General Specifications Primary Generator
2021 Ford Edge SE, 4WDSECTION General Specifications Primary Generator
WARNING: This page is about a different car, the 2021 Ford F-150. However, it is still accessible from the selected car via links, so may be relevant.
| Item | Specification |
|---|---|
| 2.7L EcoBoost, 3.3L Duratec and 3.5L EcoBoost without climate controlled seats or Alternating Current (AC) power outlet socket - 200 amp | |
| Generator amps at 80.6°F (27°C) | 107 amps at 625 rpm (min) to 201 amps at 2, 500 rpm (max) |
| Generator pulley ratio | 2.67:1 |
| Generator pulley replaceable | Yes |
| Generator pulley type | Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type | Electronic internal with generator |
| 2.7L EcoBoost, 3.3L Duratec and 3.5L EcoBoost with climate controlled seats or Alternating Current (AC) power outlet socket - 240 amp | |
| Generator amps at 80.6°F (27°C) | 137 amps at 625 rpm (min) to 243 amps at 2, 500 rpm (max) |
| Generator pulley ratio | 2.67:1 |
| Generator pulley replaceable | Yes |
| Generator pulley type | Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type | Electronic internal with generator |
| 3.0L Power Stroke Diesel - 250 amp | |
| Generator amps at 80.6°F (27°C) | 116 amps at 625 rpm (min) to 254 amps at 2, 500 rpm (max) |
| Generator pulley ratio | 2.66:1 |
| Generator pulley replaceable | Yes |
| Generator pulley type | Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type | Electronic internal with generator |
| 5.0L Ti-VCT without climate controlled seats, snowplow or Alternating Current (AC) power outlet socket - 200 amp | |
| Generator amps at 80.6°F (27°C) | 115 amps at 625 rpm (min) to 202 amps at 2, 500 rpm (max) |
| Generator pulley ratio | 2.81:1 |
| Generator pulley replaceable | Yes |
| Generator pulley type | Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type | Electronic internal with generator |
| 5.0L Ti-VCT with climate controlled seats, snowplow or Alternating Current (AC) power outlet socket - 240 amp | |
| Generator amps at 80.6°F (27°C) | 149 amps at 625 rpm (min) to 244 amps at 2, 500 rpm (max) |
| Generator pulley ratio | 2.81:1 |
| Generator pulley replaceable | Yes |
| Generator pulley type | Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type | Electronic internal with generator |
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.