||
| open circuit (warm-up mode) nernst and pump cell transition check | measured calibration resistance @ pumpcell | < 164.00 | [Ohm] | battery voltage | >= 10.70 | [V] | 5 [events] multiple | 2 DCY | ||||
| measured calibration resistance @ nernst cell | >= 164.00 | [Ohm] | or | |||||||||
| battery voltage | < 10.70 | [V] | ||||||||||
| for time | < 1.5 | [s] | ||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||
| conditions above must be fulfilled | ||||||||||||
| for time | >= 0.1 | [s] | ||||||||||
| O2S heating up is finished | ||||||||||||
| O2S heating up phase | completed | |||||||||||
| or | ||||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | ||||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Oxygen Sensor (O2S) front | P2240 - O2 Sensor Positive Current Control Circuit/Open Bank 2 Sensor 1 | open circuit (aborted RAM check) circuit continuity check @ normal mode | ASIC operation | aborted | battery voltage | not calibrated | [V] | 5 [events] continuous | 2 DCY |
|
|
| or | |||||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| or | |||||||||||
| battery voltage | > 9.80 | [V] | |||||||||
| battery voltage | <= 16.10 | [V] | |||||||||
| conditions above must be fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| O2S heating up phase | completed | ||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | |||||||||
| open circuit (warm-up mode) nernst and pump cell transition check | measured calibration resistance @ pumpcell | < 164.00 | [Ohm] | battery voltage | not calibrated | [V] | 5 [events] multiple | 2 DCY | |||
| measured calibration resistance @ nernst cell | >= 164.00 | [Ohm] | or | ||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| or | |||||||||||
| battery voltage | > 9.80 | [V] | |||||||||
| battery voltage | <= 16.10 | [V] | |||||||||
| conditions above must be fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| O2S heating up phase | completed | ||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | |||||||||
| Oxygen Sensor (O2S) front | P2243 - O2 Sensor Reference Voltage Circuit/Open Bank 1 Sensor 1 | open circuit (aborted RAM check) circuit continuity check @ normal mode | ASIC operation | aborted | battery voltage | >= 10.70 | [V] | 5 [events] continuous | 2 DCY |
|
|
| or | |||||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80 | [V] | |||||||||
| battery voltage | <= 16.10 | [V] | |||||||||
| conditions above must be fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| O2S heating up is finished | |||||||||||
| O2S heating up phase | completed | ||||||||||
| or | |||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | |||||||||
| open circuit (not idle mode) circuit continuity check @ pump current operation | nernst voltage | > 1.80 | [V] | battery voltage | >= 10.70 | [V] | 5 [events] continuous | 2 DCY | |||
| or | |||||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80 | [V] | |||||||||
| battery voltage | <= 16.10 | [V] | |||||||||
| conditions above must be fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| O2S heating up is finished | |||||||||||
| O2S heating up phase | completed | ||||||||||
| or | |||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | |||||||||
| open circuit (warm-up mode) nernst and pump cell transition check | measured calibration resistance @ pumpcell | >= 164.00 | [Ohm] | battery voltage | >= 10.70 | [V] | 5 [events] multiple | 2 DCY | |||
| measured calibration resistance @ nernst cell | < 164.00 | [Ohm] | or | ||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80 | [V] | |||||||||
| battery voltage | <= 16.10 | [V] | |||||||||
| conditions above must be fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| O2S heating up is finished | |||||||||||
| O2S heating up phase | completed | ||||||||||
| or | |||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | |||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| open circuit (aborted RAM check @ warm-up mode) circuit continuity check @ warm-up mode | ASIC operation | aborted | battery voltage | >= 10.70 | [V] | 5 [events] multiple | 2 DCY | |||||||
| or | ||||||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||||
| for time | < 1.5 | [s] | ||||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||||
| conditions above must be fulfilled | ||||||||||||||
| for time | >= 0.1 | [s] | ||||||||||||
| O2S heating up is finished | ||||||||||||||
| O2S heating up phase | completed | |||||||||||||
| or | ||||||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | ||||||||||||
| Oxygen Sensor (O2S) front | P2247 - O2 Sensor Reference Voltage Circuit/Open Bank 2 Sensor 1 | open circuit (aborted RAM check) circuit continuity check @ normal mode | ASIC operation | aborted | battery voltage | not calibrated | [V] | 5 [events] continuous | 2 DCY |
|
||||
| or | ||||||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||||
| for time | < 1.5 | [s] | ||||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||||
| conditions above must be fulfilled | ||||||||||||||
| for time | >= 0.1 | [s] | ||||||||||||
| O2S heating up phase | completed | |||||||||||||
| or | ||||||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | ||||||||||||
| open circuit (not idle mode) circuit continuity check @ pump current operation | nernst voltage | > 1.80 | [V] | battery voltage | not calibrated | [V] | 5 [events] multiple | 2 DCY | ||||||
| or | ||||||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||||
| for time | < 1.5 | [s] | ||||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||||
| conditions above must be fulfilled | ||||||||||||||
| for time | >= 0.1 | [s] | ||||||||||||
| O2S heating up phase | completed | |||||||||||||
| or | ||||||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | ||||||||||||
| open circuit (warm-up mode) nernst and pump cell transition check | measured calibration resistance @ pump cell | >= 164.00 | [Ohm] | battery voltage | not calibrated | [V] | 5 [events] multiple | 2 DCY | ||||||
| measured calibration resistance @ nernst cell | < 164.00 | [Ohm] | or | |||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||||
| for time | < 1.5 | [s] | ||||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||||
| conditions above must be fulfilled | ||||||||||||||
| for time | >= 0.1 | [s] | ||||||||||||
| O2S heating up phase | completed | |||||||||||||
| or | ||||||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | ||||||||||||
| open circuit (aborted RAM check @ warm-up mode) circuit continuity check @ warm-up mode | ASIC operation | aborted | battery voltage | not calibrated | [V] | 5 [events] multiple | 2 DCY | |||||||
| or | ||||||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||||
| for time | < 1.5 | [s] | ||||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||||
| conditions above must be fulfilled | ||||||||||||||
| for time | >= 0.1 | [s] | ||||||||||||
| O2S heating up phase | completed | |||||||||||||
| or | ||||||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | ||||||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Oxygen Sensor (O2S) front | P2251 - O2 Sensor Negative Current Control Circuit/Open Bank 1 Sensor 1 | open circuit (normal ASIC operation) circuit continuity check @ normal mode | O2S front heater control deviation | >= 65.0 | [K] | battery voltage | >= 10.70 | [V] | 5 [events] continuous | 2 DCY |
|
|||
| within voltage pump cell | < -0.40 | [V] | or | |||||||||||
| for time | >= 0.1 | [s] | battery voltage | < 10.70 | [V] | |||||||||
| or | for time | < 1.5 | [s] | |||||||||||
| O2S front heater control deviation | < 65.0 | [K] | battery voltage | > 9.80 | [V] | |||||||||
| within voltage pump cell | < -0.25 | [V] | battery voltage | <= 16.10 | [V] | |||||||||
| for time | >= 0.1 | [s] | conditions above must be fulfilled | |||||||||||
| for time | >= 0.1 | [s] | ||||||||||||
| O2S heating up is finished | ||||||||||||||
| O2S heating up phase | completed | |||||||||||||
| or | ||||||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | ||||||||||||
| open circuit (aborted RAM check) circuit continuity check @ normal mode | ASIC operation | aborted | battery voltage | >= 10.70 | [V] | 5 [events] continuous | 2 DCY | |||||||
| or | ||||||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||||
| for time | < 1.5 | [s] | ||||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||||
| conditions above must be fulfilled | ||||||||||||||
| for time | >= 0.1 | [s] | ||||||||||||
| O2S heating up is finished | ||||||||||||||
| O2S heating up phase | completed | |||||||||||||
| or | ||||||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | ||||||||||||
| open circuit (warm-up mode) nernst and pump cell transition check | measured calibration resistance @ pumpcell | < 164.00 | [Ohm] | battery voltage | >= 10.70 | [V] | 5 [events] multiple | 2 DCY | ||||||
| measured calibration resistance @ nernst cell | < 164.00 | [Ohm] | or | |||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||||
| for time | < 1.5 | [s] | ||||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||||
| conditions above must be fulfilled | ||||||||||||||
| for time | >= 0.1 | [s] | ||||||||||||
| O2S heating up is finished | ||||||||||||||
| O2S heating up phase | completed | |||||||||||||
| or | ||||||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | ||||||||||||
| open circuit (aborted RAM check @ warm-up mode) circuit continuity check @ warm-up mode | ASIC operation | aborted | battery voltage | >= 10.70 | [V] | 5 [events] multiple | 2 DCY | |||||||
| voltage @ RE /IPE /APE /MES | > 9.1...10.3 | [V] | or | |||||||||||
| measured calibration resistance at pump cell | < 164.00 | [Ohm] | battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | ||||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||||
| conditions above must be fulfilled | ||||||||||||||
| for time | >= 0.1 | [s] | ||||||||||||
| O2S heating up is finished | ||||||||||||||
| O2S heating up phase | completed | |||||||||||||
| or | ||||||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | ||||||||||||
| Oxygen Sensor (O2S) front | P2254 - O2 Sensor Negative Current Control Circuit/Open Bank 2 Sensor 1 | open circuit (normal ASIC operation) circuit continuity check @ normal mode | O2S front heater control deviation | >= 65.0 | [K] | battery voltage | not calibrated | [V] | 5 [events] continuous | 2 DCY |
|
|||
| within voltage pump cell | < -0.40 | [V] | or | |||||||||||
| for time | >= 0.1 | [s] | battery voltage | < 10.70 | [V] | |||||||||
| or | for time | < 1.5 | [s] | |||||||||||
| O2S front heater control deviation | < 65.0 | [K] | battery voltage | > 9.80 | [V] | |||||||||
| within voltage pump cell | < -0.25 | [V] | battery voltage | <= 16.10 | [V] | |||||||||
| for time | >= 0.1 | [s] | conditions above must be fulfilled | |||||||||||
| for time | >= 0.1 | [s] | ||||||||||||
| O2S heating up phase | completed | |||||||||||||
| or | ||||||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | ||||||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| open circuit (aborted RAM check) circuit continuity check @ normal mode | ASIC operation | aborted | [events] | battery voltage | not calibrated | [V] | 5 [events] continuous | 2 DCY | ||||||
| or | ||||||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||||
| for time | < 1.5 | [s] | ||||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||||
| conditions above must be fulfilled | ||||||||||||||
| for time | >= 0.1 | [s] | ||||||||||||
| O2S heating up phase | completed | |||||||||||||
| or | ||||||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | ||||||||||||
| open circuit (warm-up mode) nernst and pump cell transition check | measured calibration resistance @ pumpcell | < 164.00 | [Ohm] | battery voltage | not calibrated | [V] | 5 [events] multiple | 2 DCY | ||||||
| measured calibration resistance @ nernst cell | < 164.00 | [Ohm] | or | |||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||||
| for time | < 1.5 | [s] | ||||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||||
| conditions above must be fulfilled | ||||||||||||||
| for time | >= 0.1 | [s] | ||||||||||||
| O2S heating up phase | completed | |||||||||||||
| or | ||||||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | ||||||||||||
| open circuit (aborted RAM check @ warm-up mode) circuit continuity check @ warm-up mode | ASIC operation | aborted | battery voltage | not calibrated | [V] | 5 [events] multiple | 2 DCY | |||||||
| or | ||||||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||||
| for time | < 1.5 | |||||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||||
| conditions above must be fulfilled | ||||||||||||||
| for time | >= 0.1 | [s] | ||||||||||||
| O2S heating up phase | completed | |||||||||||||
| or | ||||||||||||||
| O2S ceramic temperature | > 634.0 | [°C] | ||||||||||||
| Oxygen Sensor (O2S) front | P0133 - O2 Sensor Circuit Slow Response Bank 1 Sensor 1 | intrusive monitor O2S signal dynamic check | delayed response (arithmetic filter) | conditions for dynamic fault suspicion evaluation | 20 [s]once / DCY | 1 DCY |
|
|||||||
| time @ lean to rich transition | not calibrated | [s] | dev. expected vs. measured lambda (high quality model) | >= 128.00 | [-] | |||||||||
| or | or | |||||||||||||
| time @ rich to lean transition | not calibrated | [s] | dev. expected vs. measured lambda (low quality model) | >= 128.00 | [-] | |||||||||
| slow transition (arithmetic filter) | monitor entry conditions | |||||||||||||
| time @ lean to rich transition | not calibrated | [s] | enable conditions for active lambda stimulation (Referenced) | checked | ||||||||||
| or | conditions for avoiding controller oscillations | |||||||||||||
| time @ rich to lean transition | not calibrated | [s] | enable conditions for online identification (Referenced) | checked | ||||||||||
| or | for arithmetic average value calculation | |||||||||||||
| delayed response (EWMA filter) | number of checks required for valid result | not calibrated | [-] | |||||||||||
| time @ lean to rich transition | > 0.3 | [s] | for EWMA-filter: | |||||||||||
| or | K-factor | 0.35 | [-] | |||||||||||
| time @ rich to lean transition | > 0.3 | [s] | minimum number of tests per DCY required | 1 | [-] | |||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| slow transition (EWMA filter) | step change detection will initiate multiple tests per DCY conditions for step change detection (delayed response) | ||||||||||
| time @ lean to rich transition | > 0.3 | [s] | dev. new measured vs. old EWMA filtered value (delayed response) | > 0.3 | [s] | ||||||
| or | maximum tolerance to confirm filtered value (delayed response) | 0.05 | [s] | ||||||||
| time @ rich to lean transition | > 0.3 | [s] | or | ||||||||
| delayed response (while avoiding controller oscillations) | step change detection will initiate multiple tests per DCY conditions for step change detection (transition response) | ||||||||||
| adaptation time @ lean to rich transition | > 1.0 | [s] | dev. new measured vs. old EWMA filtered value (transition response) | > 0.3 | [s] | ||||||
| or | maximum tolerance to confirm filtered value (transition response) | 0.05 | [s] | ||||||||
| adaptation time @ rich to lean transition | > 1.0 | [s] | further calculation conditions for EWMA filter | ||||||||
| slow transition (while avoiding controller | number of checks forconfirmation | 5 | [-] | ||||||||
| oscillations) | |||||||||||
| adaptation time @ lean to richtransition | > 1.0 | [s] | initial value of filtered value | 0 | [-] | ||||||
| or | maximum number of checks per driving cycle | 5 | [-] | ||||||||
| adaptation time @ rich to lean transition | > 1.0 | [s] | |||||||||
| delayed response and slow transition (while avoiding controller oscillations) | |||||||||||
| sum of adaptation times (delay and slow response) @ lean to rich transition | > 1.5 | [s] | |||||||||
| or | |||||||||||
| sum of adaptation times (delay and slow response) @ rich to lean transition | > 1.5 | [s] | |||||||||
| Oxygen Sensor (O2S) front | P0153 - O2 Sensor Circuit Slow Response Bank 2 Sensor 1 | intrusive monitor O2S signal dynamic check | delayed response (arithmetic filter) | conditions for dynamic fault suspicion evaluation | 20 [s] once / DCY | 1 DCY |
|
||||
| time @ lean to rich transition | not calibrated | [s] | dev. expected vs. measured lambda (high quality model) | >= 128.00 | [-] | ||||||
| or | or | ||||||||||
| time @ rich to lean transition | not calibrated | [s] | dev. expected vs. measured lambda (low quality model) | >= 128.00 | [-] | ||||||
| slow transition (arithmetic filter) | monitor entry conditions | ||||||||||
| time @ lean to rich transition | not calibrated | [s] | enable conditions for active lambda stimulation (Referenced) | checked | |||||||
| or | conditions for avoiding controller oscillations | ||||||||||
| time @ rich to lean transition | not calibrated | [s] | enable conditions for online identification (Referenced) | checked | |||||||
| or | for arithmetic average value calculation | ||||||||||
| delayed response (EWMA filter) | number of checks required for valid result | not calibrated | [-] | ||||||||
| time @ lean to rich transition | > 0.3 | [s] | for EWMA-filter: | ||||||||
| or | K-factor | 0.35 | [-] | ||||||||
| time @ rich to lean transition | > 0.3 | [s] | minimum number of tests per DCY required | 1 | [-] | ||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| slow transition (EWMA filter) | step change detection will initiate multiple tests per DCY conditions for step change detection (delayed response) | |||||||||||
| time @ lean to rich transition | > 0.3 | [s] | dev. new measured vs. old EWMA filtered value (delayed response) | > 0.3 | [s] | |||||||
| or | maximum tolerance to confirm filtered value (delayed response) | 0.1 | [s] | |||||||||
| time @ rich to lean transition | > 0.3 | [s] | or | |||||||||
| delayed response (while avoiding controller oscillations) | step change detection will initiate multiple tests per DCY conditions for step change detection (transition response) | |||||||||||
| adaptation time @ lean to rich transition | > 1.0 | [s] | dev. new measured vs. old EWMA filtered value (transition response) | > 0.3 | [s] | |||||||
| or | maximum tolerance to confirm filtered value (transition response) | 0.1 | [s] | |||||||||
| adaptation time @ rich to lean transition | > 1.0 | [s] | further calculation conditions for EWMA filter | |||||||||
| slow transition (while avoiding controller | number of checks forconfirmation | 5 | [-] | |||||||||
| oscillations) | ||||||||||||
| adaptation time @ lean to richtransition | > 1.0 | [s] | initial value of filtered value | 0 | [-] | |||||||
| or | maximum number of checks per driving cycle | 5 | [-] | |||||||||
| adaptation time @ rich to lean transition | > 1.0 | [s] | ||||||||||
| delayed response and slow transition (while avoiding controller oscillations) | ||||||||||||
| sum of adaptation times (delay and slow response) @ lean to rich transition | > 1.5 | [s] | ||||||||||
| or | ||||||||||||
| sum of adaptation times (delay and slow response) @ rich to lean transition | > 1.5 | [s] | ||||||||||
| Oxygen Sensor (O2S) front | P0606 - ECM/PCM Processor | electrical check | SPI communication | error detected | battery voltage | not calibrated | [V] | 150 [events] continuous | 2 DCY |
|
||
| or | ||||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||
| for time | < 1.5 | [s] | ||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||
| conditions above must be fulfilled | ||||||||||||
| for time | >= 0.1 | [s] | ||||||||||
| Oxygen Sensor (O2S) front | P0606 - ECM/PCM Processor | electrical check | SPI communication | error detected | [events] | battery voltage | not calibrated | [V] | 0.5 [s] continuous | 2 DCY |
|
|
| for number of events | 150 | or | ||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||
| for time | < 1.5 | [s] | ||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||
| conditions above must be fulfilled | ||||||||||||
| for time | >= 0.1 | [s] | ||||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Oxygen Sensor (O2S) front | P2626 - O2 Sensor Pumping Current Trim Circuit/Open Bank 1 Sensor 1 | open circuit | calculated calibration resistance | > 297.00 | [Ohm] | battery voltage | not calibrated | [V] | 5 [events] once / DCY | 2 DCY |
|
||||
| or | |||||||||||||||
| battery voltage | < 10.70 | [V] | |||||||||||||
| for time | < 1.5 | [s] | |||||||||||||
| or | |||||||||||||||
| battery voltage | > 9.80 | [V] | |||||||||||||
| battery voltage | <= 16.10 | [V] | |||||||||||||
| conditions above must be fulfilled | |||||||||||||||
| for time | >= 0.1 | [s] | |||||||||||||
| normal ASIC operation in SWITCHON mode | |||||||||||||||
| for number of events | >= 10 | [events] | |||||||||||||
| Oxygen Sensor (O2S) front | P2629 - O2 Sensor Pumping Current Trim Circuit/Open Bank 2 Sensor 1 | open circuit | calculated calibration resistance | > 297.00 | [Ohm] | battery voltage | not calibrated | [V] | 5 [events] once / DCY | 2 DCY |
|
||||
| or | |||||||||||||||
| battery voltage | < 10.70 | [V] | |||||||||||||
| for time | < 1.5 | [s] | |||||||||||||
| or | |||||||||||||||
| battery voltage | > 9.80 | [V] | |||||||||||||
| battery voltage | <= 16.10 | [V] | |||||||||||||
| conditions above must be fulfilled | |||||||||||||||
| for time | >= 0.1 | [s] | |||||||||||||
| normal ASIC operation in SWITCHON mode | |||||||||||||||
| for number of events | >= 10 | [events] | |||||||||||||
| Oxygen Sensor (O2S) front | P223C - O2 Sensor Pumping Current Range/Performance Bank 1 | range check (detection of blackening protection) | voltage for fixed pump current duty cycle | > 2.00 | [V] | general conditions | 10 [events] continuous | 2 DCY |
|
||||||
| or | battery voltage | 10.70...16.10 | [V] | ||||||||||||
| voltage for fixed pump current duty cycle | <= -1.40 | [V] | or | ||||||||||||
| each criterion above must be fulfilled for minimum number of checks (out of 16 successive checks) | additional debouncing @ sufficient battery voltage | ||||||||||||||
| number of checks | >= 6.00 | [-] | battery voltage | not calibrated | [V] | ||||||||||
| local pre-debounce | > 2.6 | [s] | time delay | < 1.5 | [s] | ||||||||||
| additional debouncing @ lowbattery voltage | |||||||||||||||
| battery voltage | > 9.80 | [V] | |||||||||||||
| time delay | >= 0.1 | [s] | |||||||||||||
| O2S front conditions | |||||||||||||||
| pump current operation | active | ||||||||||||||
| counter for verification of theactual mode | > 10.00 | [-] | |||||||||||||
| diagnosis intervention | not requested | ||||||||||||||
| pump current package | valid | ||||||||||||||
| O2S front ceramictemperature | > 634.0 | [°C] | |||||||||||||
| or | |||||||||||||||
| O2S front heating | finished | ||||||||||||||
| O2S front heater controldeviation | < 65.0 | [K] | |||||||||||||
| for time | >= $ UEGO_tiDlySnsrTstdOkRels_C} | [s] | |||||||||||||
| range check (positive or negative voltage drop @ internal resistor) | negative voltage drop deviation duringpump current pulse | > 0.25 | [V] | general conditions | 10 [events] continuous | 2 DCY | |||||||||
| for time | >= 0.1 | [s] | battery voltage | 10.70...16.10 | [V] | ||||||||||
| within number of negative overshoots | > 0.00 | [-] | or | ||||||||||||
| or | additional debouncing @ sufficient battery voltage | ||||||||||||||
| positive voltage drop deviation during pump current pulse | > 0.31 | [V] | battery voltage | < 10.70 | [V] | ||||||||||
| for time | >= 0.1 | [s] | time delay | < 1.5 | [s] | ||||||||||
| within number of positive overshoots | > 0.00 | [-] | additional debouncing @ low battery voltage | ||||||||||||
| battery voltage | > 9.80 | [V] | |||||||||||||
| time delay | >= 0.1 | [s] | |||||||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| O2S front conditions | |||||||||||||||
| pump current operation | active | ||||||||||||||
| counter for verification of theactual mode | > 10.00 | [-] | |||||||||||||
| diagnosis intervention | not requested | ||||||||||||||
| pump current package | valid | ||||||||||||||
| O2S front ceramictemperature | > 634.0 | [°C] | |||||||||||||
| or | |||||||||||||||
| O2S front heating | finished | ||||||||||||||
| O2S front heater controldeviation | < 65.0 | [K] | |||||||||||||
| for time | >= 0.1 | [s] | |||||||||||||
| Oxygen Sensor (O2S) front | P223D - O2 Sensor Pumping Current Range/Performance Bank 2 | range check (detection of blackening protection) | voltage for fixed pump current duty cycle | > 2.00 | [V] | general conditions | 10 [events] continuous | 2 DCY |
|
||||||
| or | battery voltage | 10.70...16.10 | [V] | ||||||||||||
| voltage for fixed pump current duty cycle | <= -1.40 | [V] | or | ||||||||||||
| each criterion above must be fulfilled for minimum number of checks (out of 16 successive checks) | additional debouncing @ sufficient battery voltage | ||||||||||||||
| number of checks | >= 6.00 | [-] | battery voltage | < 10.70 | [V] | ||||||||||
| local pre-debounce | > 2.6 | [s] | time delay | < 1.5 | [s] | ||||||||||
| additional debouncing @ lowbattery voltage | |||||||||||||||
| battery voltage | > 9.80 | [V] | |||||||||||||
| time delay | >= 0.1 | [s] | |||||||||||||
| or | |||||||||||||||
| O2S front conditions | |||||||||||||||
| pump current operation | active | ||||||||||||||
| counter for verification of theactual mode | > 10.00 | [-] | |||||||||||||
| diagnosis intervention | not requested | ||||||||||||||
| pump current package | valid | ||||||||||||||
| O2S front ceramictemperature | > 634.0 | [°C] | |||||||||||||
| O2S front heating | finished | ||||||||||||||
| O2S front heater controldeviation | < 65.0 | [K] | |||||||||||||
| for time | >= 0.1 | [s] | |||||||||||||
| range check (positive or negative voltage drop @ internal resistor) | negative voltage drop deviation duringpump current pulse | > 0.25 | [V] | general conditions | 10 [events] continuous | 2 DCY | |||||||||
| for time | >= 0.1 | [s] | battery voltage | 10.70...16.10 | [V] | ||||||||||
| within number of negative overshoots | > 0.00 | [-] | or | ||||||||||||
| or | additional debouncing @ sufficient battery voltage | ||||||||||||||
| positive voltage drop deviation during pumpcurrent pulse | > 0.31 | [V] | battery voltage | < 10.70 | [V] | ||||||||||
| for time | >= 0.1 | [s] | time delay | < 1.5 | [s] | ||||||||||
| within number of positive overshoots | > 0.00 | [-] | additional debouncing @ lowbattery voltage | ||||||||||||
| battery voltage | > 9.80 | [V] | |||||||||||||
| time delay | >= 0.1 | [s] | |||||||||||||
| O2S front conditions | |||||||||||||||
| pump current operation | active | ||||||||||||||
| counter for verification of theactual mode | > 10.00 | [-] | |||||||||||||
| diagnosis intervention | not requested | ||||||||||||||
| pump current package | valid | ||||||||||||||
| O2S front ceramictemperature | > 634.0 | [°C] | |||||||||||||
| or | |||||||||||||||
| O2S front heating | finished | ||||||||||||||
| O2S front heater controldeviation | < 65.0 | [K] | |||||||||||||
| for time | >= 0.1 | [s] | |||||||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Oxygen Sensor (O2S) front | P0131 - O2 Sensor Circuit Low Voltage Bank 1 Sensor 1 | circuit low (aborted RAM check) under voltage check @ sensor lines | voltage @ sensor pump current, virtual ground, trim current or nernst current | < -0.15 | [V] | battery voltage | >= 10.70 | [V] | 5 [events] continuous | 2 DCY |
|
|||
| or | ||||||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||||
| for time | < 1.5 | [s] | ||||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||||
| conditions above must be fulfilled | ||||||||||||||
| for time | >= 0.1 | [s] | ||||||||||||
| circuit low (idle mode) under voltage check @ sensor lines | voltage @ sensor pump current, virtual ground, trim current or nernst current | < -0.15 | [V] | battery voltage | >= 10.70 | [V] | 5 [events] multiple | 2 DCY | ||||||
| or | ||||||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||||
| for time | < 1.5 | [s] | ||||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||||
| conditions above must be fulfilled | ||||||||||||||
| for time | >= 0.1 | [s] | ||||||||||||
| circuit low (switch-on or warm- up mode) voltage check @ sensor lines | voltage drop | > -0.20 | [V] | battery voltage | >= 10.70 | [V] | 5 [events] multiple | 2 DCY | ||||||
| or | ||||||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||||
| for time | < 10700.0 | [s] | ||||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||||
| conditions above must be fulfilled | ||||||||||||||
| for time | >= 0.1 | [s] | ||||||||||||
| Oxygen Sensor (O2S) front | P0151 - O2 Sensor Circuit Low Voltage Bank 2 Sensor 1 | circuit low (aborted RAM check) undervoltage check @ sensor lines | voltage @ sensor pump current, virtual ground, trim current or nernst current | < -0.15 | [V] | battery voltage | not calibrated | [V] | 5 [events] continuous | 2 DCY |
|
|||
| or | ||||||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||||
| for time | < 1.5 | [s] | ||||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||||
| conditions above must be fulfilled | ||||||||||||||
| for time | >= 0.1 | [s] | ||||||||||||
| circuit low (idle mode) undervoltage check @ sensor lines | voltage @ sensor pump current, virtual ground, trim current or nernst current | < -0.15 | [V] | battery voltage | not calibrated | [V] | 5 [events] multiple | 2 DCY | ||||||
| or | ||||||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||||
| for time | < 1.5 | [s] | ||||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||||
| conditions above must be fulfilled | ||||||||||||||
| for time | >= 0.1 | [s] | ||||||||||||
| circuit low (switch-on or warm- up mode) voltage check @ sensor lines | voltage drop | < -0.2 | [V] | battery voltage | not calibrated | [V] | 5 [events] multiple | 2 DCY | ||||||
| or | ||||||||||||||
| battery voltage | < 10.70 | [V] | ||||||||||||
| for time | < 1.5 | [s] | ||||||||||||
| battery voltage | > 9.80 | [V] | ||||||||||||
| battery voltage | <= 16.10 | [V] | ||||||||||||
| conditions above must be fulfilled | ||||||||||||||
| for time | >= 0.1 | [s] | ||||||||||||
| Oxygen Sensor (O2S) front | P0040 - O2 Sensor Signals Swapped Bank 1 Sensor 1 / Bank 2 Sensor 1 | signal range check (detection of exchange lambda sensors upstream catalyst) | lambda controllers exceed thresholds in opposite directions | lambda control | closed loop | 5.0 [s] multiple | 2 DCY |
|
||||||
| case 1: | VVT | ready | ||||||||||||
| lambda control value bank 1 | < 0.80 | [-] | ||||||||||||
| lambda control value bank 2 | > 1.20 | [-] | ||||||||||||
| or | ||||||||||||||
| case 2: | ||||||||||||||
| lambda control value bank 1 | > 1.20 | [-] | ||||||||||||
| lambda control value bank 2 | < 0.80 | [-] | ||||||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Oxygen Sensor (O2S) front | P2195 - O2 Sensor Signal Biased/Stuck Lean Bank 1 Sensor 1 | out of range high | adapted I-part of 2nd lambda control loop (O2S front offset) | > 0.07 | [-] | condition for lambda split operation | [s] | 450 [s] multiple | 2 DCY |
|
|
| catalyst heating | not calibrated | ||||||||||
| pending fault from previous DCY O2S front offset monitor | |||||||||||
| O2S rear control loop (i-part) (Referenced) | checked | ||||||||||
| for time | >= 65.0 | ||||||||||
| only final conditions: fault debounce of: | |||||||||||
| O2S Front Offset Adaptation (Referenced) | fulfilled | ||||||||||
| additional conditions | |||||||||||
| soot mass conditions(Referenced) | not calibrated | ||||||||||
| Oxygen Sensor (O2S) front | P2196 - O2 Sensor Signal Biased/Stuck Rich Bank 1 Sensor 1 | out of range low | adapted I-part of 2nd lambda control loop (O2S front offset) | < -0.07 | [-] | condition for lambda split operation | [s] | 450 [s] multiple | 2 DCY |
|
|
| catalyst heating | not calibrated | ||||||||||
| pending fault from previous DCY O2S front offset monitor | |||||||||||
| O2S rear control loop (i-part) (Referenced) | checked | ||||||||||
| for time | >= 65.0 | ||||||||||
| only final conditions: fault debounce of: | |||||||||||
| O2S Front Offset Adaptation (Referenced) | fulfilled | ||||||||||
| additional conditions: | |||||||||||
| soot mass conditions(Referenced) | not calibrated | ||||||||||
| Oxygen Sensor (O2S) front | P2197 - O2 Sensor Signal Biased/Stuck Lean Bank 2 Sensor 1 | out of range high | adapted I-part of 2nd lambda control loop (O2S front offset) | > 0.07 | [-] | condition for lambda split operation | [s] | 450 [s] multiple | 2 DCY |
|
|
| catalyst heating | not calibrated | ||||||||||
| pending fault from previous DCY O2S front offset monitor | |||||||||||
| O2S rear control loop (i-part) (Referenced) | checked | ||||||||||
| for time | >= 65.0 | ||||||||||
| only final conditions: fault debounce of: | |||||||||||
| O2S Front Offset Adaptation (Referenced) | fulfilled | ||||||||||
| additional conditions | |||||||||||
| soot mass conditions(Referenced) | not calibrated | ||||||||||
| Oxygen Sensor (O2S) front | P2198 - O2 Sensor Signal Biased/Stuck Rich Bank 2 Sensor 1 | out of range low | adapted I-part of 2nd lambda control loop (O2S front offset) | < -0.07 | [-] | condition for lambda split operation | [s] | 450 [s]multiple | 2 DCY |
|
|
| catalyst heating | not calibrated | ||||||||||
| pending fault from previous DCY O2S front offset monitor | |||||||||||
| O2S rear control loop (i-part) (Referenced) | checked | ||||||||||
| for time | >= 65.0 | ||||||||||
| only final conditions: fault debounce of: | |||||||||||
| O2S Front Offset Adaptation (Referenced) | fulfilled | ||||||||||
| additional conditions: | |||||||||||
| soot mass conditions(Referenced) | not calibrated | ||||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Oxygen Sensor (O2S) front | P2414 - O2 Sensor Exhaust Sample Error Bank 1 Sensor 1 | signal range check (check for sensor at ambient air) | O2S signal front | > 5.00 | [-] | engine | running | 10.0 [s] multiple | 2 DCY |
|
|||||
| for time | > 10.0 | [s] | O2S front | ready | |||||||||||
| fuel cut off | not active | ||||||||||||||
| PCV leakage | not detected | ||||||||||||||
| lambda set value | < 1.60 | [-] | |||||||||||||
| O2S front ceramic temperature | valid | ||||||||||||||
| dev. actual vs. setpoint O2Sceramic temperature | < 65.0 | [°C] | |||||||||||||
| if AIR system equipped | |||||||||||||||
| AIR | not active | ||||||||||||||
| Oxygen Sensor (O2S) front | P2415 - O2 Sensor Exhaust Sample Error Bank 2 Sensor 1 | signal range check (check for sensor at ambient air) | O2S signal front | > 5.00 | [-] | engine | running | 10.0 [s] multiple | 2 DCY |
|
|||||
| for time | > 10.0 | [s] | O2S front | ready | |||||||||||
| fuel cut off | not active | ||||||||||||||
| PCV leakage | not detected | ||||||||||||||
| lambda set value | < 1.60 | [-] | |||||||||||||
| O2S front ceramic temperature | valid | ||||||||||||||
| dev. actual vs. setpoint O2Sceramic temperature | < 65.0 | [°C] | |||||||||||||
| if AIR system equipped | |||||||||||||||
| AIR | not active | ||||||||||||||
| Oxygen Sensor (O2S) Heater front | P0135 - O2 Sensor Heater Circuit Bank 1 Sensor 1 | out of range (low temperature) | O2S ceramic temperature | < 654.0 | [°C] | general conditions | 2.0 [s] continuous | 2 DCY |
|
||||||
| battery voltage | not calibrated | [V] | |||||||||||||
| or | |||||||||||||||
| battery voltage | < 10.70 | [V] | |||||||||||||
| for time | < 1.5 | [s] | |||||||||||||
| battery voltage | > 9.80} | [V] | |||||||||||||
| battery voltage | <= 16.10 | [V] | |||||||||||||
| conditions above must be fulfilled | |||||||||||||||
| for time | >= 0.1 | [s] | |||||||||||||
| engine conditions | |||||||||||||||
| ECM pre-drive | detected | ||||||||||||||
| modeled EGT | >= 200.0 | [°C] | |||||||||||||
| fuel cut off | not active | ||||||||||||||
| for time | >= 30.0 | [s] | |||||||||||||
| out of range (permanent) | O2S ceramic temperature | < 680.0 | [°C] | general conditions | 55.0 [s] continuous | 2 DCY | |||||||||
| battery voltage | not calibrated | [V] | |||||||||||||
| or | |||||||||||||||
| battery voltage | < 10.70 | [V] | |||||||||||||
| for time | < 1.5 | [s] | |||||||||||||
| battery voltage | > 9.80 | [V] | |||||||||||||
| battery voltage | <= 16.10 | [V] | |||||||||||||
| conditions above must be fulfilled | |||||||||||||||
| for time | >= 0.1 | [s] | |||||||||||||
| effective O2S heater voltage | >= 10.80 | [V] | |||||||||||||
| engine conditions | |||||||||||||||
| ECM pre-drive | not detected | ||||||||||||||
| modeled EGT | >= 300.0 | [°C] | |||||||||||||
| fuel cut off | not active | ||||||||||||||
| for time | >= 40.0 | [s] | |||||||||||||
| rationality check (sensor heating up after engine start) | O2S ceramic temperature | < 680.0 | [°C] | general conditions | 0 [s] once / DCY | 2 DCY | |||||||||
| battery voltage | not calibrated | [V] | |||||||||||||
| or | |||||||||||||||
| battery voltage | < 10.70 | [V] | |||||||||||||
| for time | < 1.5 | [s] | |||||||||||||
| battery voltage | > 9.80 | [V] | |||||||||||||
| battery voltage | <= 16.10 | [V] | |||||||||||||
| conditions above must be fulfilled | |||||||||||||||
| for time | >= 0.1 | [s] | |||||||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| all conditions below must be accumulated fulfilled | |||||||||||||||
| for time | >= 40.0 | [s] | |||||||||||||
| ECT @ start | >= -48.0 | [°C] | |||||||||||||
| for ECM pre-drive | detected | ||||||||||||||
| or | |||||||||||||||
| ECT | >= -48.0 | [°C] | |||||||||||||
| for ECM pre-drive | not detected | ||||||||||||||
| conditions (improved robustness) | |||||||||||||||
| for accumulated time | <= 10.0 | [s] | |||||||||||||
| Oxygen Sensor (O2S) Heater front | P0155 - O2 Sensor Heater Circuit Bank 2 Sensor 1 | out of range (low temperature) | O2S ceramic temperature | < 654.0 | [°C] | general conditions | 2.0 [s] continuous | 2 DCY |
|
||||||
| battery voltage | [V] | ||||||||||||||
| or | |||||||||||||||
| battery voltage | < 10.70 | [V] | |||||||||||||
| for time | < 1.5 | [s] | |||||||||||||
| battery voltage | > 10.70 | [V] | |||||||||||||
| battery voltage | <= 16.10 | [V] | |||||||||||||
| conditions above must be fulfilled | |||||||||||||||
| for time | > 0.1 | [s] | |||||||||||||
| engine conditions | |||||||||||||||
| ECM pre-drive | detected | ||||||||||||||
| modeled EGT | >= 200.0 | [°C] | |||||||||||||
| fuel cut off | not active | ||||||||||||||
| for time | >= 30.0 | [s] | |||||||||||||
| out of range (permanent) | O2S ceramic temperature | < 680.0 | [°C] | general conditions | 55.0 [s] continuous | 2 DCY | |||||||||
| battery voltage | not calibrated | [V] | |||||||||||||
| or | |||||||||||||||
| battery voltage | < 10.70 | [V] | |||||||||||||
| for time | < 1.5 | [s] | |||||||||||||
| battery voltage | > 10.70 | [V] | |||||||||||||
| battery voltage | <= 16.10 | [V] | |||||||||||||
| conditions above must be fulfilled | |||||||||||||||
| for time | >= 0.1 | [s] | |||||||||||||
| effective O2S heater voltage | >= 10.80 | [V] | |||||||||||||
| engine conditions | |||||||||||||||
| ECM drive mode | not detected | ||||||||||||||
| modeled EGT | >= 300.0 | [°C] | |||||||||||||
| fuel cut off | not active | ||||||||||||||
| for time | >= 40.0 | [s] | |||||||||||||
| rationality check (sensor heating up after engine start) | O2S ceramic temperature | < 680.0 | [°C] | general conditions | 0 [s] once / DCY | 2 DCY | |||||||||
| battery voltage | not calibrated | [V] | |||||||||||||
| or | |||||||||||||||
| battery voltage | < 10.70 | [V] | |||||||||||||
| for time | < 1.5 | [s] | |||||||||||||
| battery voltage | > 10.70 | [V] | |||||||||||||
| battery voltage | <= 16.10 | [V] | |||||||||||||
| conditions above must be fulfilled | |||||||||||||||
| for time | >= 0.1 | [s] | |||||||||||||
| all conditions below must be accumulated fulfilled | |||||||||||||||
| for time | >= 40.0 | [s] | |||||||||||||
| ECT @ start | >= -48.0 | [°C] | |||||||||||||
| for ECM pre-drive | detected | ||||||||||||||
| or | |||||||||||||||
| ECT | >= -48.0 | [°C] | |||||||||||||
| for ECM pre-drive | not detected | ||||||||||||||
| conditions (improved robustness) | |||||||||||||||
| for accumulated time | <= 10.0 | [s] | |||||||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Oxygen Sensor (O2S) Heater front | P0030 - HO2S Heater Control Circuit Bank 1 Sensor 1 | open circuit | signal voltage | > 2.74...3.26 | [V] | duty cycle | <= 97.00 | [%] | 0.5 [s] continuous | 2 DCY |
|
| signal voltage | <= 4.70...5.40 | [V] | battery voltage | >= 10.70 | [V] | ||||||
| or | |||||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80 | [V] | |||||||||
| battery voltage | <= 16.10 | [V] | |||||||||
| conditions above must be fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| Oxygen Sensor (O2S) Heater front | P0031 - HO2S Heater Control Circuit Low Bank 1 Sensor 1 | circuit low | signal voltage | <= 2.74...3.26 | [V] | duty cycle | <= 97.00 | [%] | 0.5 [s] continuous | 2 DCY |
|
| battery voltage | >= 10.70 | [V] | |||||||||
| or | |||||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80 | [V] | |||||||||
| battery voltage | <= 16.10 | [V] | |||||||||
| conditions above must be fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| Oxygen Sensor (O2S) Heater front | P0032 - HO2S Heater Control Circuit High Bank 1 Sensor 1 | circuit high | signal current | >= 8.50...12.50 | [A] | duty cycle | >= 4.00 | [%] | 0.5 [s] continuous | 2 DCY |
|
| battery voltage | >= 10.70 | [V] | |||||||||
| or | |||||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80 | [V] | |||||||||
| battery voltage | <= 16.10 | [V] | |||||||||
| conditions above must be fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| Oxygen Sensor (O2S) Heater front | P0050 - HO2S Heater Control Circuit Bank 2 Sensor 1 | open circuit | signal voltage | > 2.74...3.26 | [V] | duty cycle | <= 97.00 | [%] | 0.5 [s] continuous | 2 DCY |
|
| signal voltage | <= 4.70...5.40 | [V] | battery voltage | not calibrated | [V] | ||||||
| or | |||||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80 | [V] | |||||||||
| battery voltage | <= 16.10 | [V] | |||||||||
| conditions above must be fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| Oxygen Sensor (O2S) Heater front | P0051 - HO2S Heater Control Circuit Low Bank 2 Sensor 1 | circuit low | signal voltage | <= 2.74...3.26 | [V] | duty cycle | <= 97.00 | [%] | 0.5 [s] continuous | 2 DCY |
|
| battery voltage | not calibrated | [V] | |||||||||
| or | |||||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80 | [V] | |||||||||
| battery voltage | <= 16.10 | [V] | |||||||||
| conditions above must be fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| Oxygen Sensor (O2S) Heater front | P0052 - HO2S Heater Control Circuit High Bank 2 Sensor 1 | circuit high | signal current | >= 8.50...12.50 | [A] | duty cycle | >= 4.00 | [%] | 0.5 [s] continuous | 2 DCY |
|
| battery voltage | not calibrated | [V] | |||||||||
| or | |||||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80 | [V] | |||||||||
| battery voltage | <= 16.10 | [V] | |||||||||
| conditions above must be fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Oxygen Sensor (O2S) rear | P013A - O2 Sensor Slow Response - Rich to Lean Bank 1 Sensor 2 | intrusive monitor check of transient time at rich to lean transition | arithmetic average value | active diagnosis | 10.0 [s] once / DCY | 1 DCY |
|
||||
| time at rich to lean transition | not calibrated | [s] | enable conditions for active lambda stimulation (Referenced) | checked | |||||||
| or | passive diagnosis | ||||||||||
| EWMA filter value transient | passive lambda diagnosis(fuel cut off) (Referenced) | not calibrated | |||||||||
| time at rich to lean transition | > 0.6 | [s] | for arithmetic average value calculation | ||||||||
| number of checks required forvalid result | not calibrated | [-] | |||||||||
| for EWMA-filter | |||||||||||
| K-factor | 0.38 | [-] | |||||||||
| minimum number of tests perDCY required | 1 | [-] | |||||||||
| step change detection will initiate multiple tests per DCY conditions for step change detection | |||||||||||
| deviation new measuredvalue vs. old EWMA filtered value | > 0.3 | [s] | |||||||||
| number of checks for confirmation | 2.00 | [-] | |||||||||
| maximum tolerance to confirm filtered value | 0.0 | [s] | |||||||||
| initial value of filtered value | 0.0 | [s] | |||||||||
| maximum number of checks per DCY | 2.00 | [-] | |||||||||
| additional conditions | |||||||||||
| soot mass conditions(Referenced) | not calibrated | ||||||||||
| Oxygen Sensor (O2S) rear | P013B - O2 Sensor Slow Response - Lean to Rich Bank 1 Sensor 2 | intrusive monitor check of transient time at lean to rich transition | arithmetic average value | monitor entry conditions | 10.0 [s] once / DCY | 1 DCY |
|
||||
| time at lean to rich transition | not calibrated | [s] | enable conditions for active lambda stimulation (Referenced) | checked | |||||||
| or | for arithmetic average value calculation | ||||||||||
| EWMA filter value transient | number of checks required forvalid result | not calibrated | [-] | ||||||||
| time at lean to rich transition | > 0.6 | [s] | or | ||||||||
| for EWMA-filter | |||||||||||
| K-factor | 0.35 | [-] | |||||||||
| minimum number of tests perDCY required | 1 | ||||||||||
| step change detection will initiate multiple tests per DCY conditions for step change detection | |||||||||||
| deviation between new measured value and old EWMA filtered value | > 0.3 | [s] | |||||||||
| number of checks for confirmation | 3.00 | [-] | |||||||||
| maximum tolerance to confirm filtered value | 0.1 | [s] | |||||||||
| initial value of filtered value | 0.0 | [s] | |||||||||
| maximum number of checks per driving cycle | 3.00 | [-] | |||||||||
| additional conditions | |||||||||||
| soot mass conditions(Referenced) | not calibrated | ||||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Oxygen Sensor (O2S) rear | P013C - O2 Sensor Slow Response - Rich to Lean Bank 2 Sensor 2 | intrusive monitor check of transient time at rich to lean transition | arithmetic average value | active diagnosis | 10.0 [s] once / DCY | 1 DCY |
|
||||
| time at rich to lean transition | not calibrated | [s] | enable conditions for active lambda stimulation (Referenced) | checked | |||||||
| or | passive diagnosis | ||||||||||
| EWMA filter value transient | passive lambda diagnosis(fuel cut off) (Referenced) | not calibrated | |||||||||
| time at rich to lean transition | > 0.6 | [s] | for arithmetic average value calculation | ||||||||
| number of checks required forvalid result | not calibrated | [-] | |||||||||
| for EWMA-filter | |||||||||||
| K-factor | 0.38 | [-] | |||||||||
| minimum number of tests perDCY required | 1 | [-] | |||||||||
| step change detection will initiate multiple tests per DCY conditions for step change detection | |||||||||||
| deviation new measuredvalue vs. old EWMA filtered value | > 0.3 | [s] | |||||||||
| number of checks for confirmation | 2.00 | [-] | |||||||||
| maximum tolerance to confirm filtered value | 0.0 | [s] | |||||||||
| initial value of filtered value | 0.0 | [s] | |||||||||
| maximum number of checks per DCY | 2.00 | [-] | |||||||||
| additional conditions | |||||||||||
| soot mass conditions(Referenced) | not calibrated | ||||||||||
| Oxygen Sensor (O2S) rear | P013D - O2 Sensor Slow Response - Lean to Rich Bank 2 Sensor 2 | intrusive monitor check of transient time at lean to rich transition | arithmetic average value | monitor entry conditions | 10.0 [s] once / DCY | 1 DCY |
|
||||
| time at lean to rich transition | not calibrated | [s] | enable conditions for active lambda stimulation (Referenced) | checked | |||||||
| or | for arithmetic average value calculation | ||||||||||
| EWMA filter value transient | number of checks required forvalid result | not calibrated | [-] | ||||||||
| time at lean to rich transition | > 0.6 | [s] | or | ||||||||
| for EWMA-filter | |||||||||||
| K-factor | 0.35 | [-] | |||||||||
| minimum number of tests perDCY required | 1 | ||||||||||
| step change detection will initiate multiple tests per DCY conditions for step change detection | |||||||||||
| deviation between new measured value and old EWMA filtered value | > 0.3 | [s] | |||||||||
| number of checks for confirmation | 3.00 | [-] | |||||||||
| maximum tolerance to confirm filtered value | 0.1 | [s] | |||||||||
| initial value of filtered value | 0.0 | [s] | |||||||||
| maximum number of checks per driving cycle | 3.00 | [-] | |||||||||
| additional conditions | |||||||||||
| soot mass conditions(Referenced) | not calibrated | ||||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Oxygen Sensor (O2S) rear | P013E - O2 Sensor Delayed Response - Rich to Lean Bank 1 Sensor 2 | intrusive monitor delayed response monitoring, delay measurement | arithmetic average value | monitor entry conditions | 20.0 [s] once / DCY | 1 DCY |
|
||||
| delay time at rich to lean transition | not calibrated | [s] | enable conditions for active lambda stimulation (Referenced) | checked | |||||||
| or | for arithmetic average value calculation | ||||||||||
| EWMA filter value transient | number of checks required forvalid result | not calibrated | [-] | ||||||||
| delay time at rich to lean transition | > 0.3 | [s] | for EWMA-filter | ||||||||
| K-factor | 0.38 | [-] | |||||||||
| minimum number of tests perDCY required | 1 | ||||||||||
| step change detection will initiate multiple tests per DCY conditions for step change detection | |||||||||||
| dev. new measured value vs.old EWMA filtered value | > 0.3 | [s] | |||||||||
| number of checks for confirmation | 4 | [-] | |||||||||
| maximum tolerance to confirm filtered value | 0.0 | [s] | |||||||||
| initial value of filtered value | 0.0 | [s] | |||||||||
| maximum number of checks per driving cycle | 2 | [-] | |||||||||
| additional conditions | |||||||||||
| soot mass conditions(Referenced) | not calibrated | ||||||||||
| Oxygen Sensor (O2S) rear | P013F - O2 Sensor Delayed Response - Lean to Rich Bank 1 Sensor 2 | intrusive monitor delayed response monitoring, delay measurement | arithmetic average value | monitor entry conditions | 20.0 [s] once / DCY | 1 DCY |
|
||||
| delay time at lean to rich transition | not calibrated | [s] | enable conditions for active lambda stimulation (Referenced) | checked | |||||||
| or | for arithmetic average value calculation | ||||||||||
| EWMA filter value transient | number of checks required forvalid result | not calibrated | [-] | ||||||||
| delay time at lean to rich transition | > 0.6 | [s] | for EWMA-filter | ||||||||
| K-factor | 0.35 | [-] | |||||||||
| minimum number of tests perDCY required | 1 | ||||||||||
| step change detection will initiate multiple tests per DCY conditions for step change detection | |||||||||||
| dev. new measured value vs.old EWMA filtered value | > 0.3 | [s] | |||||||||
| number of checks for confirmation | 5 | [-] | |||||||||
| maximum tolerance to confirm filtered value | <= 0.1 | [s] | |||||||||
| initial value of filtered value | 0.0 | [s] | |||||||||
| maximum number of checks per driving cycle | 3 | [-] | |||||||||
| additional conditions | |||||||||||
| soot mass conditions(Referenced) | not calibrated | ||||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Oxygen Sensor (O2S) rear | P014A - O2 Sensor Delayed Response - Rich to Lean Bank 2 Sensor 2 | intrusive monitor delayed response monitoring, delay measurement | arithmetic average value | monitor entry conditions | 20.0 [s] once / DCY | 1 DCY |
|
||||
| delay time at rich to lean transition | not calibrated | [s] | enable conditions for active lambda stimulation (Referenced) | checked | |||||||
| or | for arithmetic average value calculation | ||||||||||
| EWMA filter value transient | number of checks required forvalid result | not calibrated | [-] | ||||||||
| delay time at rich to lean transition | > 0.3 | [s] | for EWMA-filter | ||||||||
| K-factor | 0.38 | [-] | |||||||||
| minimum number of tests perDCY required | 1 | ||||||||||
| step change detection will initiate multiple tests per DCY conditions for step change detection | |||||||||||
| dev. new measured value vs.old EWMA filtered value | > 0.3 | [s] | |||||||||
| number of checks for confirmation | 4 | [-] | |||||||||
| maximum tolerance to confirm filtered value | 0.0 | [s] | |||||||||
| initial value of filtered value | 0.0 | [s] | |||||||||
| maximum number of checks per driving cycle | 2 | [-] | |||||||||
| additional conditions | |||||||||||
| soot mass conditions(Referenced) | not calibrated | ||||||||||
| Oxygen Sensor (O2S) rear | P014B - O2 Sensor Delayed Response - Lean to Rich Bank 2 Sensor 2 | intrusive monitor delayed response monitoring, delay measurement | arithmetic average value | monitor entry conditions | 20.0 [s] once / DCY | 1 DCY |
|
||||
| delay time at lean to rich transition | not calibrated | [s] | enable conditions for active lambda stimulation (Referenced) | checked | |||||||
| or | for arithmetic average value calculation | ||||||||||
| EWMA filter value transient | number of checks required forvalid result | not calibrated | [-] | ||||||||
| delay time at lean to rich transition | > 0.6 | [s] | for EWMA-filter | ||||||||
| K-factor | 0.35 | [-] | |||||||||
| minimum number of tests perDCY required | 1 | ||||||||||
| step change detection will initiate multiple tests per DCY conditions for step change detection | |||||||||||
| dev. new measured value vs.old EWMA filtered value | > 0.3 | [s] | |||||||||
| number of checks for confirmation | 5 | [-] | |||||||||
| maximum tolerance to confirm filtered value | <= 0.1 | [s] | |||||||||
| initial value of filtered value | 0.0 | [s] | |||||||||
| maximum number of checks per driving cycle | 3 | [-] | |||||||||
| additional conditions | |||||||||||
| soot mass conditions(Referenced) | not calibrated | ||||||||||
| Oxygen Sensor (O2S) rear | P2270 - O2 Sensor Signal Biased/Stuck Lean Bank 1 Sensor 2 | intrusive monitor O2S signal check - stuck low | general | general conditions | 20.00 [s] once / DCY | 2 DCY |
|
||||
| O2S sensor voltage | < 0.75 | [V] | enable conditions for active lambda stimulation (Referenced) | checked | |||||||
| step 1 | step 1 | ||||||||||
| cumulated rich gas mass flow intocatalyst | >= 1400 | [mg] | requested lambda | 0.92...0.92 | [-] | ||||||
| step 2 | step 2 | ||||||||||
| integrated exhaust gas mass flow | >= 75.0 | [g] | requested lambda | 0.75 | [-] | ||||||
| for time | >= 2.0 | [s] | additional conditions: | ||||||||
| soot mass conditions(Referenced) | not calibrated | ||||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Oxygen Sensor (O2S) rear | P2271 - O2 Sensor Signal Biased/Stuck Rich Bank 1 Sensor 2 | intrusive monitor O2S signal check - stuck high | general | active diagnosis | 20 [s] once / DCY | 2 DCY |
|
||||
| O2S sensor voltage | > 0.15 | [V] | general conditions | ||||||||
| active diagnosis | enable conditions for active lambda stimulation (Referenced) | checked | |||||||||
| step 1 | step 1 | ||||||||||
| cumulated O2 mass flow intocatalyst | >= 1100 | [mg] | requested lambda | 1.08 | [-] | ||||||
| step 2 | step 2 | ||||||||||
| integrated exhaust gas mass flow | >= 75.0 | [g] | requested lambda | 1.15 | [-] | ||||||
| for time | >= 2.0 | [s] | or | ||||||||
| or | passive diagnosis | ||||||||||
| passive diagnosis | passive lambda diagnosis(fuel cut off) (Referenced) | not calibrated | |||||||||
| cumulated O2 mass flow into catalyst | not calibrated | [mg] | additional conditions: | ||||||||
| soot mass conditions (Referenced) | not calibrated | ||||||||||
| Oxygen Sensor (O2S) rear | P2272 - O2 Sensor Signal Biased/Stuck Lean Bank 2 Sensor 2 | intrusive monitor O2S signal check - stuck low | general | general conditions | 20.00 [s] once / DCY | 2 DCY |
|
||||
| O2S sensor voltage | < 0.75 | [V] | enable conditions for active lambda stimulation (Referenced) | checked | |||||||
| step 1 | step 1 | ||||||||||
| cumulated rich gas mass flow intocatalyst | >= 1400 | [mg] | requested lambda | 0.92...0.92 | [-] | ||||||
| step 2 | step 2 | ||||||||||
| integrated exhaust gas mass flow | >= 75.0 | [g] | requested lambda | 0.75 | [-] | ||||||
| for time | >= 2.0 | [s] | additional conditions: | ||||||||
| soot mass conditions(Referenced) | not calibrated | ||||||||||
| Oxygen Sensor (O2S) rear | P2273 - O2 Sensor Signal Biased/Stuck Rich Bank 2 Sensor 2 | intrusive monitor O2S signal check - stuck high | general | active diagnosis | 20 [s] once / DCY | 2 DCY |
|
||||
| O2S sensor voltage | > 0.15 | [V] | general conditions | ||||||||
| active diagnosis | enable conditions for active lambda stimulation (Referenced) | checked | |||||||||
| step 1 | step 1 | ||||||||||
| cumulated O2 mass flow intocatalyst | >= 1100 | [mg] | requested lambda | 1.08 | [-] | ||||||
| step 2 | step 2 | ||||||||||
| integrated exhaust gas mass flow | >= 75.0 | [g] | requested lambda | 1.15 | [-] | ||||||
| for time | >= 2.0 | [s] | or | ||||||||
| or | passive diagnosis | ||||||||||
| passive diagnosis | passive lambda diagnosis(fuel cut off) (Referenced) | not calibrated | |||||||||
| cumulated O2 mass flow into catalyst | not calibrated | [mg] | additional conditions | ||||||||
| soot mass conditions (Referenced) | not calibrated | ||||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Oxygen Sensor (O2S) rear | P0140 - O2 Sensor Circuit No Activity Detected Bank 1 Sensor 2 | O2S signal check - circuit continuity (open circuit) | sensor signal line | ECM drive mode | detected | 0 [s] multiple | 2 DCY |
|
|||
| difference of sensor voltage with load pulse and voltage without load pulse (mean value of 3 measurements) | >= 2.80 | [V] | normal range conditions | ||||||||
| sensor ground line | battery voltage | > 10.70 | [V] | ||||||||
| internal resistance | not calibrated | [Ohm] | engine running | not calibrated | |||||||
| EGT | not calibrated | [°C] | internal resistance check | successful | |||||||
| within number of successful resistance measurements | > 10.00 | [-] | |||||||||
| time between two successful resistance measurements | <= 8 | [s] | |||||||||
| alternative conditions (diagnostics readiness is set independently of the sensor operating readiness) | |||||||||||
| time after protection heatingmode finished | detected | [s] | |||||||||
| additional time delay | not calibrated | [s] | |||||||||
| O2S is sufficiently electricallyheated | not calibrated | ||||||||||
| within time delay | not calibrated | [s] | |||||||||
| conditions below must be fulfilled | |||||||||||
| for time | >= 200 | [ms] | |||||||||
| internal resistance | <= 900.00 | [Ohm] | |||||||||
| number of resistancemeasurements | >= 3.00 | [-] | |||||||||
| or | |||||||||||
| O2S rear protective heating | finished | ||||||||||
| within time delay | >= 15.0 | [s] | |||||||||
| normalized heating power | >= 0.50 | [-] | |||||||||
| or | |||||||||||
| EGT @ O2S rear | >= 700.0 | [°C] | |||||||||
| for time | >= 25.5 | [s] | |||||||||
| internal sensor resistance issufficiently low | detected | ||||||||||
| within sensor voltage @ rich conditions | 0.50...1.26 | [V] | |||||||||
| or | |||||||||||
| sensor voltage @ leanconditions | <= 0.40 | [V] | |||||||||
| conditions for fault suspicion (only for "sensor signal line") | |||||||||||
| O2S rear signal voltage | 0.40...0.50 | [V] | |||||||||
| for time | >= 3.0 | [s] | |||||||||
| number of loaded measurements | 3 | [-] | |||||||||
| time delay between two load pulses (for confirming suspicion) | 5.0 | [s] | |||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Oxygen Sensor (O2S) rear | P0160 - O2 Sensor Circuit No Activity Detected Bank 2 Sensor 2 | O2S signal check - circuit continuity (open circuit) | sensor signal line | ECM drive mode | detected | 0 [s] multiple | 2 DCY |
|
|||
| difference of sensor voltage with load pulse and voltage without load pulse (mean value of 3 measurements) | >= 2.80 | [V] | normal range conditions | ||||||||
| sensor ground line | battery voltage | > 10.70 | [V] | ||||||||
| internal resistance | not calibrated | [Ohm] | engine running | not calibrated | |||||||
| EGT | not calibrated | [°C] | internal resistance check | successful | |||||||
| within number of successful resistance measurements | > 10.00 | [-] | |||||||||
| time between two successful resistance measurements | <= 8 | [s] | |||||||||
| alternative conditions (diagnostics readiness is set independently of the sensor operating readiness) | |||||||||||
| time after protection heating mode finished | detected | [s] | |||||||||
| additional time delay | not calibrated | ||||||||||
| O2S is sufficiently electrically heated | not calibrated | ||||||||||
| within time delay | not calibrated | [s] | |||||||||
| conditions below must be fulfilled | |||||||||||
| for time | >= 200 | [ms] | |||||||||
| internal resistance | <= 900.00 | [Ohm] | |||||||||
| number of resistance measurements | >= 3.00 | [-] | |||||||||
| or | |||||||||||
| O2S rear protective heating | finished | ||||||||||
| within time delay | >= 15.0 | [s] | |||||||||
| normalized heating power | >= 0.50 | [-] | |||||||||
| or | |||||||||||
| EGT @ O2S rear | >= 700.0 | [°C] | |||||||||
| for time | >= 25.5 | [s] | |||||||||
| internal sensor resistance issufficiently low | detected | ||||||||||
| within sensor voltage @ rich conditions | 0.50...1.26 | [V] | |||||||||
| or | |||||||||||
| sensor voltage @ leanconditions | <= 0.40 | [V] | |||||||||
| conditions for fault suspicion (only for "sensor signal line") | |||||||||||
| O2S rear signal voltage | 0.40...0.50 | [V] | |||||||||
| for time | >= 3.0 | [s] | |||||||||
| number of loadedmeasurements | 3 | [-] | |||||||||
| time delay between two load pulses (for confirming suspicion) | 5.0 | [s] | |||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Oxygen Sensor (O2S) rear | P0138 - O2 Sensor Circuit High Voltage Bank 1 Sensor 2 | O2S signal check - circuit continuity (circuit high) | signal voltage | > 1.26 | [V] | general conditions | 0.2 [s] multiple | 2 DCY |
|
||
| within lambda value | > 1.00 | [-] | cold sensor operation | not calibrated | |||||||
| or | normal range operation | detected | |||||||||
| signal voltage @ cold sensor operation | not calibrated | [V] | engine running | not calibrated | |||||||
| ECM drive mode | detected | ||||||||||
| battery voltage | > 10.70 | [V] | |||||||||
| internal resistance check | successful | ||||||||||
| within number of successful resistance measurements | > 10.00 | ||||||||||
| time between two successful resistance measurements | <= 8 | [s] | |||||||||
| alternative conditions (diagnostics readiness is set independently of the sensor operating readiness) | |||||||||||
| time after protection heatingmode finished | not calibrated | [s] | |||||||||
| additional time delay | not calibrated | [s] | |||||||||
| O2S is sufficiently electricallyheated | not calibrated | ||||||||||
| within time delay | not calibrated | [s] | |||||||||
| conditions below must be fulfilled | |||||||||||
| for time | >= 200 | [ms] | |||||||||
| internal resistance | <= 900.00 | [Ohm] | |||||||||
| number of resistancemeasurements | >= 3.00 | [-] | |||||||||
| or | |||||||||||
| O2S rear protectiveheating | finished | ||||||||||
| within time delay | >= 15.0 | [s] | |||||||||
| normalized heating power | >= 0.50 | ||||||||||
| or | |||||||||||
| EGT @ O2S rear | >= 700.0 | [°C] | |||||||||
| for time | >= 25.5 | [s] | |||||||||
| internal sensor resistance is sufficiently low | detected | ||||||||||
| within sensor voltage @ rich conditions | 0.50...1.26 | [V] | |||||||||
| or | |||||||||||
| sensor voltage @ leanconditions | <= 0.40 | [V] | |||||||||
| Oxygen Sensor (O2S) rear | P0158 - O2 Sensor Circuit High Voltage Bank 2 Sensor 2 | O2S signal check - circuit continuity (circuit high) | signal voltage | > 1.26 | [V] | general conditions | 0.2 [s] multiple | 2 DCY |
|
||
| within lambda value | > 1.00 | cold sensor operation | not calibrated | ||||||||
| or | normal range operation | detected | |||||||||
| signal voltage @ cold sensor operation | not calibrated | [V] | engine running | not calibrated | |||||||
| ECM drive mode | detected | ||||||||||
| battery voltage | > 10.70 | [V] | |||||||||
| internal resistance check | successful | ||||||||||
| within number of succesful resistance measurements | > 10.00 | [-] | |||||||||
| time between two successful resistance measurements | <= 8 | [s] | |||||||||
| alternative conditions (diagnostics readiness is set independently of the sensor operating readiness) | |||||||||||
| time after protection heating mode finished | not calibrated | [s] | |||||||||
| additional time delay | not calibrated | [s] | |||||||||
| O2S is sufficiently electrically heated | not calibrated | ||||||||||
| within time delay | not calibrated | [s] | |||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| conditions below must be fulfilled | |||||||||||
| for time | >= 200 | [ms] | |||||||||
| internal resistance | <= 900.00 | [Ohm] | |||||||||
| number of resistance measurements oh but in the |
>= 3.00 | [-] | |||||||||
| or | |||||||||||
| O2S rear protective heating | finished | ||||||||||
| within time delay | >= 15.0 | [s] | |||||||||
| normalized heating power | >= 0.50 | [-] | |||||||||
| or | |||||||||||
| EGT @ O2S rear | >= 700.0 | [°C] | |||||||||
| for time | >= 25.5 | [s] | |||||||||
| internal sensor resistance is sufficiently low | detected | ||||||||||
| within sensor voltage @ rich conditions | 0.50...1.26 | [V] | |||||||||
| or | |||||||||||
| sensor voltage @ lean conditions | <= 0.40 | [V] | |||||||||
| Oxygen Sensor (O2S) rear | P0137 - O2 Sensor Circuit Low Voltage Bank 1 Sensor 2 | O2S signal check - circuit continuity (circuit low) | diff. sensor voltage with load pulse vs. without load pulse (mean value of 3 measurements) | < 0.01 | [V] | general conditions | 3.0 [s] multiple | 2 DCY |
|
||
| engine running | not calibrated | ||||||||||
| ECM drive mode | detected | ||||||||||
| injection cut off | not active | ||||||||||
| fuel cut off | not calibrated | ||||||||||
| catalyst purge | not active | ||||||||||
| battery voltage | > 10.70 | [V] | |||||||||
| all conditions above must be fulfilled | |||||||||||
| for time | >= 3.0 | [s] | |||||||||
| conditions for fault suspicion | |||||||||||
| O2S rear signal voltage | < 0.03 | [V] | |||||||||
| for time | >= 3.0 | [s] | |||||||||
| number of loadedmeasurements | 3 | [-] | |||||||||
| time delay between two load pulses (for confirming suspicion) | 5.0 | [s] | |||||||||
| Oxygen Sensor (O2S) rear | P0157 - O2 Sensor Circuit Low Voltage Bank 2 Sensor 2 | O2S signal check - circuit continuity (circuit low) | diff. sensor voltage with load pulse vs. without load pulse (mean value of 3 measurements) | < 0.01 | [V] | general conditions | 3.0 [s] multiple | 2 DCY |
|
||
| engine running | not calibrated | ||||||||||
| ECM drive mode | detected | ||||||||||
| injection cut off | not active | ||||||||||
| fuel cut off | not calibrated | ||||||||||
| catalyst purge | not active | ||||||||||
| battery voltage | > 10.70 | [V] | |||||||||
| all conditions above must be fulfilled | |||||||||||
| for time | >= 3.0 | [s] | |||||||||
| conditions for fault suspicion | |||||||||||
| O2S rear signal voltage | < 0.03 | [V] | |||||||||
| for time | >= 3.0 | [s] | |||||||||
| number of loadedmeasurements | 3 | [-] | |||||||||
| time delay between two load pulses (for confirming suspicion) | 5.0 | [s] | |||||||||
Table continues below
| Component / System | DTC / DTC Description | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum. | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Oxygen Sensor (O2S) Heater rear | P0141 - O2 Sensor Heater Circuit Bank 1 Sensor 2 | out of range (during normal heater operation after dew point is exceeded) | internal resistance | > 2200.00...100000.00 | [Ohm] | general conditions | 126.0 [s] multiple | 2 DCY |
|
||
| O2S heated up for time | >= 45.0...45.0 | [s] | |||||||||
| modeled EGT | 250.0...600.0 | [°C] | |||||||||
| modeled EGT | valid | ||||||||||
| IAT upstream throttle | -48.0 | [°C] | |||||||||
| engine off time | > 120.0 | [s] | |||||||||
| counter for engine off time | valid | ||||||||||
| engine | running | ||||||||||
| battery voltage | 10.70...16.10 | [V] | |||||||||
| number of valid internal resistance checks | > 10.00 | [-] | |||||||||
| fuel cut off | not active | ||||||||||
| O2S heater | commanded on | ||||||||||
| conditions after long stop phase | |||||||||||
| time after engine stop | >= 120.0 | [s] | |||||||||
| time after next engine start | >= 30.0 | [s] | |||||||||
| Oxygen Sensor (O2S) Heater rear | P0161 - O2 Sensor Heater Circuit Bank 2 Sensor 2 | out of range (during normal heater operation after dew point is exceeded) | internal resistance | > 2200.00...100000.00 | [Ohm] | general conditions | 126.0 [s] multiple | 2 DCY |
|
||
| O2S heated up for time | >= 45.0...45.0 | [s] | |||||||||
| modeled EGT | 250.0...600.0 | [°C] | |||||||||
| modeled EGT | valid | ||||||||||
| IAT upstream throttle | -48.0 | [°C] | |||||||||
| engine off time | > 120.00 | ||||||||||
| counter for engine off time | valid | ||||||||||
| engine | running | ||||||||||
| battery voltage | 10.70...16.10 | [V] | |||||||||
| number of valid internalresistance checks | > 10.00 | [-] | |||||||||
| fuel cut off | not active | ||||||||||
| O2S heater | commanded on | ||||||||||
| conditions after long stop phase: | |||||||||||
| time after engine stop | >= 120.0 | [s] | |||||||||
| time after next engine start | >= 30.0 | [s] | |||||||||
| Oxygen Sensor (O2S) Heater rear | P0036 - HO2S Heater Control Circuit Bank 1 Sensor 2 | open circuit | signal voltage | > 2.74...3.26 | [V] | general conditions | 0.5 [s] continuous | 2 DCY |
|
||
| signal voltage | <= 4.70...5.40 | [V] | engine speed | >= 0 | [rpm] | ||||||
| battery voltage | > 9.00 | [V] | |||||||||
| battery voltage | not calibrated | [V] | |||||||||
| duty cycle | < 98 | [%] | |||||||||
| conditions for dew point end | |||||||||||
| battery voltage | <= 16.50 | [V] | |||||||||
| ECM postdrive | not detected | ||||||||||
| heating @ ECM predrive | not calibrated | ||||||||||
| or | |||||||||||
| engine | running | ||||||||||
| or | |||||||||||
| drive motor | not equipped | ||||||||||
| protection heating | active | ||||||||||
| heating @ stop phase | |||||||||||
| wall temperature | not calibrated | [°C] | |||||||||
| or | |||||||||||
| EGT | not calibrated | [°C] | |||||||||
| all above conditions (except general conditions) must be fulfilled | |||||||||||
| for time | >= 10.0 | [s] | |||||||||
| fast enable conditions (for sufficient battery voltage or AAT) | |||||||||||
| battery voltage | < 16.00 | [V] | |||||||||
| or | |||||||||||
| AAT | > 143.3 | [°C] | |||||||||
| for time | >= 5.0 | [s] | |||||||||
| conditions above must be fulfilled | |||||||||||
| for time | >= 10.0 | [s] | |||||||||
NO RELATED
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.