Installation Procedure

2006 Isuzu Ascender S, 5.3 M, 4WDSECTION Installation Procedure
WARNING: This page is about a different car, the 2009 Pontiac Torrent and 2009 Chevrolet Equinox. However, it is still accessible from the selected car via links, so may be relevant.
  1. Lubricate the CMP sensor O-rings with clean engine oil.
  2. Fig 1: View Of CMP Sensor
    GM1087797Courtesy of GENERAL MOTORS CORP.
  3. Install the CMP sensor (1).
  4. CAUTION: Refer to Fastener Caution .
  5. Install the CMP sensor bolt (2).

    Tighten:Β  Tighten the bolt to 10 N.m (89 lb in).

  6. Connect the engine wiring harness electrical connector to the CMP sensor.
  7. Install the air cleaner inlet duct. Refer to Air Cleaner Inlet Duct ReplacementΒ .