Inspection Procedure

2006 Toyota 4Runner SR5, 4.7 T, AWDSECTION Inspection Procedure
  1. CHECK AUTO UP/DOWN FUNCTION 
    1. Check that the AUTO UP/DOWN function operates normally.

    NG: OTHER PROBLEM (See  AUTO UP/DOWN FUNCTION DOES NOT OPERATE   ) 

    OK: GO TO NEXT STEP 

  2. CHECK POWER WINDOW LOCK SWITCH 
    1. Turn the window lock switch OFF and check that the remote UP/DOWN function operates normally.
      Fig 1: Identifying Window Lock Switch OFF
      G04336482Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    OK: END 

    NG: GO TO NEXT STEP 

  3. CHECK MANUAL UP/DOWN FUNCTION 
    1. Check that each door glass can be operated via each power window switch.

    NG: OTHER PROBLEM (See  PROBLEM SYMPTOMS TABLE   ) 

    OK: GO TO NEXT STEP 

  4. INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSY 

    HINT:

    Inspect the switch with which the remote function cannot be operated.

    1. Remove the master switch.
    2. Check the continuity between the terminals of the master switch connector when the switch is operated.
      Fig 2: Identifying Power Window Regulator Master Switch Assy Connector
      G04336483Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard: 

      Passenger switch 

      WINDOW LOCK SWITCH SPECIFIED CONDITION TABLE

      Window Lock Switch Power Window Switch Terminal No. Specified Condition
      OFF UP 6 <==> 13, 15 <==> 1 Continuity
      OFF 13 <==> 1 <==> 15
      DOWN 6 <==> 15, 13 <==> 1
      ON UP 6 <==> 13
      OFF 13 <==> 15
      DOWN 6 <==> 15

      Rear RH switch 

      WINDOW LOCK SWITCH SPECIFIED CONDITION TABLE

      Window Lock Switch Power Window Switch Terminal No. Specified Condition
      OFF UP 6 <==> 18, 16 <==> 1 Continuity
      OFF 18 <==> 1 <==> 6
      DOWN 6 <==> 16, 18 <==> 1
      ON UP 6 <==> 18
      OFF 16 <==> 18
      DOWN 6 <==> 16

      Rear LH switch 

      WINDOW LOCK SWITCH SPECIFIED CONDITION TABLE

      Window Lock Switch Power Window Switch Terminal No. Specified Condition
      OFF UP 6 <==> 12, 10 <==> 1 Continuity
      OFF 12 <==> 1 <==> 10
      DOWN 6 <==> 10, 12 <==> 1
      ON UP 6 <==> 12
      OFF 12 <==> 10
      DOWN 6 <==> 10

    NG: REPLACE POWER WINDOW REGULATOR MASTER SWITCH ASSY 

    OK: REPAIR OR REPLACE HARNESS AND CONNECTOR (MASTER SWITCH <==> EACH POWER WINDOW SWITCH) 

RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.