DTC P0498

2020 Honda HR-V LX, FWDSECTION DTC P0498

DTC P0498:  Evaporative Emission (EVAP) Canister Vent Shut Valve Circuit Low Voltage

General Description 

GHH434111Courtesy of HONDA, U.S.A., INC.

The evaporative emission (EVAP) canister vent shut valve is attached to the EVAP canister to control the venting of the EVAP canister to atmosphere. The EVAP canister vent shut valve is open (open to atmosphere) when the VSV signal is OFF. If the return signal is "OFF" when the powertrain control module (PCM) outputs the "ON" signal to the EVAP canister vent shut valve, the PCM detects a malfunction and stores a DTC.

Monitor Execution, Sequence, Duration, DTC Type 

Execution Continuous
Sequence None
Duration 5 seconds or more
DTC Type Two drive cycles, MIL on

Enable Conditions 

Condition Minimum Maximum
12 volt battery voltage [BATTERY] 10.0 V -
State of the engine Running

[ ]: HDS Parameter

Malfunction Threshold 

The return signal is "OFF" for at least 5 seconds when the PCM outputs the "ON" signal to the EVAP canister vent shut valve.

Possible Cause 

NOTE:  The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.

  • EVAP canister vent shut valve failure
  • EVAP canister vent shut valve VSV line open
  • EVAP canister vent shut valve VSV line short to ground
  • EVAP canister vent shut valve power supply line open
  • PCM internal circuit failure

Confirmation Procedure 

Operating Condition 

Start the engine.

With the HDS 

Select EVAP TEST in the INSPECTION MENU, and do the EVAP CVS ON in the SINGLE SOLENOID with the HDS.

Diagnosis Details 

Conditions for setting the DTC 

When a malfunction is detected during the first drive cycle, a Pending DTC is stored in the PCM memory. If the malfunction returns in the next (second) drive cycle, the MIL comes on and a Confirmed DTC and the freeze data are stored.

Conditions for clearing the DTC 

The MIL is cleared if the malfunction does not return in three consecutive trips in which the diagnostic runs. The MIL, the Pending DTC, the Confirmed DTC, and the freeze data can be cleared with the scan tool Clear command or by disconnecting the 12 volt battery.

RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.