Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
SYS.OK|MANUAL.DBβ LIVE
HOMESERVICE MANUALSMERCURY2009MILAN PREMIER, 3.0 1, AWDREPAIR AND DIAGNOSISEXTERNAL PAGESDIFFERENT CARSECTION 1646 (HVAC - CLIMATE CONTROL SYSTEM)SPECIFICATIONSTORQUE SPECIFICATIONS
2009 Mercury Milan Premier, 3.0 1, AWD
Torque Specifications
2009 Mercury Milan Premier, 3.0 1, AWDSECTION Torque Specifications
WARNING: This page is about a different car, the 2010 Mercury Mariner and 2010 Ford Escape. However, it is still accessible from the selected car via links, so may be relevant.
TORQUE SPECIFICATIONS
| Description | Nm | lb-ft | lb-in |
|---|---|---|---|
| A/C clutch disc and hub bolt (2.3L, 3.0L [4V]) | 20 | - | 177 |
| A/C compressor bolts | 25 | 18 | - |
| A/C compressor bracket bolts (hybrid) | 25 | 18 | - |
| A/C compressor discharge fitting nut | 15 | - | 133 |
| A/C compressor suction fitting nut | 15 | - | 133 |
| A/C pressure relief valve (2.5L, 3.0L [4V]) | 10 | - | 89 |
| A/C pressure transducer | 8 | - | 71 |
| Air inlet duct screws | 3 | - | 27 |
| Air inlet mode door actuator screws | 3 | - | 27 |
| Auxiliary coolant flow pump bolts (hybrid) | 4 | - | 35 |
| Blower motor resistor screws | 3 | - | 27 |
| Blower motor speed control screws | 3 | - | 27 |
| Condenser bolts | 7 | - | 62 |
| Condenser inlet fitting nut | 15 | - | 133 |
| Condenser outlet fitting nut | 15 | - | 133 |
| Defrost/panel/floor mode door actuator screws | 3 | - | 27 |
| Dual-function pressure switch | 8 | - | 71 |
| Dual-function pressure switch Schrader-type valve | 0.5 | - | 5 |
| Evaporator inlet line bracket nut (hybrid) | 7 | - | 62 |
| Evaporator inlet line bracket nut (non-hybrid) | 8 | - | 71 |
| Evaporator outlet line fitting nut (hybrid) | 15 | - | 133 |
| Evaporator-to-compressor suction line bracket nut | 7 | - | 62 |
| Heater core and evaporator core housing nuts | 9 | - | 80 |
| Heater core bracket screw | 3 | - | 27 |
| High-pressure Schrader-type valve | 3.4 | - | 30 |
| High-pressure service gauge port valve cap | 0.8 | - | 7 |
| Low-charge protection switch | 3 | - | 27 |
| Low-charge protection switch Schrader-type valve | 0.5 | - | 5 |
| Low-pressure Schrader-type valve | 2.26 | - | 20 |
| Low-pressure service gauge port valve cap | 0.8 | - | 7 |
| Motor Electronics (M/E) cooler pump bolts | 20 | - | 177 |
| Plenum chamber screws | 3 | - | 27 |
| Radiator bracket bolt | 8 | - | 71 |
| Receiver/drier fitting studs | 6 | - | 53 |
| Receiver/drier inlet fitting nut | 15 | - | 133 |
| Receiver/drier nuts (non-hybrid) | 8 | - | 71 |
| Receiver/drier nuts (hybrid) | 7 | - | 62 |
| Receiver/drier outlet fitting nut | 15 | - | 133 |
| Temperature blend door actuator screws | 3 | - | 27 |
| Thermostatic Expansion Valve (TXV) bolts | 8 | - | 71 |
| TXVΒ fitting nut | 15 | - | 133 |
| TXVΒ fitting stud | 6 | - | 53 |
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.