Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
SYS.OK|MANUAL.DBβ LIVE
HOMESERVICE MANUALSSUBARU1998LEGACY BRIGHTON WAGON AWD F4-2.2L SOHCREPAIR AND DIAGNOSISHEATING AND AIR CONDITIONINGEXPANSION VALVEDESCRIPTION AND OPERATION
1998 Subaru Legacy Brighton Wagon AWD F4-2.2L SOHC
Expansion Valve: Description and Operation
1998 Subaru Legacy Brighton Wagon AWD F4-2.2L SOHCSECTION Description and Operation
MECHANISM

The expansion valve is attached to the evaporator inlet. It converts high pressure liquid refrigerant which comes from the liquid tank to misty, low pressure refrigerant, and delivers to the evaporator. Being at low pressure and low temperature, the liquid refrigerant evaporates in the evaporator removing heat from the compartment. It automatically controls the flow rate of refrigerant to obtain the necessary cooling ability required by the fluctuating heat load.
The expansion valve is composed of a sensing bulb with a capillary tube that senses the temperature at the evaporator outlet, an equalizer that transmits the pressure of the refrigerant in the evaporator to the diaphragm and other parts such as the spring, ball and diaphragm.
FUNCTION

The operation of the internal equalizer type is as shown.
The expansion valve opening is automatically controlled by the functions of three force: the pressure of the temperature-sensing bulb (P(1)) containing a liquid or vapor, the pressure at the expansion valve outlet (P(2)), and the force of the spring (F).
Temperature-sensing bulb pressure (P(1)) ...... Forces the diaphragm downward (opens the valve).
Pressure at the expansion valve outlet (P(2)) ...... Forces the diaphragm upward (closes the valve).
Force of the spring (F) ...... Forces the ball upward (closes the valve).
A: Condition of the valve with the compressor in off.
Since the temperature around the evaporator is constant, the pressure in the evaporator is equal to that of the temperature-sensing bulb. Therefore, the force of the spring is greater than these pressures and the pressures are in the following condition:
P(1) = P(2)
P(1) < P(2) + F
That means, the valve is closed with the ball pushed upward.
B: Operation of the valve with the sensing bulb at low temperatures (When the temperature is low at evaporator outlet)
As the temperature of the compartment decreases; the heat load applied to the evaporator becomes less, and the temperatures at the evaporator outlet, and the sensing bulb drop. Accordingly, the valve tends to close, reducing the amount of refrigerant.
P(1) < P(2) + F
The amount of refrigerant is reduced.
C: Operation of valve with the sensing bulb at high temperatures
(When the temperature is high at evaporator outlet)
As the temperature of the compartment rises, the heat load applied to the evaporator becomes greater, and the temperatures at the evaporator outlet, and the sensing bulb increase. Therefore, the valve tends to open, allowing more refrigerant to flow.
P(1) > P(2) + F
The amount of refrigerant is increased.
The expansion valve is attached to the evaporator inlet. It converts high pressure liquid refrigerant which comes from the liquid tank to misty, low pressure refrigerant, and delivers to the evaporator. Being at low pressure and low temperature, the liquid refrigerant evaporates in the evaporator removing heat from the compartment. It automatically controls the flow rate of refrigerant to obtain the necessary cooling ability required by the fluctuating heat load.
The expansion valve is composed of a sensing bulb with a capillary tube that senses the temperature at the evaporator outlet, an equalizer that transmits the pressure of the refrigerant in the evaporator to the diaphragm and other parts such as the spring, ball and diaphragm.
FUNCTION
The operation of the internal equalizer type is as shown.
The expansion valve opening is automatically controlled by the functions of three force: the pressure of the temperature-sensing bulb (P(1)) containing a liquid or vapor, the pressure at the expansion valve outlet (P(2)), and the force of the spring (F).
Temperature-sensing bulb pressure (P(1)) ...... Forces the diaphragm downward (opens the valve).
Pressure at the expansion valve outlet (P(2)) ...... Forces the diaphragm upward (closes the valve).
Force of the spring (F) ...... Forces the ball upward (closes the valve).
A: Condition of the valve with the compressor in off.
Since the temperature around the evaporator is constant, the pressure in the evaporator is equal to that of the temperature-sensing bulb. Therefore, the force of the spring is greater than these pressures and the pressures are in the following condition:
P(1) = P(2)
P(1) < P(2) + F
That means, the valve is closed with the ball pushed upward.
B: Operation of the valve with the sensing bulb at low temperatures (When the temperature is low at evaporator outlet)
As the temperature of the compartment decreases; the heat load applied to the evaporator becomes less, and the temperatures at the evaporator outlet, and the sensing bulb drop. Accordingly, the valve tends to close, reducing the amount of refrigerant.
P(1) < P(2) + F
The amount of refrigerant is reduced.
C: Operation of valve with the sensing bulb at high temperatures
(When the temperature is high at evaporator outlet)
As the temperature of the compartment rises, the heat load applied to the evaporator becomes greater, and the temperatures at the evaporator outlet, and the sensing bulb increase. Therefore, the valve tends to open, allowing more refrigerant to flow.
P(1) > P(2) + F
The amount of refrigerant is increased.
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.