DTC B2005: Left Power Sliding Door Control Unit Lost Communication with MICU

2009 Honda Odyssey EX-LSECTION DTC B2005: Left Power Sliding Door Control Unit Lost Communication with MICU
NOTE: If you are troubleshooting multiple DTCs, be sure to follow the instructions in B-CAN System Diagnosis Test Mode A (see TROUBLESHOOTING - B-CAN SYSTEM DIAGNOSIS TEST MODE A ).
  1. Clear the DTCs with the HDS.
  2. Turn the ignition switch to LOCK (0), and then back to ON (II).
  3. Check for DTCs with the HDS.

    Is DTC B2005 indicated? 

    YES  - Go to step 4.

    NO  - Intermittent failure. The left power sliding door system is OK at this time. Check for loose or poor connections at the left power sliding door control unit connector, and at the MICU connector.

  4. Check for DTCs with the HDS.

    Are DTCs B1055, B1106, B1157, B1255, B1355, B1556, B1806, B1955, and/or B2055 also indicated? 

    YES  - Go to step  7.

    NO  - Go to step 5.

  5. Turn the ignition switch to LOCK (0).
  6. Do the left power sliding door control unit input test (see CONTROL UNIT INPUT TEST ).

    Is the input test OK? 

    YES  - Replace the left power sliding door control unit.

    NO  - Refer to the LEFT POWER SLIDING DOOR CONTROL UNIT INPUT TEST  and correct the cause.

  7. Turn the ignition switch to LOCK (0).
  8. Do the MICU input test (see MICU INPUT TEST ).

    Is the input test OK? 

    YES  - Faulty MICU, replace the driver's under-dash fuse/relay box.

    NO  - Refer to the MICU input test and correct the cause.

RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.