Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
SYS.OK|MANUAL.DBβ LIVE
HOMESERVICE MANUALSGMC1999FORWARD CONTROL 5.7 R, AUTOMATICREPAIR AND DIAGNOSISEXTERNAL PAGESDIFFERENT CARSECTION 66 (AUTOMATIC TRANSMISSION SERVICING)LUBRICATIONOIL COOLER FLUSHINGINITIAL FLUSH
1999 GMC Forward Control 5.7 R, Automatic
Initial Flush
1999 GMC Forward Control 5.7 R, AutomaticSECTION Initial Flush
WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2002 GMC Savana Special, 2002 GMC Savana Camper Special, 2002 GMC Savana, 2002 Chevrolet RV Cutaway, and 2002 Chevrolet Cutaway. However, it is still accessible from the selected car via links, so may be relevant.
- Turn the flusher water supply valve (1) to the ON position and allow water to flow through the oil cooler and pipes for 10 seconds to remove any remaining transmission fluid. See Fig 1 . If water does not flow through the oil cooler and pipes, the cause of the blockage must be diagnosed and the plugged component must be repaired or replaced. Continue with the cooler flushing and flow check procedure once the blockage is corrected.
- Turn the flusher water supply valve (1) to the OFF position and clip the discharge hose (5) onto an appropriate container with a lid, to avoid splashback. See Fig 2 . Turn flusher water supply valve (1) to the ON position and depress the trigger (8) to mix cooler flushing solution into the water flow. See Figure . Use the clip provided on the handle to hold the trigger (8) down. The discharge will foam vigorously when the solution is introduced into the water stream.
- Flush the oil cooler and pipes with water and solution for 2 minutes. During this flush, attach the shop air supply of 120 psi (825 kPa) to the flushing system feed air valve (2) located on the flusher for 3-5 seconds at the end of every 15-20 second interval to create a surging action.
- Release the trigger (8) and turn the flusher water supply valve (1) to the OFF position.
NOTE:
Flushing for approximately 2 minutes in each cooler line direction will result in a total of about 8-10 gallons of waste fluid. This mixture of water and flushing fluid is to be captured in an appropriate container for proper disposal.
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.