Check For VBAT To EDIS Module (NAVAJO)

1991 Mazda RX-7 TurboSECTION Check For VBAT To EDIS Module (NAVAJO)

Turn key off and disconnect ECA, set DVOM to 20-volt scale. Turn key on. Measure voltage between breakout box pins No. (+) J51 (VBAT E) and (-) J7 (BAT negative). If voltage is greater than 10.5 volts, go to CHECK FOR GROUND OPEN TO EDIS MODULE (NAVAJO). If voltage is 10.5 volts or less, repair open or short in circuit from ignition switch.

RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.