Output Test Mode

1996 Mercury Sable GS, 4D Wagon, AX4NSECTION Output Test Mode

This mode allows a technician to energize and de-energize most of the system output actuators on command. After accessing OUTPUT TEST MODE, outputs and cooling fans can be turned on and off separately.

To access OUTPUT TEST MODE, turn ignition switch to OFF position. Ensure test equipment is properly attached. Program scan tester using the following steps:

  • Select vehicle and engine selection menu. See Figure.
  • Select year, engine, model and any additional information requested by scan tester.
  • Follow operating instructions from scan tester menu.
  • Select DIAGNOSTIC DATA LINK.
  • Select PCM - POWERTRAIN CTRL MODULE.
  • Select DIAGNOSTIC TEST MODE.
  • Select ACTIVE COMMAND MODE.
  • Select OUTPUT TEST MODE.
  • Turn ignition on.
  • Follow operating instructions from scan tester menu.
  • Select either LOW SPEED FAN, HIGH SPEED FAN or ALL ON mode.
  • Select START to turn outputs on. This step may cause link up to PIDs.
  • Select STOP to turn outputs off.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.