System Charging

2005 Hyundai Tiburon L4-2.0LSECTION System Charging
SYSTEM CHARGING

CAUTION
- Air conditioning refrigerant or lubricant vapor can Irritate your eyes, nose, or throat.
- Be careful when connecting service equipment.
- Do not breathe refrigerant or vapor.

If accidental system discharge occurs, ventilate work area before resuming service. Additional health and safety information may be obtained from the refrigerant and lubricant manufacturers.




1. Connect a R-134a refrigerant recover/recycling/charging station(A) to the high-pressure service port(B) and the low-pressure service port(C), as shown, following the equipment manufacture s instructions.
2. Add the same amount of new refrigerant oil to the system that was removed during recovery. Use only FD46XG (RAG) refrigerant oil
3. Charge the system with the specified amount of R-134a refrigerant. Do not overcharge the system; the compressor will be damaged.

Refrigerant capacity: 600 ± 25g