Symptom Table - Climate Control Systems

2007 Ford Escape Base, 2.3 Z, FWD, AutomaticSECTION Symptom Table - Climate Control Systems
WARNING: This page is about a different car, the 2010 Mercury Milan and 2010 Ford Fusion. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: Some PCM DTCs may inhibit A/C operation. If any PCM DTCs are retrieved, diagnose those first. Refer to PCM DTC TABLE .
SYMPTOM TABLE - CLIMATE CONTROL SYSTEMS

Condition Possible Sources Action
  • No communication with the HVAC module
  • Fuse(s)
  • Circuitry open
  • HVAC module communication network
  • Unable to duplicate the customer concern and no DTCs present
  • HVAC system and/or related components
  • Incorrect/erratic function in AUTO mode
  • Circuitry open/shorted
  • In-vehicle temperature/humidity sensor
  • HVAC module
  • Reduced outlet airflow
  • Cabin air filter
  • Air Conditioning Compressor Module (ACCM)
  • Evaporator discharge air temperature sensor
  • Blower motor
  • Blower motor control
  • PCM
  • If the airflow is reduced only when in AUTO, A/C, MAX A/C, defrost or defrost/floor modes, Go To PINPOINT TEST J .
  • If the airflow is reduced in all modes, INSPECT the cabin air filter. If the cabin air filter is clean and free of damage and debris, Go To PINPOINT TEST L .
  • The air inlet door is inoperative
  • Circuitry open/shorted
  • Door actuator
  • Air inlet door binding or stuck
  • HVAC module
  • Incorrect/erratic direction of airflow from outlets
  • Circuitry open/shorted
  • Door actuator
  • Mode door binding or stuck
  • HVAC module
  • Insufficient, erratic or no heat
  • Low engine coolant level
  • Engine overheating
  • Plugged or partially plugged heater core
  • Temperature blend door is binding or stuck
  • Temperature blend door actuator
  • Heater hose is kinked or binding
  • The air conditioning (A/C) is inoperative
  • A/C pressure transducer
  • Evaporator discharge temperature sensor
  • HVAC module
  • PCM
  • FCIM 
  • ACM 
  • ACCM 
  • The air conditioning (A/C) is always on
  • Evaporator discharge temperature sensor
  • HVAC module
  • PCM
  • FCIM 
  • ACM 
  • ACCM 
  • Temperature control is inoperative/does not operate correctly
  • Circuitry open/shorted
  • HVAC module
  • Temperature blend door is binding or stuck
  • Temperature blend door actuator
  • The blower motor is inoperative
  • Fuse(s)
  • Circuitry short/open
  • Blower motor relay
  • A/C blower motor
  • HVAC module
  • A/C blower motor speed control
  • The blower motor does not operate correctly
  • Circuitry open/shorted
  • A/C blower motor speed control
  • HVAC module
  • The dual temperature control is inoperative/does not operate correctly
  • Temperature blend door/actuator broken/binding
  • HVAC module - Electronic Automatic Temperature Control (EATC)
  • Low A/C refrigerant charge
NOTE: For the passenger side temperature setting on hybrid vehicles equipped with dual-zone Electronic Automatic Temperature Control (EATC) and a Front Controls Interface Module (FCIM) built on or after 4/08/2009 to be functional, a passenger must be seated in the front passenger seat. If the front passenger seat is not occupied, the HVAC module will control the system based only on the driver side temperature setting. The HVAC module receives a Medium Speed Controller Area Network (MS-CAN) signal from the FCIM  to indicate if the front passenger seat is occupied.
CHECK that the A/C system pressure is above 290 kPa (42 psi). If the pressure is below 290 kPa (42 psi), REFER to CLIMATE CONTROL SYSTEM . CHECK the temperature blend doors/actuators for a binding or broken condition. If no condition is found, INSTALL a new HVAC module.
  • The temperature display will not switch between Celsius and Fahrenheit
  • HVAC module
  • Inaccurate external temperature display
  • HVAC module
  • Ambient temperature sensor
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.