2010 Honda Crosstour 2WD V6-3.5L
Recirculation Control Motor Test
2010 Honda Crosstour 2WD V6-3.5LSECTION Recirculation Control Motor Test
Recirculation Control Motor Test
Special Tools Required
- Backprobe Set 07SAZ-001000A (2)
NOTE: Before testing the motor, check for climate control DTCs Initial Inspection and Diagnostic Overview.
1. Disconnect the 7P connector from the recirculation control motor.
NOTICE
Incorrectly applying power and ground to the recirculation control motor will damage it. Follow the instructions carefully.
2. Connect battery power to terminal No. 7 of the recirculation control motor, and ground terminal No. 6; the recirculation control motor should run, and stop at Fresh. If it does not, reverse the connections; the recirculation control motor should run, and stop at Recirculate. When the recirculation control motor stops running, disconnect battery power immediately.
3. If the recirculation control motor did not run in step 2, remove it, then check the recirculation control linkage and door for smooth movement.
- If the linkage and door move smoothly, replace the recirculation control motor Recirculation Control Motor Replacement.
- If the linkage or door sticks or binds, repair them as needed.
- If the recirculation control motor runs smoothly, go to step 4.
4. Measure the resistance between terminals No. 1 and No. 3 of the recirculation control motor. It should be between 4.2 and 7.8 kOhms.
5. Reconnect the recirculation control motor 7P connector, then turn the ignition switch to ON (II).
6. Using the backprobe set (07SAZ-001000A), measure the voltage between terminals No. 2 and No. 3 of the 7P connector.
7. If either the resistance or the voltage readings are not as specified, replace the recirculation control motor Recirculation Control Motor Replacement.
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.