Data Monitor: List

2022 Subaru Impreza Base, 4D Sedan, Automatic CVT TransSECTION List
WARNING: This page is about a different car, the 2022 Subaru Crosstrek. However, it is still accessible from the selected car via links, so may be relevant.
Item Contents Standard/Unit Note
In-vehicle Sensor Temperature Display the in-vehicle sensor value. -72.47 - 193.82°C -
Refrigerant Pressure Display the pressure sensor value. 0 - 3.29 MPa -
Quantity of Sunload Display the sunload sensor value. 0 - 4448 W/m2 -
Heater Water Temperature Display the engine coolant temperature. (CAN information) -40.00 - 214°C -
Heater Control Panel Setting Value (Driver's) Display the set temperature of the A/C control panel on driver's seat side. 15 - 90 -
Blower outlet request temperature (Driver's) Internal setting value of the A/C control panel is displayed. -327.68 - 327.67°C -
Air mix door actuator position (driver's side) Display the driver's seat air mix door actuator position information. -32.68 - 133.33 % -
Mode Door Actuator Position Display the mode door actuator position information. -32.68 - 133.33 % -
Fresh/Recircle Air Door Actuator Position Display the intake door actuator position information. -32.68 - 133.33 % -
Target air mix door actuator position (driver's side) Display the driver's seat air mix door actuator target position information. -32.68 - 133.33 % -
Mode Door Actuator Position Target Display the mode door actuator target position information. -32.68 - 133.33 % -
Fresh/Recircle Air Door Actuator Position Target Display the intake door actuator target position information. -32.68 - 133.33 % -
Blower Fan Level Display the blower fan motor speed level. 0 - 255 -
Ambient Air Temperature Display the ambient sensor value. (CAN information) -40 - 80°C -
Compressor operation status Display the operation status of the compressor. OFF/ON -
Blower Fan Operating Condition Display the operation status of the blower fan. MANU/AUTO -
A/C Operating Condition Display the operation status of the compressor. MANU/AUTO -
Fresh/Recircle Air Operating Condition Display the operation status of the FRESH/RECIRC. MANU/AUTO -
Mode Operating Condition Display the operation status of the blow vents. MANU/AUTO -
Rear Defogger Display the operation status of the rear defogger switch. OFF/ON -
Engine Speed Display the engine speed. (CAN information) 0 - 32767 rpm -
Vehicle Speed Display the vehicle speed. (CAN information) 0 - 300 km/h -
Evaporator Temperature Display the evaporator sensor value. -82.48 - 153.55°C -
Evaporator Temperature Target Display the evaporator target temperature. 0 - 20°C -
Discharge Refrigerant Temperature Display the discharged refrigerant temperature. -40 - 214°C -
Inner Condenser Out Refrigerant Temperature Display the interior condenser outlet refrigerant temperature. -40 - 214°C -
External Condenser Out Refrigerant Temperature Display the exterior condenser outlet refrigerant temperature. -40 - 214°C -
Evaporator Out Refrigerant Temperature Display the evaporator outlet refrigerant temperature. -40 - 214°C -
High Pressure Solenoid Valve Drive State Display the drive status of High pressure solenoid valve. OFF/ON -
Low Pressure Solenoid Valve Drive State Display the drive status of Low pressure solenoid valve. OFF/ON -
Cooling Expansion Valve Drive State Display the drive status of Cooling expansion valve. 0 - 100 % -
Heating Expansion Valve Driving State Display the drive status of Heating expansion valve. 0 - 100 % -
Target Air Temperature Behind Inner Condenser Display the target air temperature after the interior condenser. -40 - 214°C -
Estimated Air Temperature Behind Inner Condenser Display the estimated air temperature after the interior condenser. -40 - 214°C -
Operation Cycle State Display the drive cycle status. 01: Cooling 02: Dehumid. (S) 03: Dehumid. (P) 04: Heating 05: Defrosting 06: Idol 07: Initialize -
Electric driven compressor target speed Display the Electric compressor ASSEMBLY target speed. 0 - 32767 rpm -
Blower outlet Door Request Temperature Display the blow vents target temperature. -327.68 - 327.67°C -
PTC operation steps Display the blow vents target temperature. 0 - 3 -
PTC Heater 1 Display operation status of PTC 1st level. Inoperative/Operate -
PTC Heater 2 Display operation status of PTC 2nd level. Inoperative/Operate -
PTC Heater 3 Display operation status of PTC 3rd level. Inoperative/Operate -
Request engine speed Display the request engine speed. 0: Without Request 1: Cooler H 2: Heater H 3: Cooler L 4: Heater L 5: Heater M 6: Heater LL -
Heater core Temp. Heater core sensor reading is displayed. -40 - 214°C -
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.