Diagnostic Trouble Code (DTC) Tables

2007 Ford Fusion SEL, 2.3 Z, StandardSECTION Diagnostic Trouble Code (DTC) Tables
WARNING: This page is about a different car, the 2006 Mercury Montego and 2006 Ford Five Hundred. However, it is still accessible from the selected car via links, so may be relevant.
DIAGNOSTIC TROUBLE CODE TABLE

Five Digit DTC Component Description Condition Symptom Action
P0562 Battery System voltage low PCM detected a voltage level below 9 volts No engagements, no adaptive or self-learning strategy. REFER to the INTRODUCTION - GASOLINE article.
P0563 Battery System voltage high PCM detected a voltage level above 18 volts No adaptive or self-learning strategy. Refer to the INTRODUCTION - GASOLINE article.
P0601 PCM PCM ROM error PCM detected an internal software concern with ROM No engagements, no adaptive or self-learning strategy. REFER to the INTRODUCTION - GASOLINE article.
P0603 PCM PCM KAM error PCM detected an internal software concern with KAM No engagements, no adaptive or self-learning strategy. REFER to the INTRODUCTION - GASOLINE article.
P0604 PCM PCM RAM error PCM detected an internal software concern with RAM No engagements, no adaptive or self-learning strategy. REFER to the INTRODUCTION - GASOLINE article.
P0706 TR sensor TR sensor range or performance error TR sensor signal is out of normal range TR sensor indicates a stuck position (D-3rd gear), no adaptive or self learning strategy. Install a new TCM.
P0707 TR sensor TR sensor circuit low input TR sensor signal is below threshold of 0.127 volts, sensor/circuit electrical malfunction TR sensor indicates a stuck position (D-3rd gear), no adaptive or self learning strategy. Install a new TCM.
P0708 TR sensor TR sensor circuit high input TR sensor signal is above threshold of 4.87 volts, sensor/circuit electrical malfunction TR sensor indicates a stuck position (D-3rd gear), no adaptive or self learning strategy. Install a new TCM.
P0711 TFT sensor No change in TFT during operation PCM has detected no TFT change during operation. TFT value stuck at some normal reading TFT indicates 80°C (176°F) at all times, no self learning strategy, no TCC engagement. GO to PINPOINT TEST B .
P0712 TFT sensor 200°C (329°F) indicated, TFT sensor circuit grounded Voltage drop across TFT sensor exceeds scale set for temperature -43°C (-45°F) TFT indicates 80°C (176°F) at all times, no self learning strategy, no TCC engagement. GO to PINPOINT TEST B .
P0713 TFT sensor -43°C (-45°F) indicated, TFT sensor circuit grounded Voltage drop across TFT sensor exceeds scale set for temperature -43°C (-45°F) TFT indicates 80°C (176°F) at all times, no self learning strategy, no TCC engagement. GO to PINPOINT TEST B .
P0716 TSS sensor TSS range out of performance, insufficient input from TSS PCM has detected a loss or noisy TSS signal during operation No TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST D .
P0717 TSS sensor No TSS signal PCM has not detected a TSS signal. No TSS signal when OSS signal present No TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST D .
P0721 OSS sensor OSS range out of performance, insufficient input from OSS PCM has detected a loss or noisy OSS signal during operation No adaptive or self learning strategy. GO to PINPOINT TEST C .
P0722 OSS sensor No OSS signal PCM has detected no TSS signal No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST C .
P0729 Transaxle 6th gear ratio No 6th gear ratio detected by TCM No 6th gear, no TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0730 Clutch control solenoids or internal parts Gear ratio error PCM has detected a gear ratio error No self learning strategy. GO to PINPOINT TEST A .
P0731 Solenoid or internal parts 1st gear ratio No 1st gear ratio detected by TCM No 1st gear, no TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0732 Solenoid or internal parts 2nd gear ratio No 2nd gear ratio detected by TCM No 2nd gear, no TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0733 Solenoid or internal parts 3rd gear ratio No 3rd gear ratio detected by TCM No 3rd gear, no TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0734 Solenoid or internal parts 4th gear ratio No 4th gear ratio detected by TCM No 4th gear, no TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0735 Solenoid or internal parts 5th gear ratio No 5th gear ratio detected by TCM No 5th gear, no TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0736 Transaxle Reverse gear ratio No reverse gear ratio detected by TCM No reverse gear, no self learning strategy. GO to PINPOINT TEST A .
P0780 Solenoid or valve internal to transaxle Universal shifting (stuck valve) Valve stuck Increase rpm during shifts. Slipping or erratic shifting. Go to MAIN CONTROL VALVE BODY .
P0817 TCM/PCM starter circuit Starter disable circuit open or shorted to power/ground TCM detected a failure in the starter lock circuit, failed ON or OFF Ignition switch is ON, TCM and PCM communication is normal. No voltage is detected on the start lock circuit for more than 0.1 second or a continuous 12-volt output is detected for more than 0.1 second. Conditions present 2 times to set DTC DTC is set. Warning lamp is illuminated. GO to PINPOINT TEST E .
P0961 PCA PCA circuit or solenoid failure PCA circuit or solenoid (SLT) failed during operation. Incorrect commanded current detected by TCM No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0962 PCA PCA solenoid signal or grounded circuits either short or open, solenoid circuit failure Voltage through PCA solenoid (SLT) is checked. An error will be noted if tolerance is exceeded No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0963 PCA PCA solenoid short to power circuit failure Voltage through PCA solenoid (SLT) is checked. An error will be noted if tolerance is exceeded No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0973 SSA SSA solenoid or circuit shorted to ground Voltage through SSA solenoid (S1) circuit is checked. An error will be noted if tolerance is exceeded. Short to ground failure detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0974 SSA SSA solenoid or circuit shorted to power or open Voltage through SSA solenoid (S1) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0976 SSB SSB solenoid or circuit shorted to ground Voltage through SSB solenoid (S2) circuit is checked. An error will be noted if tolerance is exceeded. Short to ground failure detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0977 SSB SSB solenoid or circuit shorted to power or open Voltage through SSB solenoid (S2) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0978 SSC SSC circuit or solenoid failure SSC circuit or solenoid (SLC1) failed during operation. Incorrect commanded current detected by TCM No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0979 SSC SSC solenoid signal or grounded circuits either shorted or open, solenoid circuit failure Voltage through SSC solenoid (SLC1) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0980 SSC SSC solenoid or circuit shorted to power Voltage through SSC solenoid (SLC1) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0981 SSD SSD circuit or solenoid failure SSD circuit or solenoid (SLC2) failed during operation. Incorrect commanded current detected by TCM No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0982 SSD SSD solenoid signal or grounded circuits either shorted or open, solenoid circuit failure Voltage through SSD solenoid (SLC2) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0983 SSD SSD solenoid or circuit shorted to power Voltage through SSD solenoid (SLC2) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0984 SSE SSE circuit or solenoid failure SSE circuit or solenoid (SLC3) failed during operation. Incorrect commanded current detected by TCM No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0985 SSE SSE solenoid signal or grounded circuits either shorted or open, solenoid circuit failure Voltage through SSE solenoid (SLC3) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0986 SSE SSE solenoid or circuit shorted to power Voltage through SSE solenoid (SLC3) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0997 SSF SSF circuit or solenoid failure SSF circuit or solenoid (SLB1) failed during operation. Incorrect commanded current detected by TCM No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0998 SSF SSF solenoid signal or grounded circuits either shorted or open, solenoid circuit failure Voltage through SSF solenoid (SLB1) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P0999 SSF SSF solenoid or circuit shorted to power Voltage through SSF solenoid (SLB1) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P1576 APP sensor APP sensor input error Sets code in the TCM. Will put the transaxle in a fail safe mode. No adaptive or self learning strategy. CLEAR the code in the TCM. REFER to the INTRODUCTION - GASOLINE article for APP diagnostic.
P1657 TCM TCM communication link error CAN link error detected by PCM No engagements, no adaptive or self learning strategy. Limited fuel and spark. Install a new transmission control module (TCM).
P1700 Transaxle Drive engagement error TCM detected neutral in the DRIVE position No engagements, no adaptive or self learning strategy. REFER to DIAGNOSIS BY SYMPTOM .
P1701 Transaxle Reverse engagement error TCM detected neutral in the REVERSE position No self learning strategy. REFER to DIAGNOSIS BY SYMPTOM .
P1719 PCM/TCM CAN Engine torque signal error Engine torque calculation signal received from PCM is inaccurate based on actual vehicle operating conditions Engine concerns may be present that cause the transaxle not to operate correctly. DIAGNOSE and REPAIR all engine concerns. CLEAR DTCs, road test the vehicle and rerun OBD.
P1919 ECT ECT sensor signal error PCM/TCM have detected an error in the CAN ECT information No TCC engagements, ECT set to 80°C (176°F). REFER to the INTRODUCTION - GASOLINE article.
P1920 Engine RPM Engine RPM sensor signal error PCM/TCM have detected an error in the CAN engine RPM information No adaptive or self learning strategy. Limited fuel and spark. REFER to the INTRODUCTION - GASOLINE article.
P2544 PCM Torque management request input signal A Data received from the PCM or engine components are not correct for the vehicle operating conditions. Incorrect engine torque calculation may result Transmission may enable limp-home strategies or increase pressures. Engine components and PCM may or may not set additional DTCs. P2544, fuel monitor error, ECT sensor failure and MAF sensor failures may be present. MIL may illuminate. REFER to the INTRODUCTION - GASOLINE article.
P2757 TCC solenoid TCC solenoid circuit failure, stuck OFF TCC solenoid (SLU) circuit fails to provide voltage drop across solenoid. Circuit open, shorted or PCM driver failure during on-board diagnostic No TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P2758 TCC solenoid TCC solenoid circuit failure, stuck ON TCC solenoid (SLU) circuit fails to provide voltage drop across solenoid. Circuit open, shorted or PCM driver failure during on-board diagnostics No TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P2762 TCC solenoid TCC circuit or solenoid failure TCC circuit or solenoid (SLU) failed during operation. Incorrect commanded current detected by TCM No engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P2763 TCC solenoid TCC circuit shorted to power TCC solenoid (SLU) circuit fails to provide voltage drop across solenoid. Circuit shorted to power No TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
P2764 TCC solenoid TCC solenoid signal or grounded circuits either short or open solenoid circuit failure TCC solenoid (SLU) circuit fails to provide voltage drop across solenoid No TCC engagements, no adaptive or self learning strategy. GO to PINPOINT TEST A .
U0073 TCM CAN TCM communication link error CAN link error detected by PCM No engagements, no adaptive or self learning strategy. REFER to the INTRODUCTION - GASOLINE article.
U0100 TCM CAN TCM communication link error CAN link error detected by PCM No engagements, no adaptive or self learning strategy.
NOTE: A module cannot communicate with other modules on the communication network while being reprogrammed. Clear any network communication DTCs which may have been set in other modules during reprogramming. CHECK CAN harness between TCM and other modules. REPAIR all other DTCs present first. For diagnostic information, REFER to the INTRODUCTION - GASOLINE article and REFER to MODULE COMMUNICATIONS NETWORK .
U0101 TCM/PCM TCM communication error PCM lost communication with the TCM
  • Engine driveability concerns.
  • Will turn on MIL and driver warning lamp.
NOTE: A module cannot communicate with other modules on the communication network while being reprogrammed. Clear any network communication DTCs which may have been set in other modules during reprogramming. CHECK CAN harness between TCM and other modules. REPAIR all other DTCs present first. For diagnostic information, REFER to the INTRODUCTION - GASOLINE article and REFER to MODULE COMMUNICATIONS NETWORK .
U0121 ABS system TCM communication link error PCM/TCM have detected an error in the CAN wheel RPM information from the ABS system No engagements, no adaptive or self learning strategy. REFER to VEHICLE DYNAMIC SYSTEMS .
U0401 PCM/TCM Invalid data received from the PCM or engine components Data received from the PCM or engine components is not correct for the vehicle operating conditions Transmission may enable limp-home strategies or increase pressures. Engine components and PCM may or may not set additional DTCs. P2544, fuel monitor error, ECT sensor failure and MAF sensor failures may be present. MIL may illuminate. REFER to the INTRODUCTION - GASOLINE article.
U0415 Wheel speed sensor TCM communication link error PCM/TCM have detected an error in the CAN wheel RPM information from the ABS system No adaptive or self learning strategy. REFER to VEHICLE DYNAMIC SYSTEMS .
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.