4.0L Explorer/Mountaineer

2007 Ford Escape Base, 2.3 Z, FWD, AutomaticSECTION 4.0L Explorer/Mountaineer
WARNING: This page does not describe the selected car, but rather 31 other vehicles, including the 2006 Mercury Mountaineer, 2006 Mercury Monterey, 2006 Mercury Montego, 2006 Mercury Milan, and 2006 Mercury Mariner. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: 170 Pin PCM Harness Connector
G03877989Courtesy of FORD MOTOR CO.
SENSORS/INPUTS - 4.0L EXPLORER/MOUNTAINEER

Sensors/Inputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
FTP V/FTP B3 2.6/0 2.6/0 2.6/0 2.6/0 DCV/IN-H2O
APP1 B5 4.0 4.0 3.4-4.0 2.9-4.0 DCV
BPP B8 0.1/OFF VBAT/ON (E) 0.1/OFF 0.1/OFF DCV/OFF-ON
BPS B9 VBAT/OFF 0.1/ON (E) VBAT/OFF VBAT/OFF DCV/OFF-ON
ACCS B15 VBAT/OFF VBAT/ON (A) VBAT/OFF VBAT/OFF DCV/ON-OFF
ACDS B16 0.1/ENABLE 0.1/ENABLE 0.1/ENABLE 0.1/ENABLE DCV/ENABLE DISABLED
APP2 B17 1.4 1.5 1.5-1.9 1.5-2.4 DCV
ACP B18 VBAT/OPEN VBAT/OPEN VBAT/OPEN VBAT/OPEN DCV/OPENCLOSED
FPM B21 0.1 0-VBAT 0-VBAT 0-VBAT DCV
GENLI B22 0 30 27 23 %
PSPS B27 0.5 3.75 (I) 0.5 0.5 DCV
APP3 B28 0.9 0.9 0.9-1.3 0.9-1.8 DCV
TCS B29 0.1/Not Depressed VBAT/Depressed (G) 0.1/Not Depressed 0.1/Not Depressed DCV/Depressed- Not Depressed
FEPS B44 0.1 0.1 0.1 0.1 DCV
ECT E18 0.4-1/200-160 0.4-1/200-160 0.4-1/200-160 0.4-1/200-160 DCV/DEG
FRT (K) E19 0.5-3/210-110 0.5-3/210-110 0.5-3/210-110 0.5-3/210-110 DCV/DEG
DPFEGR E21 0.25-1.30 0.25-1.30 0.25-4.65 0.25-4.65 DCV
IAT (K) E22 1.7-3.5/120-50 1.7-3.5/120-50 1.7-3.5/120-50 1.7-3.5/120-50 DCV/DEG
FANSS E24 0 300-500 300-550 300-500 RPM
MAF V E25 0 0.7-0.9 1.2-1.8 1.6-2.1 DCV
HO2S11 E28 (L) switching (C) switching (C) switching (C) DCV
HO2S21 E29 (L) switching (C) switching (C) switching (C) DCV
FRP V/FRP E32 3.4/55 2.8/40 2.8/40 2.8/38 DCV/PSI
CMP E45 0 5-6 11-12 14-16 Hz
CKP E47 0 380-410 800-860 980-1030 Hz
KS1 E49 8.19k 132 127 121 DCV
TP2 PS E60 1.2 0.7 1.1 1.4 DCV
TP1 NS E61 4.1 4.4 4.2 4.0 DCV
MAP E62 4.2/99 1-1.4/30 1.8-2.6/25 1.9-2.3/25 DCV/kPa
OSS T3 0 0 460-530/1250-1330 885-1000/2100-2400 Hz/RPM
HCDS T4 0 0 700 1180 Hz
TSS T15 0 320-360/630-670 500-713/1100-1310 845-985/1700-1800 Hz/RPM
TR 1 T16 0 0 VBAT VBAT DCV
TR 2 T17 0 0 VBAT VBAT DCV
HO2S12 T24 (L) (D) (D) (D) DCV
HO2S22 T25 0.1 (D) (D) (D) DCV
TR3 V/TR3 T27 0/PARK 0/PARK 1.7/OD 1.7/OD DCV/MODE
TR 4 T28 0 0 VBAT VBAT DCV
TFT (K) T29 0.5-2/210-110 0.5-2/210-110 0.5-2/210-110 0.5-2/210-110 DCV/DEG
ACCS PID OFF ON (A) OFF OFF OFF-ON
FLI (H) PID 50 50 50 50 %
GEAR PID 1 1 4 5 GEAR
LOAD PID (L) 15-28 19-26 30-40 %
RPM PID 0 750-820 1300-1520 1600-1780 RPM
VSS PID 0 0 30 55 MPH
ACTUATORS/OUTPUTS - 4.0L EXPLORER/MOUNTAINEER

Actuators/Outputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VSO B1 0 0 30 55 MPH
PATSTRT/SMC B2 0.1 0.5 0.5 0.5 DCV
FP B12 8.4 2.5 2.8 2.8 DCV
EVAPC V B13 VBAT/0 VBAT/0 VBAT/0 (R) VBAT/0 (R) DCV/%
ACCR (WAC) B14 VBAT/OFF 0.1/ON (A) VBAT/OFF VBAT/OFF DCV/OFF-ON
PCV HC E3 OFF OFF OFF OFF ON-OFF
EVMV E6 0 0 500-900 (F) 500-900 (F) mA
FANVAR E7 0 0/100 13 10 %
CDB (CYL 3 and 4) E12 VBAT VBAT VBAT VBAT DCV
CDC (CYL 2 and 6) E16 VBAT VBAT VBAT VBAT DCV
CDA (CYL 1 and 5) E17 VBAT VBAT VBAT VBAT DCV
TACM (+) E34 3.8 VBAT VBAT VBAT DCV
INJ2 E35 0 20.9-3.3 3.1-5.1 6-7 mS
INJ4 E36 0 20.9-3.3 3.1-5.1 6-7 mS
INJ6 E37 0 20.9-3.3 3.1-5.1 6-7 mS
HTR11 E49 0.1/OFF (O) 0.1/ON 0.1/ON 0.1/ON DCV/OFF-ON
HTR21 E50 0.1/OFF (O) 0.1/ON 0.1/ON 0.1/ON DCV/OFF-ON
TACM (-) E51 3.8 VBAT VBAT VBAT DCV
INJ1 E52 0 20.9-3.3 3.1-5.1 6-7 mS
INJ3 E53 0 20.9-3.3 3.1-5.1 6-7 mS
INJ5 E54 0 20.9-3.3 3.1-5.1 6-7 mS
EGRVR E63 VBAT/0 VBAT/0 0-VBAT/31 (T) 0-VBAT/49 (T) DCV/%
HTR11 E69 0.1/OFF (O) 0.1/ON 0.1/ON 0.1/ON DCV/OFF-ON
HTR21 E70 0.1/OFF (O) 0.1/ON 0.1/ON 0.1/ON DCV/OFF-ON
EPC T11 6.0 8.0 10.0 10.0 DCV
EPC2 T23 8.0 10.0 10.0 10.0 DCV
EPC3 T34 6.0 8.0 VBAT VBAT DCV
SSA (SS1) T42 0.1/ON 0.1/ON VBAT/OFF VBAT/OFF DCV/OFF-ON
SSB (SS2) T43 VBAT/OFF VBAT/OFF VBAT/OFF VBAT/OFF DCV/OFF-ON
SSC (SS3) T44 VBAT/OFF VBAT/OFF VBAT/OFF 0.1/ON DCV/OFF-ON
SSD (SS4) T45 0.1/ON 0.1/ON 0.1/ON 0.1/ON DCV/OFF-ON
TCC T46 VBAT/0 VBAT/0 VBAT/0 0.2/100 DCV/%
HTR12 T47 0.2/OFF (O) 0.2/ON 0.2/ON 0.2/ON DCV/OFF-ON
HTR22 T48 0.2/OFF (O) 0.2/ON 0.2/ON 0.2/ON DCV/OFF-ON
LONGFT1 PID (L) (-)20-(+)20 (-)20-(+)20 (-)20-(+)20 %
LONGFT2 PID (L) (-)20-(+)20 (-)20-(+)20 (-)20-(+)20 %
MIL PID OFF OFF OFF OFF OFF-ON
SHRTFT1 PID 0 (-)10-(+)10 (-)10-(+)10 (-)10-(+)10 %
SHRTFT2 PID 0 (-)10-(+)10 (-)10-(+)10 (-)10-(+)10 %
SPARKADV PID 10 13-25 26-35 21-35 DEG
TCIL PID OFF OFF OFF OFF OFF-ON
OTHER - 4.0L EXPLORER/MOUNTAINEER

Other PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
ETCVREF B4/B24/E66 5 5 5 5 DCV
VPWR B35/B36 VBAT VBAT VBAT VBAT DCV
VREF B40/E57 5 5 5 5 DCV
KAPWR B45 VBAT VBAT VBAT VBAT DCV
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.