Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
SYS.OK|MANUAL.DB● LIVE
HOMESERVICE MANUALSFORD2004FREESTAR V6-4.2L VIN 2REPAIR AND DIAGNOSISWINDOWS AND GLASSWINDOWSTESTING AND INSPECTIONPINPOINT TESTSTESTS AL
2004 Ford Freestar V6-4.2L VIN 2
Tests AL
2004 Ford Freestar V6-4.2L VIN 2SECTION Tests AL
PINPOINT TEST AL: LEFT OR RIGHT POWER VENT WINDOW IS INOPERATIVE



Normal Operation
12 volts are supplied from the BEC fuse 10 (30A) to the accessory delay relay 1 on circuit 296 (WH/VT). When energized by the SJB, the accessory delay relay 1 then supplies 12 volts to the quarter window switch on circuit 194 (PK). When the quarter window switch is pressed in the OPEN position, 12 volts are supplied to RH and LH quarter window motors on circuit 882 (BN/YE). Ground is supplied on circuit 881 (BN), through the quarter window switch, then on circuit 1205 (BK). When the quarter window switch is pressed in the CLOSE position, 12 volts are supplied to the RH and LH quarter window motors on circuit 881 (BN). Ground is supplied on circuit 882 (BN/YE), through the quarter window switch, then on circuit 1205 (BK).
Possible Causes
- circuit 881 (BN) open
- circuit 882 (BN/YE) open
- quarter window motor
Test AL1-AL2:
Test AL2-AL4:
Test AL5:
Normal Operation
12 volts are supplied from the BEC fuse 10 (30A) to the accessory delay relay 1 on circuit 296 (WH/VT). When energized by the SJB, the accessory delay relay 1 then supplies 12 volts to the quarter window switch on circuit 194 (PK). When the quarter window switch is pressed in the OPEN position, 12 volts are supplied to RH and LH quarter window motors on circuit 882 (BN/YE). Ground is supplied on circuit 881 (BN), through the quarter window switch, then on circuit 1205 (BK). When the quarter window switch is pressed in the CLOSE position, 12 volts are supplied to the RH and LH quarter window motors on circuit 881 (BN). Ground is supplied on circuit 882 (BN/YE), through the quarter window switch, then on circuit 1205 (BK).
Possible Causes
- circuit 881 (BN) open
- circuit 882 (BN/YE) open
- quarter window motor
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.