REPLACEMENT
1. DRAIN HFC-134A (R134A)
a. Turn the A/C switch ON.
b. Operating the cooler compressor at the engine rpm of approx. 1,000 for 5 to 6 mm., circulate the refrigerant and collect compressor oil remaining in each component into the cooler compressor as much as possible.
c. Stop the engine.
d. Let the refrigerant gas out.
SST 07110-58060 (07117-58080, 07117-58090, 07117-78050, 07117-88060, 07117-88070, 07117-88080)
2. CHARGE REFRIGERANT
a. Using a vacuum pump, perform a vacuum purping.

b. Supply refrigerant, HFC-134a (R134a).
Standard: 650 ± 50 g (22.93 ± 1.76 oz.)
SST 07110-58060 (07117-58060, 07117-58070, 07117-58080, 07117-58090, 07117-78050, 07117-88060, 07117-88070, 07117-88080), 07117-48130, 07117-48140
3. WARM UP ENGINE
4. INSPECT LEAKAGE OF REFRIGERANT
1. DRAIN HFC-134A (R134A)
a. Turn the A/C switch ON.
b. Operating the cooler compressor at the engine rpm of approx. 1,000 for 5 to 6 mm., circulate the refrigerant and collect compressor oil remaining in each component into the cooler compressor as much as possible.
c. Stop the engine.
d. Let the refrigerant gas out.
SST 07110-58060 (07117-58080, 07117-58090, 07117-78050, 07117-88060, 07117-88070, 07117-88080)
2. CHARGE REFRIGERANT
a. Using a vacuum pump, perform a vacuum purping.
b. Supply refrigerant, HFC-134a (R134a).
Standard: 650 ± 50 g (22.93 ± 1.76 oz.)
SST 07110-58060 (07117-58060, 07117-58070, 07117-58080, 07117-58090, 07117-78050, 07117-88060, 07117-88070, 07117-88080), 07117-48130, 07117-48140
3. WARM UP ENGINE
4. INSPECT LEAKAGE OF REFRIGERANT
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.