HOMESERVICE MANUALSMINI2005COOPER S CONVERTIBLE (R52) L4-1.6L SC (W11)REPAIR AND DIAGNOSISPOWERTRAIN MANAGEMENTTECHNICAL SERVICE BULLETINSCUSTOMER INTERESTENGINE CONTROLS - MIL ON/FAULT CODE 130 SET
2005 Mini Cooper S Convertible (R52) L4-1.6L SC (W11)
Engine Controls - MIL ON/Fault Code 130 Set
2005 Mini Cooper S Convertible (R52) L4-1.6L SC (W11)SECTION Engine Controls - MIL ON/Fault Code 130 Set
SI M12 06 07
Engine Electrical Systems
September 2010
Technical Service
This Service Information bulletin supersedes SI M12 06 07 dated May 2007.
[NEW] designates changes to this revision
SUBJECT
Service Engine Soon Lamp Illuminated: FC 130 Oxygen Sensor
MODEL
R50 (Cooper) vehicles equipped with the W10 engine
R52 (Cooper and Cooper S) vehicles equipped with the W10 and W11 engines
R53 (Cooper S) vehicles equipped with the W11 engine
SITUATION
The customer complains that the "Service Engine Soon" lamp is illuminated. The following fault is stored in DME memory:
FC 130 Oxygen sensor (bank 1, before cat.) - malfunction, no signal detected
CAUSE
Internal oxygen sensor signal connection issue resulting in a sporadic open circuit
PROCEDURE
Replace the pre-cat oxygen sensor.

PARTS INFORMATION


WARRANTY INFORMATION
Engine Electrical Systems
September 2010
Technical Service
This Service Information bulletin supersedes SI M12 06 07 dated May 2007.
[NEW] designates changes to this revision
SUBJECT
Service Engine Soon Lamp Illuminated: FC 130 Oxygen Sensor
MODEL
R50 (Cooper) vehicles equipped with the W10 engine
R52 (Cooper and Cooper S) vehicles equipped with the W10 and W11 engines
R53 (Cooper S) vehicles equipped with the W11 engine
SITUATION
The customer complains that the "Service Engine Soon" lamp is illuminated. The following fault is stored in DME memory:
FC 130 Oxygen sensor (bank 1, before cat.) - malfunction, no signal detected
CAUSE
Internal oxygen sensor signal connection issue resulting in a sporadic open circuit
PROCEDURE
Replace the pre-cat oxygen sensor.
PARTS INFORMATION
WARRANTY INFORMATION
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.