Vacuum Operated Thermostatic

1990 Mercury Cougar/XR7 V6-232 3.8LSECTION Vacuum Operated Thermostatic

This test must be performed with ambient air temperature below 60° F. Do not immerse any part of the vacuum operated duct and valve assembly in water.
1. On systems with Cold Weather Modulator, bypass the modulator by connecting the two vacuum lines from the modulator.
2. Apply parking brake and block wheels, then remove air cleaner cover and element. Check heat riser tube and zip tube for proper installation or damage. Repair or replace as necessary.
3. Remove components necessary to observe position of duct door. On vacuum operated units, disconnect vacuum line at duct and valve. Check that duct door is in the open (fresh air side) position. If not, check for binding or sticking. Repair or replace as necessary.
4. Place a magnetic based thermometer as near as possible to temperature sensor on inlet side. If air cleaner housing is aluminum, use tape to secure thermometer. Do not allow magnet to touch temperature sensor.
5. Start engine. If duct door is in the heat on position, proceed to step 7. If duct door is in the heat off position, turn engine off. Cool sensor temperature by spraying with Refrigerant 12 for 20 seconds. Do not spray refrigerant with engine running, as any refrigerant drawn into the carburetor and burned in the engine will produce poisonous phosgene gas. Conduct this procedure in well ventilated area.
6. Restart engine. If duct door is in the heat off position during idle, check vacuum hoses.
7. Reinstall air cleaner cover without wing nut. With engine running, observe duct door. When door starts to open, remove air cleaner cover and note temperature reading on thermometer. Temperature reading should not exceed the following specifications:
a. For brown color coded sensors, temperature should not exceed 75° F.
b. For black or pink color coded sensors, temperature should not exceed 90° F.
c. For blue or yellow or green color coded sensors, temperature should not exceed 105° F.
d. If temperatures are greater than those specified above, replace sensor.
8. If duct door does not start to open within 5 minutes after performing step, remove air cleaner cover and note temperature. If temperature is less than specified above, the temperature is insufficient to operate the duct door. Reinstall air cleaner cover without wing nut and continue to run engine until specified temperature is reached. If duct door has not started to open by then, replace sensor.



RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.