Description of OBD II Drive Cycle

2004 Ford Focus ZX5, 2.3 Z, StandardSECTION Description of OBD II Drive Cycle

The following procedure is designed to execute and complete the OBDII monitors and to clear the Ford P1000, I/M readiness code. To complete a specific monitor for repair verification, follow steps 1 through 4, then continue with the step described by the appropriate monitor found under the "OBDII Monitor Exercised" column. When the ambient air temperature is outside 4.4 to 37.8Β°C (40 to 100 Β°F), or the altitude is above 2438 meters (8000 feet), the EVAP monitor will not run. If the P1000 code must be cleared in these conditions, the PCM must detect them once (twice on some applications) before the EVAP monitor can be "bypassed" and the P1000 cleared. The EVAP "bypassing" procedure is described in the following drive cycle.

The OBDII Drive Cycle will be performed using a scan tool. Consult the instruction manual for each described function.

NOTE: A detailed description for clearing the DTCs is found in this article. Refer to CLEAR THE CONTINUOUS DIAGNOSTIC TROUBLE CODES (DTCS) AND RESET THE EMISSION MONITORS INFORMATION IN THE POWERTRAIN CONTROL MODULE (PCM)Β .
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.