Diagnosis Procedure

2019 Infiniti Q70 3.7 Luxe, AWDSECTION Diagnosis Procedure
WARNING: This page is about a different variant/trim than selected.
  1. CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT 
    1. Disconnect refrigerant pressure sensor harness connector.
    2. Turn ignition switch ON.
    3. Check the voltage between refrigerant pressure sensor harness connector and ground.

      Refrigerant pressure sensor

      Ground

      Voltage (V)

      Connector

      Terminal

      E77

      3

      Ground

      Approx. 5 V

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    GO TO 2.

  2. DETECT MALFUNCTIONING PART 

    Check the following.

    • Harness for open or short between ECM and refrigerant pressure sensor
    • Loose or poor connection for each connector and harness

    Repair open circuit, short to ground or short to power in harness or connectors.

  3. CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT 
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.

      Refrigerant pressure sensor

      ECM

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      E77

      1

      F116

      13

      Existed

    4. Also check harness for short to ground and short to power.

    Is the inspection result normal?

    YES

    GO TO 5.

    NO

    GO TO 4.

  4. DETECT MALFUNCTIONING PART 

    Check the following.

    • Harness for open or short between ECM and refrigerant pressure sensor
    • Loose or poor connection for each connector and harness

    Repair open circuit, short to ground or short to power in harness or connectors.

  5. CHECK REFRIGERANT PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT 
    1. Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.

      Refrigerant pressure sensor

      ECM

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      E77

      2

      F116

      12

      Existed

    2. Also check harness for short to ground and short to power.

    Is the inspection result normal?

    YES

    GO TO 7.

    NO

    GO TO 6.

  6. DETECT MALFUNCTIONING PART 

    Check the following.

    • Harness for open or short between ECM and refrigerant pressure sensor
    • Loose or poor connection for each connector and harness

    Repair open circuit, short to ground or short to power in harness or connectors.

  7. CHECK INTERMITTENT INCIDENT 

    Refer to Intermittent Incident .

    Is the inspection result normal?

    YES

    Replace refrigerant pressure sensor. Refer to Removal and Installation .

    NO

    Repair or replace malfunctioning part.

RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.