Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
SYS.OK|MANUAL.DB● LIVE
HOMESERVICE MANUALSFORD2021TRANSIT-350 HD BASE, VAN CARGO EXTENDED, 3.5L ENG VIN 8, AWDREPAIR AND DIAGNOSISEXTERNAL PAGESDIFFERENT CARSECTION 401 (GENERATOR AND REGULATOR)SPECIFICATIONSGENERAL SPECIFICATIONS
2021 Ford Transit-350 HD Base, Van Cargo Extended, 3.5L Eng VIN 8, AWD
General Specifications
2021 Ford Transit-350 HD Base, Van Cargo Extended, 3.5L Eng VIN 8, AWDSECTION General Specifications
WARNING: This page is about a different car, the 2020 Ford F-150. However, it is still accessible from the selected car via links, so may be relevant.
| Item | Specification |
|---|---|
| 2.7L EcoBoost, 3.3L Duratec and 3.5L EcoBoost without climate controlled seats or Alternating Current (AC) power outlet socket - 200 amp | |
| Generator amps at 80.6°F (27°C) | 130 amps at 675 rpm (min) to 200 amps at 2, 250 rpm (max) |
| Generator pulley ratio | 2.67:1 |
| Generator pulley replaceable | Yes |
| Generator pulley type | Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type | Electronic internal with generator |
| 2.7L EcoBoost, 3.3L Duratec and 3.5L EcoBoost with climate controlled seats or Alternating Current (AC) power outlet socket - 240 amp | |
| Generator amps at 80.6°F (27°C) | 130 amps at 675 rpm (min) to 240 amps at 2, 250 rpm (max) |
| Generator pulley ratio | 2.67:1 |
| Generator pulley replaceable | Yes |
| Generator pulley type | Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type | Electronic internal with generator |
| 3.0L Power Stroke Diesel - 250 amp | |
| Generator amps at 80.6°F (27°C) | 140 amps at 700 rpm (min) to 250 amps at 2, 300 rpm (max) |
| Generator pulley ratio | 2.67:1 |
| Generator pulley replaceable | Yes |
| Generator pulley type | Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type | Electronic internal with generator |
| 5.0L Ti-VCT without climate controlled seats, snowplow or Alternating Current (AC) power outlet socket - 200 amp | |
| Generator amps at 80.6°F (27°C) | 130 amps at 640 rpm (min) to 200 amps at 2, 135 rpm (max) |
| Generator pulley ratio | 2.81:1 |
| Generator pulley replaceable | No |
| Generator pulley type | Solid |
| Voltage regulator type | Electronic internal with generator |
| 5.0L Ti-VCT with climate controlled seats, snowplow or Alternating Current (AC) power outlet socket - 240 amp | |
| Generator amps at 80.6°F (27°C) | 130 amps at 675 rpm (min) to 240 amps at 2, 250 rpm (max) |
| Generator pulley ratio | 2.81:1 |
| Generator pulley replaceable | No |
| Generator pulley type | Solid |
| Voltage regulator type | Electronic internal with generator |
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.