Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn A/C switch and blower fan switch OFF.
- Turn ignition switch OFF.
- Check ground connection E24. Refer to Ground Inspection in Intermittent Incident .
Is the inspection result normal?
>>
GO TO 2.
>>
Repair or replace ground connection.
- CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY
- Disconnect refrigerant pressure sensor harness connector.
- Turn ignition switch ON.
- Check the voltage between refrigerant pressure sensor harness connector and ground.
+ - Voltage (Approx.) Refrigerant pressure sensor Connector Terminal E48 3 Ground 5 V
Is the inspection result normal?
>>
GO TO 5.
>>
GO TO 3.
- CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
Refrigerant pressure sensor ECM Continuity Connector Terminal Connector Terminal E48 3 F79 136 Existed - Also check harness for short to power and short to ground.
Is the inspection result normal?
>>
GO TO 4.
>>
Repair or replace error-detected parts.
- CHECK SENSOR POWER SUPPLY 2 CIRCUIT
Refer to Diagnosis Procedure .
Is the inspection result normal?
>>
Perform the trouble diagnosis for ECM power supply circuit. Refer to Diagnosis Procedure .
>>
Repair or replace error-detected parts.
- CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
Refrigerant pressure sensor ECM Continuity Connector Terminal Connector Terminal E48 1 F79 125 Existed - Also check harness for short to power and short to ground.
Is the inspection result normal?
>>
GO TO 6.
>>
Repair or replace error-detected parts.
- CHECK REFRIGERANT PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
Refrigerant pressure sensor ECM Continuity Connector Terminal Connector Terminal E48 2 F79 108 Existed - Also check harness for short to power and short to ground.
Is the inspection result normal?
>>
GO TO 7.
>>
Repair or replace error-detected parts.
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
- CHECK INTERMITTENT INCIDENT
Refer to Intermittent Incident .
Is the inspection result normal?
>>
Replace refrigerant pressure sensor. Refer to Removal and Installation .
>>
Repair or replace error-detected parts.
NO RELATED
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.