Diagnostic Method

2016 Subaru Legacy 2.5iSECTION Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
Fig 1: EVAP System Pressure Diagnosis Cycle Graph
G07669738Courtesy of SUBARU OF AMERICA, INC.
Mode Explanation of Mode Diagnosis Period
A Vacuum pump operation confirmation and characteristics stability 7 s or less & 300 s
B Measurement of reference pressure for setting the target negative pressure 40 s or less
C Switching valve operation confirmation 12 s or less
D Clogging of pipe diagnosis and leak pressure measurement 900 s or less
E Reference pressure measurement for judgment 40 s or less
Fig 2: Evaporative Emission System Diagnosis Connection Diagram
G07669739Courtesy of SUBARU OF AMERICA, INC.

Mode A (Vacuum pump operation confirmation and characteristics stability) 

Purpose: Detect the vacuum pump operation trouble.

Judge as NG when the following conditions are established.

Judge as OK if the following conditions are not established, and warm up for five minutes to stabilize the vacuum pump characteristics.

JUDGMENT VALUE

Malfunction Criteria Threshold Value DTC
Pressure sensor output value > -224 Pa (-1.68 mmHg, -0.1 inHg) P2404

Mode B (Measurement of reference pressure for setting the target negative pressure) 

  1. Purpose: Judge the reference pressure stability.

    Judge as NG when the following conditions are established.

    JUDGMENT VALUE

    Malfunction Criteria Threshold Value DTC
    Pressure sensor maximum output value - Pressure sensor minimum output value > 314 Pa (2.355 mmHg, 0.1 inHg) P2404
  2. Purpose: Judge whether the reference pressure is within the normal range, and detect the vacuum pump and orifice malfunctions.

    Judge as NG when the following conditions are established.

    JUDGMENT VALUE

    Malfunction Criteria Threshold Value DTC
    Reference pressure for setting the target negative pressure < Value of Map 2 P2404
      > Value of Map 3  
    Reference pressure for judgment    
    PRESSURE SPECIFICATION

    Barometric pressure kPa (mmHg, inHg) 70 (525, 20.7) 80 (600, 23.6) 90 (675, 26.6) 100 (750, 29.5)
    Reference pressure for setting the target negative pressure kPa (mmHg, inHg) -4 (-29.79, -1.2) -4.1 (-30.593, -1.2) -4.2 (-31.395, -1.2) -4.3 (-32.19, -1.3)
    BAROMETRIC PRESSURE SPECIFICATION

    Barometric pressure kPa (mmHg, inHg) 70 (525, 20.7) 80 (600, 23.6) 90 (675, 26.6) 100 (750, 29.5)
    Reference pressure for judgment kPa (mmHg, inHg) -0.9 (-7.065, -0.3) -1 (-7.86, -0.3) -1.2 (-8.663, -0.3) -1.3 (-9.465, -0.4)

Mode C (Switching valve operation confirmation) 

Purpose: Measure the pressure increase when switching valve is changed from open to close, and detect the stuck to open/close malfunctions of the switching valve.

Judge as NG when the following conditions are established.

JUDGMENT VALUE

Malfunction Criteria Threshold Value DTC
Pressure sensor output value - Reference pressure for setting the target negative pressure < 224 Pa (1.68 mmHg, 0.1 inHg) P2404

Mode D (Clogging of pipe diagnosis and leak pressure measurement) 

  1. Clogging of pipe 

    Purpose: Measure the time required for the evaporative emission system to reach the target negative pressure by the vacuum pump, and detect the clogging of pipe trouble.

    Judge as clogging of pipe malfunction if the evaporative emission system reaches to the target negative pressure within the specified time.

    JUDGMENT VALUE

    Malfunction Criteria Threshold Value DTC
    Time required to reach to the target negative pressure ≤ 27500 ms P1451
    For target vacuum, use one of the followings.
    • Reference pressure for target vacuum setting - value of Map 4
    • -5 kPa (-37.298 mmHg, -1.5 inHg)
       
    PRESSURE SPECIFICATION

    Time of negative pressure introduction ms 0 100000 200000 300000 400000 500000 600000 700000 800000 900000 1000000 1100000 1200000
    Reference pressure for setting the target negative pressure - Pressure sensor output value kPa (mmHg, inHg) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3)
  2. Leak pressure measurement 

    Purpose: Measure the pressure (leak pressure) when the evaporative emission system becomes the negative pressure by the vacuum pump.

    Store the pressure as a leak pressure while the following conditions are met.

    JUDGMENT VALUE

    Conditions for storing the leak pressure Threshold Value
    When any one of the followings is established:  
    • Reference pressure for setting the target negative pressure - Pressure sensor output value
    ≥ Value of Map 4
    • Pressure sensor output value
    < -5 kPa (-37.298 mmHg, -1.5 inHg)
    • Time of negative pressure introduction
    ≥ 900000 ms

Mode E (Measurement of reference pressure for judgment) 

  1. Purpose: Judge the reference pressure stability.

    Judge as NG when the following conditions are established.

    JUDGMENT VALUE

    Malfunction Criteria Threshold Value DTC
    Pressure sensor maximum output value - Pressure sensor minimum output value > 314 Pa (2.355 mmHg, 0.1 inHg) P2404
  2. Purpose: Judge whether the reference pressure is within the normal range, and detect the vacuum pump and orifice malfunctions. Judge the vacuum pump performance stability.

    Judge as NG when the following conditions are established.

    JUDGMENT VALUE

    Malfunction Criteria Threshold Value DTC
    Reference pressure for judgment < Value of Map 5 P2404
      or  
      > Value of Map 6  
    BAROMETRIC PRESSURE SPECIFICATION

    Barometric pressure kPa (mmHg, inHg) 70 (525, 20.7) 80 (600, 23.6) 90 (675, 26.6) 100 (750, 29.5)
    Reference pressure for judgment kPa (mmHg, inHg) -4.5 (-34.02, -1.3) -4.6 (-34.815, -1.4) -4.7 (-35.618, -1.4) -4.9 (-36.42, -1.4)
    BAROMETRIC PRESSURE SPECIFICATION

    Barometric pressure kPa (mmHg, inHg) 70 (525, 20.7) 80 (600, 23.6) 90 (675, 26.6) 100 (750, 29.5)
    Reference pressure for judgment kPa (mmHg, inHg) -0.8 (-6.18, -0.2) -0.9 (-6.983, -0.3) -1 (-7.785, -0.3) -1.1 (-8.58, -0.3)
  3. Purpose: Judge the presence of evaporative emission system leak.

    Judge as NG when the following conditions are established.

    JUDGMENT VALUE

    Malfunction Criteria Threshold Value DTC
    < Large leak (0.04 inch) >   P0455
    Leak pressure ≥ lleakjdg (Pa)  
    lleakjdg = (Reference pressure for judgment) X 0.377 - (-45.5 Pa)    
    < Very small leak (0.02 inch) >   P0456
    Leak pressure > Reference pressure of 0.018 inch  
      and  
      < lleakjdg (Pa)  

Time Needed for Diagnosis:  Approx. 23 min

At next engine start, confirm whether the enable conditions are satisfied even though refueling has been done during soaking, and determine the malfunction.

Malfunction Indicator Light Illumination:  Illuminates when malfunction occurs in 2 continuous driving cycles.

RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.