HOMESERVICE MANUALSGMC2009CANYON 4D PICKUP, 2.9 9REPAIR AND DIAGNOSISEXTERNAL PAGESDIFFERENT VARIANT/TRIMSECTION 10 (ENGINE CONTROL SYSTEM & FUEL SYSTEM - 3.7L - DTC P0013 TO DTC P0315)DTC P0107 OR P0108COMPONENT TESTING
2009 GMC Canyon 4D Pickup, 2.9 9
Component Testing
2009 GMC Canyon 4D Pickup, 2.9 9SECTION Component Testing
WARNING: This page is about a different variant/trim than selected.
IMPORTANT:
You must perform the circuit/system testing, in order to verify the integrity of the MAP sensor circuits, before proceeding with the component testing.
Erratic Signal Test
- Ignition OFF, remove the MAP sensor.
- Install a 3A fused jumper wire between the 5-volt reference circuit terminal 1 and the corresponding terminal of the MAP sensor.
- Install a jumper wire between the low reference circuit terminal 2 of the MAP sensor and ground.
- Install a jumper wire at terminal 3 of the MAP sensor.
- Connect a DMM between the jumper wire from terminal 3 of the MAP sensor and ground.
- Ignition ON, with the J 23738-AΒ
or J 35555Β
, slowly apply vacuum to the sensor while observing the voltage on the DMM. The voltage should vary between 0-5.2 volts without any spikes or dropouts.
- If the voltage reading is erratic, replace the MAP sensor.
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.