Air Flow Meter

1984 Toyota Cressida 4D WagonSECTION Air Flow Meter

Turn ignition off. Disconnect wiring connector from air flow meter. Using an ohmmeter, measure resistance between each terminal. If resistance values do not meet specifications shown in chart, replace air flow meter.

Fig 1: Measuring Air Flow Meter Resistance
G42168Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
AIR FLOW METER RESISTANCE SPECIFICATIONS

Terminals Condition Ohms
E2 - Vs Flap Closed 20-400
E2 - Vs Flap Open (1) 20-1000
E2 - Vc N/A 200-400
E2 - THA 4°F (-20°C) 10,000-20,000
E2 - THA 32°F (0°C) 4000-7000
E2 - THA 68°F (20°C) 2000-3000
E2 - THA 104°F (40°C) 900-1300
E2 - THA 140°F (60°C) 400-700
E1 - Fc Flap Closed Infinity (4)
E1 - Fc Flap Open Zero
(1) Resistance changes with flap position.