Solenoid valve: Specification: Notes

2011 Hyundai Santa Fe GLS, 3.5 G, AWDSECTION Notes
WARNING: This page is about a different variant/trim than selected.
SOLENOID VALVE SPECIFICATIONS

Item Function Piece Specification
VFS 26/B T/Con 2 Control pressure: 9.81~500.14kpa (0.1~5.1kgf/cm2 , 1.42~72.54 psi)
Current value: 50~850mA
Low Type, 5.1Ξ©
Line pressure control 1 Control pressure: 500.14~9.81kpa (5.1~0.1kgf/cm2 , 72.54~1.42psi)
Current value: 50~850mA
High Type, 5.1Ξ©
35R
UD
OD
3 Control pressure: 500.14~9.81kpa (5.1~0.1kgf/cm2 , 72.54~1.42psi)
Current value: 50~850mA
High Type, 5.1Ξ©
On/Off SS-A
SS-B
2 Control pressure: 490.33kpa (5.0kgf/cm2 , 71.12psi)
10~11Ξ©