No-Load Performance Test

1990 Suzuki Swift GL, 2D Hatchback, StandardSECTION No-Load Performance Test

Using a jumper wire,connect battery negative terminal to starter housing. Connect battery positive to Ammeter. Connect other side of Ammeter to starter "S" and "BAT" terminals. Starter current draw should be less than 50 amps at 11 Volts. Check that starter rotates smoothly.