Circuit/System Testing: Restriction

2009 Saturn Astra XR, 2D Hatchback, AutomaticSECTION Restriction

With the engine running, the EVAP canister vent solenoid valve open, and the EVAP canister purge solenoid valve commanded to 100 percent, the fuel tank vacuum should not increase to more than 4.0 volts.

  • If the fuel tank vacuum is greater than the specified value, isolate the restriction by disconnecting one component at a time while the EVAP canister purge solenoid valve is commanded to 100 percent and the vent valve is open.

FTP Sensor

  1. Ignition OFF, disconnect the harness connector at the FTP sensor.
  2. Ignition OFF, test for less than 5 ohms between the low reference circuit terminal 2 and ground.
    • If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the FTP sensor.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.