2008 Ford Explorer 2WD V8-4.6LFACTORY OEM SERVICE PROCEDURE

Fuel Tank Pressure Sensor: Service and Repair

FUEL TANK PRESSURE SENSOR


Factory service manual diagram





Removal and Installation

WARNING:
- When working on or near the evaporative emission (EVAP) system, disconnect the battery ground cable from the battery. The EVAP system contains fuel vapor and condensed fuel vapor, so an electrical spark may cause a fire or explosion. Failure to follow this instruction may result in serious personal injury.
- Do not smoke, carry lighted tobacco or have an open flame of any type when working on or near any fuel-related component. Highly flammable mixtures are always present and may be ignited. Failure to follow these instructions may result in serious personal injury.


1. Remove the evaporative emission (EVAP) canister.
2. Remove the fuel tank shield from the fuel tank.
3. Disconnect the fuel tank pressure (FTP) sensor electrical connector.
4. Disconnect the 3 FTP sensor and tube assembly quick connect couplings from the fuel pump module and the vapor vent valves.
5. Remove the FTP sensor and tube assembly.
6. To install, reverse the removal procedure.
7. Leak test the EVAP system.
8. Carry out the evaporative emission repair verification drive cycle.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.