Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
SYS.OK|MANUAL.DBβ LIVE
HOMESERVICE MANUALSMERCURY2009MILAN PREMIER, 3.0 1, AWDREPAIR AND DIAGNOSISEXTERNAL PAGESDIFFERENT CARSECTION 1108 (HVAC CONTROL SYSTEM)SPECIFICATIONSTORQUE SPECIFICATIONS
2009 Mercury Milan Premier, 3.0 1, AWD
Torque Specifications
2009 Mercury Milan Premier, 3.0 1, AWDSECTION Torque Specifications
WARNING: This page is about a different car, the 2008 Mercury Mariner and 2008 Ford Escape. However, it is still accessible from the selected car via links, so may be relevant.
TORQUE SPECIFICATIONS
| Description | Nm | lb-ft | lb-in |
|---|---|---|---|
| A/C clutch disc and hub bolt (2.3L, 3.0L [4V]) | 20 | 15 | - |
| A/C clutch disc and hub nut (hybrid) | 26 | 19 | - |
| A/C compressor bolts | 25 | 18 | - |
| A/C compressor discharge fitting nut | 15 | 11 | - |
| A/C compressor manifold bolt (hybrid) | 20 | 15 | - |
| A/C compressor suction fitting nut | 15 | 11 | - |
| A/C pressure relief valve (2.3L, 3.0L [4V]) | 10 | - | 89 |
| Air inlet duct screws | 2 | - | 18 |
| Air inlet mode door actuator screws | 3 | - | 27 |
| Auxiliary coolant flow pump bolts (hybrid) | 4 | - | 35 |
| Auxiliary evaporator inlet line fitting nut (hybrid) | 8 | - | 71 |
| Auxiliary evaporator outlet line fitting nut (hybrid) | 15 | 11 | - |
| Blower motor resistor screws | 3 | - | 27 |
| Blower motor speed control screws | 3 | - | 27 |
| Compressor manifold and tube assembly bracket nut | 8 | - | 71 |
| Condenser bolts | 7 | - | 62 |
| Condenser inlet fitting nut | 15 | 11 | - |
| Condenser outlet fitting nut | 15 | 11 | - |
| Defrost/panel/floor mode door actuator screws | 3 | - | 27 |
| Dual-function pressure switch | 8 | - | 71 |
| Dual-function pressure switch Schrader-type valve | 0.5 | - | 5 |
| Evaporator inlet line bracket nut | 8 | - | 71 |
| Evaporator outlet line fitting nut (hybrid) | 15 | 11 | - |
| Heater core and evaporator core housing nuts | 9 | - | 80 |
| Heater core bracket screw | 3 | - | 27 |
| High-pressure Schrader-type valve | 3.4 | - | 30 |
| High-pressure service gauge port valve cap | 0.8 | - | 7 |
| Low-charge protection switch | 3 | - | 27 |
| Low-charge protection switch Schrader-type valve | 0.5 | - | 5 |
| Low-pressure Schrader-type valve | 2.26 | - | 20 |
| Low-pressure service gauge port valve cap | 0.8 | - | 7 |
| Passenger zone valve bracket nut (hybrid) | 7 | - | 62 |
| Passenger zone valve (tube-O) fittings (hybrid) | 17 | 13 | - |
| Plenum chamber screws | 3 | - | 27 |
| Radiator bracket bolt | 8 | - | 71 |
| Receiver/drier fitting studs | 6 | - | 53 |
| Receiver/drier inlet fitting nut | 15 | 11 | - |
| Receiver/drier nuts (2.3L of 3.0L [4V]) | 8 | - | 71 |
| Receiver/drier nuts (hybrid) | 7 | - | 62 |
| Receiver/drier outlet fitting nut | 15 | 11 | - |
| Temperature blend door actuator screws | 3 | - | 27 |
| Thermal protection switch bolt | 6 | - | 53 |
| Thermostatic expansion valve (TXV) bolts | 8 | - | 71 |
| TXV fitting nut | 15 | 11 | - |
| TXV fitting stud | 6 | - | 53 |
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.