Exterior Trim And Ornamentation DTCS

2018 Ford F-150 XLT, 4D Pickup Extra Cab, 3.5L Eng VIN G, RWDSECTION Exterior Trim And Ornamentation DTCS
DTC INDEX

DTC Description Action
C1002:77 Left Power Running Board Stow: Commanded Position Not Reachable Inspect for debris or corrosion at pivot points that may cause a slow moving PRB. CLEAN or repair as necessary. TEST the system for normal operation. If the concern returns, REPLACE the LH PRB motor. REFER to: Power Running Board (PRB) Motor .
C1003:77 Right Power Running Board Stow: Commanded Position Not Reachable Inspect for debris or corrosion at pivot points that may cause a slow moving PRB. CLEAN or repair as necessary. TEST the system for normal operation. If the concern returns, REPLACE the RH PRB motor. REFER to: Power Running Board (PRB) Motor .
C1004:77 Right Power Running Board Deploy: Commanded Position Not Reachable Inspect for debris or corrosion at pivot points that may cause a slow moving PRB. CLEAN or repair as necessary. TEST the system for normal operation. If the concern returns, REPLACE the RH PRB motor. REFER to: Power Running Board (PRB) Motor .
C1005:77 Left Power Running Board Deploy: Commanded Position Not Reachable Inspect for debris or corrosion at pivot points that may cause a slow moving PRB. CLEAN or repair as necessary. TEST the system for normal operation. If the concern returns, REPLACE the LH PRB motor. REFER to: Power Running Board (PRB) Motor .
C1006:11 Left Power Running Board Motor: Circuit Short To Ground GO to Pinpoint Test D
C1006:12 Left Power Running Board Motor: Circuit Short To Battery GO to Pinpoint Test D
C1006:13 Left Power Running Board Motor: Circuit Open GO to Pinpoint Test D
C1006:19 Left Power Running Board Motor: Circuit Current Above Threshold GO to Pinpoint Test D
C1007:11 Right Power Running Board Motor: Circuit Short To Ground GO to Pinpoint Test E
C1007:12 Right Power Running Board Motor: Circuit Short To Battery GO to Pinpoint Test E
C1007:13 Right Power Running Board Motor: Circuit Open GO to Pinpoint Test E
C1007:19 Right Power Running Board Motor: Circuit Current Above Threshold GO to Pinpoint Test E
C1008:3A Left Power Running Board Position/Motion Sensor: Signal Has Too Many Pulses Internal PRB motor damage. INSTALL a new LH PRB motor. REFER to: Power Running Board (PRB) Motor .
C1008:93 Left Power Running Board Position/Motion Sensor: No Operation GO to Pinpoint Test F
C1009:3A Right Power Running Board Position/Motion Sensor: Signal Has Too Many Pulses Internal PRB motor damage. INSTALL a new RH PRB motor. REFER to: Power Running Board (PRB) Motor .
C1009:93 Right Power Running Board Position/Motion Sensor: No Operation GO to Pinpoint Test F
C1B14:11 Sensor Supply Voltage A: Circuit Short To Ground GO to Pinpoint Test F
C1B14:12 Sensor Supply Voltage A: Circuit Short To Battery GO to Pinpoint Test F
U0146:00 Lost Communication with Gateway "A": No Sub Type Information GO to Pinpoint Test G
U3000:00 Control Module: No Sub Type Information CLEAR the Diagnostic Trouble Codes (DTCs). CARRY OUT the RBM self-test. RETRIEVE and RECORD all Diagnostic Trouble Codes (DTCs).
If the DTC returns, INSTALL a new RBM. REFER to: Running Board Control Module (RBM) .
U3000:41 Control Module: General Checksum Failure CLEAR the Diagnostic Trouble Codes (DTCs). CARRY OUT the RBM self-test. RETRIEVE and RECORD all Diagnostic Trouble Codes (DTCs).
If the DTC returns, INSTALL a new RBM. REFER to: Running Board Control Module (RBM) .
U3000:49 Control Module: Internal Electronic Failure CLEAR the Diagnostic Trouble Codes (DTCs). CARRY OUT the RBM self-test. RETRIEVE and RECORD all Diagnostic Trouble Codes (DTCs).
If the DTC returns, INSTALL a new RBM. REFER to: Running Board Control Module (RBM) .
U3000:4B Control Module: Over Temperature CLEAR the Diagnostic Trouble Codes (DTCs). CARRY OUT the RBM self-test. RETRIEVE and RECORD all Diagnostic Trouble Codes (DTCs).
If the DTC returns, INSTALL a new RBM. REFER to: Running Board Control Module (RBM) .
U3003:16 Control Module: Circuit Voltage Below Threshold GO to Pinpoint Test H
U3003:17 Control Module: Circuit Voltage Above Threshold GO to Pinpoint Test I
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.