The dual-function pressure switch is located on the receiver drier and includes 2 separate sets of contacts that are opened at 2 different pressures.
The first set of contacts in the dual-function pressure switch is used to interrupt A/C compressor operation in the event of excessively high discharge pressure in the high-pressure side of the refrigerant system. The PCM monitors the first set of contacts in the dual-function pressure switch in-series with the low-charge protection switch. When the contacts are open, the PCM will disengage the A/C compressor clutch.
The second set of contacts in the dual-function pressure switch is used by the PCM to engage the high-speed cooling fan. The PCM monitors the second set of contacts through the A/C pressure (ACP) circuit. When the A/C pressure rises above a preset level, the second set of contacts will close and the high-speed cooling fan will be engaged.
The dual-function pressure switch is installed on a Schrader-type valve core fitting on the receiver/drier. It is not necessary to recover the refrigerant to remove the dual-function pressure switch.
Low-Charge Protection Switch

The low-charge protection switch is installed on the evaporator outlet line to cycle the A/C compressor off in the event of a low refrigerant charge. The PCM monitors the low-charge protection switch in-series with the dual-function pressure switch. When the low-side pressure drops below acceptable levels, the low-charge protection switch contacts open. When the low-charge protection switch contacts are open, the PCM will disengage the A/C compressor clutch.
The low-charge protection switch is installed on a Schrader-type valve core fitting on the evaporator outlet line. It is not necessary to recover the refrigerant to remove the low-charge protection switch.
The dual-function pressure switch is located on the receiver drier and includes 2 separate sets of contacts that are opened at 2 different pressures.
The first set of contacts in the dual-function pressure switch is used to interrupt A/C compressor operation in the event of excessively high discharge pressure in the high-pressure side of the refrigerant system. The PCM monitors the first set of contacts in the dual-function pressure switch in-series with the low-charge protection switch. When the contacts are open, the PCM will disengage the A/C compressor clutch.
The second set of contacts in the dual-function pressure switch is used by the PCM to engage the high-speed cooling fan. The PCM monitors the second set of contacts through the A/C pressure (ACP) circuit. When the A/C pressure rises above a preset level, the second set of contacts will close and the high-speed cooling fan will be engaged.
The dual-function pressure switch is installed on a Schrader-type valve core fitting on the receiver/drier. It is not necessary to recover the refrigerant to remove the dual-function pressure switch.
Low-Charge Protection Switch
The low-charge protection switch is installed on the evaporator outlet line to cycle the A/C compressor off in the event of a low refrigerant charge. The PCM monitors the low-charge protection switch in-series with the dual-function pressure switch. When the low-side pressure drops below acceptable levels, the low-charge protection switch contacts open. When the low-charge protection switch contacts are open, the PCM will disengage the A/C compressor clutch.
The low-charge protection switch is installed on a Schrader-type valve core fitting on the evaporator outlet line. It is not necessary to recover the refrigerant to remove the low-charge protection switch.
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.