Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Diagnostic Method
| Mode | Explanation of Mode | Diagnosis Period |
|---|---|---|
| A | Vacuum pump operation confirmation and characteristics stability | 7 s or less & 300 s |
| B | Measurement of reference pressure for setting the target negative pressure | 40 s or less |
| C | Switching valve operation confirmation | 12 s or less |
| D | Clogging of pipe diagnosis and leak pressure measurement | 900 s or less |
| E | Reference pressure measurement for judgment | 40 s or less |
Mode A (Vacuum pump operation confirmation and characteristics stability)
Purpose: Detect the vacuum pump operation trouble.
Judge as NG when the following conditions are established.
Judge as OK if the following conditions are not established, and warm up for five minutes to stabilize the vacuum pump characteristics.
| Malfunction Criteria | Threshold Value | DTC |
|---|---|---|
| Pressure sensor output value | > -224 Pa (-1.68 mmHg, -0.1 inHg) | P2404 |
Mode B (Measurement of reference pressure for setting the target negative pressure)
- Purpose: Judge the reference pressure stability.
Judge as NG when the following conditions are established.
JUDGMENT VALUEMalfunction Criteria Threshold Value DTC Pressure sensor maximum output value - Pressure sensor minimum output value > 314 Pa (2.355 mmHg, 0.1 inHg) P2404 - Purpose: Judge whether the reference pressure is within the normal range, and detect the vacuum pump and orifice malfunctions.
Judge as NG when the following conditions are established.
JUDGMENT VALUEMalfunction Criteria Threshold Value DTC Reference pressure for setting the target negative pressure < Value of Map 2 P2404 > Value of Map 3 Reference pressure for judgment PRESSURE SPECIFICATIONBarometric pressure kPa (mmHg, inHg) 70 (525, 20.7) 80 (600, 23.6) 90 (675, 26.6) 100 (750, 29.5) Reference pressure for setting the target negative pressure kPa (mmHg, inHg) -4 (-29.79, -1.2) -4.1 (-30.593, -1.2) -4.2 (-31.395, -1.2) -4.3 (-32.19, -1.3) BAROMETRIC PRESSURE SPECIFICATIONBarometric pressure kPa (mmHg, inHg) 70 (525, 20.7) 80 (600, 23.6) 90 (675, 26.6) 100 (750, 29.5) Reference pressure for judgment kPa (mmHg, inHg) -0.9 (-7.065, -0.3) -1 (-7.86, -0.3) -1.2 (-8.663, -0.3) -1.3 (-9.465, -0.4)
Mode C (Switching valve operation confirmation)
Purpose: Measure the pressure increase when switching valve is changed from open to close, and detect the stuck to open/close malfunctions of the switching valve.
Judge as NG when the following conditions are established.
| Malfunction Criteria | Threshold Value | DTC |
|---|---|---|
| Pressure sensor output value - Reference pressure for setting the target negative pressure | < 224 Pa (1.68 mmHg, 0.1 inHg) | P2404 |
Mode D (Clogging of pipe diagnosis and leak pressure measurement)
- Clogging of pipe
Purpose: Measure the time required for the evaporative emission system to reach the target negative pressure by the vacuum pump, and detect the clogging of pipe trouble.
Judge as clogging of pipe malfunction if the evaporative emission system reaches to the target negative pressure within the specified time.
JUDGMENT VALUEMalfunction Criteria Threshold Value DTC Time required to reach to the target negative pressure ≤ 27500 ms P1451 For target vacuum, use one of the followings. - Reference pressure for target vacuum setting - value of Map 4
- -5 kPa (-37.298 mmHg, -1.5 inHg)
PRESSURE SPECIFICATIONTime of negative pressure introduction ms 0 100000 200000 300000 400000 500000 600000 700000 800000 900000 1000000 1100000 1200000 Reference pressure for setting the target negative pressure - Pressure sensor output value kPa (mmHg, inHg) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) 0.9 (7.058, 0.3) - Leak pressure measurement
Purpose: Measure the pressure (leak pressure) when the evaporative emission system becomes the negative pressure by the vacuum pump.
Store the pressure as a leak pressure while the following conditions are met.
JUDGMENT VALUEConditions for storing the leak pressure Threshold Value When any one of the followings is established: - Reference pressure for setting the target negative pressure - Pressure sensor output value
≥ Value of Map 4 - Pressure sensor output value
< -5 kPa (-37.298 mmHg, -1.5 inHg) - Time of negative pressure introduction
≥ 900000 ms
Mode E (Measurement of reference pressure for judgment)
- Purpose: Judge the reference pressure stability.
Judge as NG when the following conditions are established.
JUDGMENT VALUEMalfunction Criteria Threshold Value DTC Pressure sensor maximum output value - Pressure sensor minimum output value > 314 Pa (2.355 mmHg, 0.1 inHg) P2404 - Purpose: Judge whether the reference pressure is within the normal range, and detect the vacuum pump and orifice malfunctions. Judge the vacuum pump performance stability.
Judge as NG when the following conditions are established.
JUDGMENT VALUEMalfunction Criteria Threshold Value DTC Reference pressure for judgment < Value of Map 5 P2404 or > Value of Map 6 BAROMETRIC PRESSURE SPECIFICATIONBarometric pressure kPa (mmHg, inHg) 70 (525, 20.7) 80 (600, 23.6) 90 (675, 26.6) 100 (750, 29.5) Reference pressure for judgment kPa (mmHg, inHg) -4.5 (-34.02, -1.3) -4.6 (-34.815, -1.4) -4.7 (-35.618, -1.4) -4.9 (-36.42, -1.4) BAROMETRIC PRESSURE SPECIFICATIONBarometric pressure kPa (mmHg, inHg) 70 (525, 20.7) 80 (600, 23.6) 90 (675, 26.6) 100 (750, 29.5) Reference pressure for judgment kPa (mmHg, inHg) -0.8 (-6.18, -0.2) -0.9 (-6.983, -0.3) -1 (-7.785, -0.3) -1.1 (-8.58, -0.3) - Purpose: Judge the presence of evaporative emission system leak.
Judge as NG when the following conditions are established.
JUDGMENT VALUEMalfunction Criteria Threshold Value DTC < Large leak (0.04 inch) > P0455 Leak pressure ≥ lleakjdg (Pa) lleakjdg = (Reference pressure for judgment) X 0.377 - (-45.5 Pa) < Very small leak (0.02 inch) > P0456 Leak pressure > Reference pressure of 0.018 inch and < lleakjdg (Pa)
Time Needed for Diagnosis: Approx. 23 min
At next engine start, confirm whether the enable conditions are satisfied even though refueling has been done during soaking, and determine the malfunction.
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
NO RELATED
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.