Inspection Procedure
2004 Toyota Matrix XR, FWD, StandardSECTION Inspection Procedure
WARNING: This page is about a different car, the 2004 Toyota Camry. However, it is still accessible from the selected car via links, so may be relevant.
- INSPECT UN-LOCK WARNING SWITCH ASSY
- Inspect the continuity of the key unlock warning switch continuity.
Standard:
- NG: REPLACE UN-LOCK WARNING SWITCH ASSY
- OK: Go to next step.
- Inspect the continuity of the key unlock warning switch continuity.
- CHECK WIRE HARNESS
- Disconnect the B6 body ECU and U1 unlock warning switch connectors.
- Check the continuity between the disconnected connector.
Standard:
CONDITION CONTINUITY BETWEEN B6-U1Terminal No. Specified Condition B6-19 <--> U1-2 Continuity - Check the continuity between the unlock warning switch disconnected connector and the body ground.
Standard:
KEY UNLOCK WARNING SWITCH CONTINUITY CONDITIONTerminal No. Specified Condition U1-1 <--> Body Ground Continuity
- NG: REPAIR OR REPLACE HARNESS AND CONNECTOR
- OK: Go to next step.
- INSPECT FRONT DOOR COURTESY LAMP SWITCH ASSY
- Inspect the continuity of the key unlock warning switch continuity.
Standard:
- NG: REPLACE FRONT DOOR COURTESY LAMP SWITCH ASSY
- OK: Go to next step.
- Inspect the continuity of the key unlock warning switch continuity.
- CHECK WIRE HARNESS
- Disconnect the B8 body ECU and D6 front door courtesy lamp switch connectors.
- Check the continuity between the disconnected connectors.
Standard:
CONTINUITY CONDITION BETWEEN B8-D6Terminal No. Specified Condition B8-1 <--> D6-1 Continuity
- NG: REPAIR OR REPLACE HARNESS AND CONNECTOR
- OK: REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSY
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.