DTC Chart
2014 Ford Mustang GT, 2D Coupe, Automatic TransSECTION DTC Chart
NOTE:
Some modules on this vehicle utilize a 5-character DTC followed by a 2-character failure-type code. The failure-type code provides information about specific fault conditions such as opens, or shorts to ground. Continuous Memory DTCs have an additional 2-character DTC status code suffix to assist in determining DTC history.
| DTC | Description | Source | Action |
|---|---|---|---|
| B2477 | Module Configuration Failure |
|
CARRY OUT PMI . REFER to PROGRAMMABLE MODULE INSTALLATION (PMI) . |
| P0315 | Crankshaft Position System Variation Not Learned |
|
Using the scan tool, CARRY OUT the Misfire Monitor Neutral Profile Correction procedure, following the on-screen instructions. |
| P0602 | Powertrain Control Module Programming Error |
|
CARRY OUT PMI . REFER to PROGRAMMABLE MODULE INSTALLATION (PMI) . |
| P0603 | EEPROM Malfunction: Not Configured |
|
CARRY OUT PMI . REFER to PROGRAMMABLE MODULE INSTALLATION (PMI) . |
| P0605 | Internal Control Module Read Only Memory (ROM ) Error |
|
CARRY OUT PMI . REFER to PROGRAMMABLE MODULE INSTALLATION (PMI) . |
| P1639 | Vehicle ID Block Corrupted, Not Programmed |
|
CARRY OUT PMI . REFER to PROGRAMMABLE MODULE INSTALLATION (PMI) . |
| U0300 | Internal Control Module Software Incompatibility |
|
CARRY OUT PMI . REFER to PROGRAMMABLE MODULE INSTALLATION (PMI) . |
| U201A:51 | Control Module Main Calibration Data: Not Programmed |
|
CARRY OUT PMI . REFER to PROGRAMMABLE MODULE INSTALLATION (PMI) . |
| U2050 | No Application Present |
|
CARRY OUT PMI . REFER to PROGRAMMABLE MODULE INSTALLATION (PMI) . |
| U2051 | One or More Calibration Files Missing/Corrupt |
|
CARRY OUT PMI . REFER to PROGRAMMABLE MODULE INSTALLATION (PMI) . |
| U2100:00 | Initial Configuration Not Complete: No Sub Type Information |
|
CARRY OUT PMI . REFER to PROGRAMMABLE MODULE INSTALLATION (PMI) . |
| U2100:00 | Initial Configuration Not Complete: No Sub Type Information |
|
CARRY OUT APIM programming. REFER to INFORMATION AND ENTERTAINMENT SYSTEMS . |
| U2100:55 | Initial Configuration Not Complete: Not Configured |
|
CARRY OUT PMI . REFER to PROGRAMMABLE MODULE INSTALLATION (PMI) . |
| U2101:00 | Control Module Configuration Incompatible: No Sub Type Information |
|
CARRY OUT APIM programming. REFER to INFORMATION AND ENTERTAINMENT SYSTEMS . |
| U2101:00 | Control Module Configuration Incompatible: No Sub Type Information |
|
CARRY OUT PMI . REFER to PROGRAMMABLE MODULE INSTALLATION (PMI) . |
| U2101:56 | Control Module Configuration Incompatible: Invalid/Incompatible Configuration |
|
CARRY OUT PMI . REFER to PROGRAMMABLE MODULE INSTALLATION (PMI) . |
| U3002:62 | Vehicle Identification Number: Signal Compare Failure |
|
CARRY OUT PMI . REFER to PROGRAMMABLE MODULE INSTALLATION (PMI) . |
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.