Electrical Circuit Inspection Procedure

2015 Kia Rio SX, 4D HatchbackSECTION Electrical Circuit Inspection Procedure
  • Check Open Circuit
    1. Procedures for Open Circuit
      1. Continuity Check
      2. Voltage Check

      If an open circuit occurs (as seen in Fig 1), it can be found by performing Step 2 (Continuity Check Method) or Step  3 (Voltage Check Method) as shown in illustration below.

      Fig 1: Checking For Open Circuit
      G08321346Courtesy of KIA MOTORS AMERICA, INC.
    2. Continuity Check Method
      NOTE: When measuring for resistance, lightly shake the wire harness above and below or from side to side.

      Specification (Resistance) 

      1Ω or less → Normal Circuit

      1MΩ or Higher → Open Circuit

      1. Disconnect connectors (A), (C) and measure resistance between connector (A) and (C) as shown in Fig 2. In Fig 2 the measured resistance of line 1 and 2 is higher than 1MΩ and below 1 Ω respectively. Specifically the open circuit is line 1 (Line 2 is normal). To find exact break point, check sub line of line 1 as described in next step.
        Fig 2: Measuring Resistance Between Connectors A And C
        G08321347Courtesy of KIA MOTORS AMERICA, INC.
      2. Disconnect connector (B), and measure for resistance between connector (C) and (B1) and between (B2) and (A) as shown in Fig 3.

      In this case the measured resistance between connector (C) and (B1) is higher than 1MΩ and the open circuit is between terminal 1 of connector (C) and terminal 1 of connector (B1).

      Fig 3: Measuring Resistance Between Connector C, B1 And B2, A
      G08321348Courtesy of KIA MOTORS AMERICA, INC.
    3. Voltage Check Method
      1. With each connector still connected, measure the voltage between the chassis ground and terminal 1 of each connectors (A), (B) and (C) as shown in Fig 4.

      The measured voltage of each connector is 5V, 5V and 0V respectively. So the open circuit is between connector (C) and (B).

      Fig 4: Measuring Voltage Between Chassis Ground And Terminal 1 Of Connectors A, B And C
      G08321349Courtesy of KIA MOTORS AMERICA, INC.
  • Check Short Circuit 
    1. Test Method for Short to Ground Circuit
      1. Continuity Check with Chassis Ground

      If short to ground circuit occurs as shown in Fig 5], the broken point can be found by performing Step 2 (Continuity Check Method with Chassis Ground) as shown in illustration below.

      Fig 5: Checking For Short To Ground Circuit
      G08321350Courtesy of KIA MOTORS AMERICA, INC.
    2. Continuity Check Method (with Chassis Ground)
      NOTE: Lightly shake the wire harness above and below, or from side to side when measuring the resistance.

      Specification (Resistance) 

      1Ω or less → Short to Ground Circuit

      1MΩ or Higher → Normal Circuit

      1. Disconnect connectors (A), (C) and measure for resistance between connector (A) and Chassis Ground as shown in Fig 6.

        The measured resistance of line 1 and 2 in this example is below 1 Ω and higher than 1MΩ respectively. Specifically the short to ground circuit is line 1 (Line 2 is normal). To find exact broken point, check the sub line of line 1 as described in the following step.

        Fig 6: Measuring Resistance Between Connector A And Chassis Ground
        G08321351Courtesy of KIA MOTORS AMERICA, INC.
      2. Disconnect connector (B), and measure the resistance between connector (A) and chassis ground, and between (B1) and chassis ground as shown in Fig 7.

      The measured resistance between connector (B1) and chassis ground is 1Ω or less. The short to ground circuit is between terminal 1 of connector (C) and terminal 1 of connector (B1).

      Fig 7: Measuring Resistance Between Connector A, B1 And Chassis Ground
      G08321352Courtesy of KIA MOTORS AMERICA, INC.
  • Testing For Voltage Drop 

    This test checks for voltage drop along a wire, or through a connection or switch.

    1. Connect the positive lead of a voltmeter to the end of the wire (or to the side of the connector or switch) closest to the battery.
    2. Connect the negative lead to the other end of the wire. (or the other side of the connector or switch)
    3. Operate the circuit.
    4. The voltmeter will show the difference in voltage between the two points. A difference, or drop of more than 0.1 volts (50mV in 5V circuits), may indicate a problem. Check the circuit for loose or dirty connections.
Fig 8: Checking Voltage Drop
G08321353Courtesy of KIA MOTORS AMERICA, INC.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.