Ground Circuits

1991 Pontiac 6000 SESECTION Ground Circuits
  1. Using an ohmmeter, check for continuity to ground on control unit ground terminals. Use appropriate schematic in WIRING DIAGRAMS article to determine ECM ground terminals. Resistance to ground should be zero ohms. If reading is other than zero ohms, repair open to ground.
  2. Using a DVOM, touch negative lead of voltmeter to a good ground. Touch positive lead of voltmeter to each ground terminal. With vehicle running, voltmeter should indicate less than one volt. If voltmeter reading is one volt or more, check for open, corrosion or loose connection on ground lead.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.