Electrical Specification

2014 Subaru Forester 2.5i Premium, Eng CD FB25BC, Automatic CVT TransSECTION Electrical Specification
Fig 1: AT Shift Lock Control Module Connector Terminal Identification
G08317518Courtesy of SUBARU OF AMERICA, INC.
  • Model without push button ignition switch
    Item Connector No. Terminal No. Input/Output signal
    Measured value and measuring conditions
    Battery power supply B281 6 9 - 16 V
    7
    i84 6
    Ignition power supply B280 32 10 - 15 V when ignition switch is at ACC.
    B281 3 10 - 15 V when ignition switch is at ON or START.
    TCM ("P" range) i84 27 Can not be measured because of digital communication
    35
    Stop light and brake switch B280 10 9 - 16 V when the stop light & brake switch is ON.
    0 V when the stop light & brake switch is OFF.
    "P" range switch B281 18 0 V when select lever is in "P" range.
    9 - 16 V when select lever is in other positions than "P" range.
    Solenoid unit signal B281 5 8.5 - 16 V when shift lock is released.
    0 V when shift lock is operating.
    Key warning switch signal B280 4 9 - 16 V when key is inserted.
    0 V when key is removed.
    Key lock solenoid signal B281 4 7.5 - 16 V when the key is inserted with the select lever shifted in positions other than "P" range.
    0 V at other conditions than above.
    Ground B280 1 -
    B281 31
  • Model with push button ignition switch
    Item Connector No. Terminal No. Input/Output signal
    Measured value and measuring conditions
    Battery power supply B281 6 9 - 16 V
    7
    i84 6
    Ignition power supply B280 32 10 - 15 V when ignition switch is at ACC.
    B281 3 10 - 15 V when ignition switch is at ON or START.
    TCM ("P" range) i84 27 Can not be measured because of digital communication
    35
    Stop light and brake switch B280 10 9 - 16 V when the stop light & brake switch is ON.
    0 V when the stop light & brake switch is OFF.
    "P" range switch B281 18 0 V when select lever is in "P" range.
    9 - 16 V when select lever is in other positions than "P" range.
    Solenoid unit signal B281 5 8.5 - 16 V when shift lock is released.
    0 V when shift lock is operating.
    Ground B280 1 -
    B281 31
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.