Pressure Testing
1997 Isuzu Oasis SSECTION Pressure Testing
- Disconnect negative battery terminal. Release fuel pressure. See FUEL SYSTEM PRESSURE RELEASE . Remove 12-mm sealing nut and washer(s) and connect Fuel Pressure Gauge (07406-0040001 ). Reconnect negative battery terminal. Disconnect vacuum hose from fuel pressure regulator and pinch closed. Start engine, and read fuel pressure. If engine will not start, turn ignition on, wait for 2 seconds, turn ignition off, then on again and read fuel pressure.
- With engine idling, reconnect vacuum hose to fuel pressure regulator and note fuel pressure. Both gauge readings should be within specification. See REGULATED FUEL PRESSURE . If fuel pressure is higher than specified, check for pinched or clogged fuel return hose or defective fuel pressure regulator. If fuel pressure is lower than specified, check for clogged fuel filter, defective fuel pressure regulator or fuel line leakage.
- Relieve fuel pressure and remove gauge. Reinstall 12-mm sealing nut using new washer(s). Tighten 12-mm sealing nut to 16 ft. lbs. (22 N.m). Start engine and check for leaks.REGULATED FUEL PRESSURE AT IDLE
Application psi (kg/cm2 ) Vacuum Hose Disconnected & Pinched 38-46 (2.7-3.2) Vacuum Hose Connected 30-37 (2.1-2.6)
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.