3.7L 4V Mks/Mkt

2009 Ford Fusion SEL, 3.0 1, FWDSECTION 3.7L 4V Mks/Mkt
WARNING: This page does not describe the selected car, but rather 29 other vehicles, including the 2011 Mercury Milan, 2011 Mercury Mariner, 2011 Lincoln Navigator L, 2011 Lincoln Navigator, and 2011 Lincoln MKZ. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: 190 Pin PCM Connectors - 3.7L 4V MKS/MKT
G06054072Courtesy of FORD MOTOR CO.

Typical Diagnostic Reference Values 

SENSORS - 3.7L 4V MKS/MKT

Sensors/Inputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
PSP B17 LOW HIGH LOW LOW HIGH/LOW
GENMON B23 0 42.19 33.59 24.22 %
APP1 B25 4.07 4.07 3.86 3.66 VOLTS
APP2 B26 1.42 1.42 1.57 1.73 VOLTS
APP3 B27 0.88 0.88 1.08 1.22 VOLTS
FPM B30 0 0 0 0 %
ACP_PRESS B37 1.26/93.97 1.47/119.97 1.06/69.99 1.04/65.99 VOLTS/PSI
MAF B41 0.01 0.56 1.34 1.56 VOLTS
IAT B43 1.94/45 (113) 2.01/43 (109.4) 3.65/7 (44.6) 3.99/-4 (24.8) VOLTS/DEG C (DEG F)
FTP B44 2.62/0.61 2.43/0.61 2.62/0.61 2.32/0.61 VOLTS/PSI
BPA B47 OFF OFF OFF OFF ON/OFF
O2S11_CUR E18 (I) switching switching switching mA/uA
O2S21_CUR E20 (I) switching switching switching mA/uA
O2S12 E23 (I) (D) (D) (D) VOLTS
O2S22 E24 (I) (D) (D) (D) VOLTS
CHT E41 0.56/92 (197.6) 0.54/93 (199.4) 3.68/91 (195.8) 3.73/89 (192.2) VOLTS/DEG C (DEG F)
TP2 E60 1.27/25.49 0.81/16.08 0.96/19.22 1.35/26.67 VOLTS/%
TP1 E61 4.09/18.04 4.32/13.33 4.24/14.9 4.04/18.82 VOLTS/%
TSS T15 0 585.8 1136 1612 RPM
ACCS PID OFF OFF OFF OFF ON/OFF
APP PID 0 0 7 14 %
B+ PID 12.19 13.94 14.0 13.94 VOLTS
BARO PID 14.3/156.2 14.3/156.2 14.3/156.2 14.3/156.2 PSI/Hz
BOO PID OFF OFF OFF OFF ON/OFF
CPP/PNP PID NEUTRAL NEUTRAL DRIVE DRIVE NEUTRAL/DRIVE
DECHOKE PID YES NO NO NO YES/NO
EONV_RDY PID NOT READY NOT READY NOT READY NOT READY READY/NOT READY
EQ_RAT11 PID 0 1.03 1.02 1.0 RATIO
EQ_RAT21 PID 0 1.02 0.98 0.97 RATIO
ETC_ACT PID 7.62 1.20 7.81 9.54 DEG
ETC_DSD PID 7.62 1.33 7.79 9.58 DEG
ETC_TRIM PID -0.05 (J) -0.24 (J) -0.24 (J) -0.24 (J) DEG
FCIL PID OFF OFF OFF OFF ON/OFF
FLI PID 40.7 (H) 56.42 (H) 54.81 (H) 51.34 (H) %
GEAR PID 1 1 5 6 GEAR
INJPWR_M PID 12.31 13.94 13.94 13.99 VOLTS
LOAD PID 51.3(I) 16.97 27.92 32.57 %
MIL_DIS PID 0 0 0 0 Miles
MISFIRE PID NO NO NO NO YES/NO
MP_LRN PID YES NO YES YES YES/NO
NM PID 0 0 0 0 COUNT
O2S11_IMPED PID 4.95 1.01 1.03 0.99 VOLTS
O2S21_IMPED PID 4.95 1.0 1.05 1.02 VOLTS
OSS PID 0 0 1224 2163 RPM
OSS_SRC PID 0 0 1220 2159 RPM
RPM PID 0 616.5 1277 1605 RPM
STRT_RLY PID DISABLED DISABLED DISABLED DISABLED ENABLED/DISABLED
SYNC PID NO YES YES YES YES/NO
TCIL PID OFF OFF OFF OFF ON/OFF
TFT PID 85 (185) 49 (120.2) 74 (165.2) 76 (168.8) DEG C (DEG F)
TFTV PID 0.7 1.79 0.95 0.89 VOLTS
TORQUE PID 155 6.67 36.07 108.2 Nm
TR PID PARK PARK OVERDRIVE OVERDRIVE POSITION
TR2 PID OPEN OPEN CLOSED CLOSED OPEN/CLOSED
TSS/ISS PID 0 585.3 1135 1614 RPM
TSS_SRC PID 0 585.8 1136 1614 RPM
VSS PID 0 0 48 km/h (30 MPH) 89 km/h (55 MPH) km/h/MPH
ACTUATORS - 3.7L 4V MKS/MKT

Actuators/Outputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
EVMV B50 0/OFF 778/VARYING 935/VARYING 648/ON mA/ON/OFFVARYING
FP B62 OFF ON ON ON ON/OFF
HTR12 E1 OFF ON ON ON ON/OFF
HTRCM12 E1 613 652 652 652 mA
HTR22 E2 OFF ON ON ON ON/OFF
HTRCM22 E2 648 676 676 676 mA
VCTADV E67 0 -0.06 -12.38 -39 DEG
VCTADV2 E68 0 0.12 -34.13 -37.13 DEG
O2S11_HTR E69 0 36.8 36.08 35.32 %
HTR11 E69 OFF ON ON ON ON/OFF
HTRCM11 E69 1.4 1.43 1.43 1.43 Amps
O2S21_HTR E70 0 36.09 35.35 34.89 %
HTR21 E70 OFF ON ON ON ON/OFF
HTRCM21 E70 1.45 1.46 1.46 1.46 Amps
CAT_EVAL PID YES NO NO YES YES/NO
CLRDIST PID 54.04 1.86 2.48 11.18 MILES
EGR_EVAL PID YES YES YES YES YES/NO
EVAP020C PID NO NO NO NO YES/NO
EVAP020D PID ALLOW ALLOW ALLOW ALLOW ALLOW/DISALLOW
EVAP020R PID NOT READY NOT READY NOT READY NOT READY READY/NOT READY
EVAPCV PID 0/OFF 0/OFF 0/OFF 0/OFF %/ON/OFF
EVAPSOAK PID NO NO NO NO YES/NO
EVAPSTA PID NOT RUNNING NOT RUNNING NOT RUNNING NOT RUNNING STATUS
EVAP_EVAL PID NO NO NO NO YES/NO
FANDC PID 7.99 10 7.99 7.99 %
FANVAR PID 0 0 0 0 %
FTP_H20 PID -0.03 -1.3 0 -2.13 in-H2 O
FUELSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN/CLOSED LOOP
IGN_R/S PID ON ON ON ON ON/OFF
LONGFT1 PID 2.73(I) -20 TO +20 -20 TO +20 -20 TO +20 %
LONGFT2 PID 4.29(I) -20 TO +20 -20 TO +20 -20 TO +20 %
MIL PID OFF OFF OFF OFF ON/OFF
O2S_EVAL PID YES NO NO YES YES/NO
O2SHTR_EVAL PID YES NO NO YES YES/NO
RPMDSD PID 800 608 608 608 RPM
SHRTFT1 PID 0(I) -10 TO +10 -10 TO +10 -10 TO +10 %
SHRTFT2 PID 0(I) -10 TO +10 -10 TO +10 -10 TO +10 %
SPARKADV PID 10 13.25 30 38.5 DEG
TRIP_CNT PID 0 0 0 0 COUNT
VCTADVERR PID 0 0.06 -0.31 -1.87 DEG
VCTADVERR2 PID 0 0.12 0 -1.62 DEG
VCTDC PID 0 0 47.32 48.56 %
VCTDC2 PID 0 0 47.93 49.45 %
VCTSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN/CLOSED LOOP
OTHERS - 3.7L 4V MKS/MKT

Other PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VPWR B51/52/53 12 13-14 13-14 13-14 VOLTS
VREF B64 5 5 5 5 VOLTS
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.